Proprietary notice The information presented in this guide is the property of SAF Tehnika, JSC. No part of this document may be reproduced or transmitted without proper permission from SAF Tehnika, JSC. The specifications or information contained in this document are subject to change without notice due to continuing introduction of design improvements.
System Configuration Password configuration........... 58 System Configuration System configuration ..........59 System Configuration System services ............61 System Diagnostic Loopback configuration ..........63 System Diagnostic Download troubleshooting file ........64 SAF Tehnika JSC...
Page 4
RSSI/audio port ....................77 Appendix A: TECHNICAL SPECIFICATION ............. 79 Integra-W preliminary RSL Threshold (dBm) and Link Capacity (Mbps)..80 Maximum Tx Power for Integra-W and Integra-WS ..........80 High Performance integrated antenna specification ..........81 CONTACTS ......................81 SAF Tehnika JSC...
Please note that frequency range is set from the central frequency of the first 3.5 MHz channel to the central frequency of the last 3.5 MHz channel (see the diagram below). Frequency range of subband B low side Integra-W 38 GHz FODU: SAF Tehnika JSC...
Compared to the ICNIRP restrictions, FCC CFR 47 specifies the Maximum Permissible Exposure (MPE) levels for occupational/controlled environment and general public/uncontrolled environment, as shown in the table below. FCC MPE limits within the frequency range 1.5-100 GHz SAF Tehnika JSC...
Page 7
´Sicherheit in elektrischen, magnetischen und elektromagnetischen Feldern, ´Teil 2: Schutz von Personen im Frequenzbereich von 30 kHz bis 300 GHz´ - ENV 50166-2, January 1995 (withdrawed in December 1999 by CENELEC) ´Human Exposure to Electromagnetic Fields (10 kHz – 300 GHz)´ SAF Tehnika JSC...
Three M8x1.25x16 hex flange bolts already attached to clamps for housing and pipe [5] One hex flange bolt M8x1.25x30, one M10x1.5 hex flange nut and one M8x80 eye screw already attached to clamps for housing and pipe [5] One M8x80 eye screw SAF Tehnika JSC...
14 Grounding flange nut Numbers of mounting bracket and Integra FODU parts in next sections will be mentioned in square brackets []. Changing polarization of Integra-W FODU and antenna Tools required: 13mm (0.512”) wrench (comes in package) SAF Tehnika JSC...
5mm. When polarization is changed, make sure that drain hole cap located at grounding flange nut should be removed and inserted in previous drain hole. Assembly procedure Tools required: 13mm (0.512”) wrench (comes in package) SAF Tehnika JSC...
Page 11
∅ 25..75mm. hex flange nut. Hex flange nuts should be evenly aligned on View of assembled mounting bracket on the mast threaded bolts so that mounting bracket clamp pole. [9] is tightly attached to the pipe. Tighten hex SAF Tehnika JSC...
Page 12
- hex bracket: left side screw on Integra-W FODU flange nuts and bolts of azimuth and elevation and two hex flange bolts between both eye screws, right side screw on Integra-W mounting bracket clamps for housing and SAF Tehnika JSC...
Page 13
Integra-W FODU and hex flange bolt mounting bracket clamps for housing and pipe on azimuth angle indicator with torsion 20..25 with torsion 20..25 N·m. N·m. SAF Tehnika JSC...
Page 14
INTEGRA-W/INTEGRA-WS User Manual INSTALLATION SAF Tehnika JSC...
Using size 5 allen wrench loosen one clamp place and the adapter flange fits into the completely and second clamp by a half-turn. Integra-WS transition flange socket. Note! Protective sticker should be removed before attaching the Integra-WS FODU to the antenna. SAF Tehnika JSC...
Page 16
Secure the position of the Integra-WS by fully tightening both fixation clamps. For extra protection from sun radiation it is recommended to install sun shield to cover the radio If any further assistance is required please contact techsupport@saftehnika.com SAF Tehnika JSC...
(left – Integra-W conduit. direction, right – CPE direction). Tighten parts on both ends of the conduit. Fasten Connect LC connector to SFP module. other end of fiber conduit to the pole using included tie-wrap. Assembled view. SAF Tehnika JSC...
Accepted input voltage 24…60VDC. Output voltage is stabilized to 54VDC. Interconnection scheme with Integra / Integra-S / Integra-W / Integra-WS / SAF FreeMile 5 GE / SAF FreeMile 17 / SAF FreeMile 24 / CFIP-106 / CFIP-108: SAF Tehnika JSC...
Page 19
In case classified PoE mode is enabled (S1 position DOWN, S4 position UP) I mode (PD class) is negotiated automatically with the FODU. Position of DIP switches should be changed only while PoE injector is turned off. SAF Tehnika JSC...
Page 20
Output Voltage 54 V Max Current 1.2 A (24…36V DC), 1.6 A (36…60V DC) Power Connector 2ESDV-02P with screw locks Ethernet Connectors Shielded RJ45 jacks Data Lines Pins (1, 2), (3, 6), (4, 5) and (7, 8) SAF Tehnika JSC...
Ethernet management connection configuration Before proceeding with initial link setup in Web GUI, you must adjust IPv4 settings of your LAN adapter to 192.168.205.0 subnet. IP address should be other than default low/high side IP addresses (192.168.205.10/192.168.205.11). SAF Tehnika JSC...
192.168.205.11 for high side Integra-W/Integra-WS FODU (P/N D*******H*) • For secure connection use https:// prefix. 2. Press “Enter” key. 3. Login screen will appear. 4. Enter username and password. Default credentials are as follows: Username: admin • Password: changeme • SAF Tehnika JSC...
“Switch to secure connection (HTTPS)” indicates that HTTP protocol is being used. Press on the link and you will be redirected to secure HTTPS URL. Main page After login you will be automatically redirected to the Main page of Web GUI: SAF Tehnika JSC...
Values appear in orange colour in case alarm threshold values were exceeded during last 15 seconds. Modifying basic system parameters In order to proceed with initial configuration, press MODIFY button and entry fields will appear for adjustable values: SAF Tehnika JSC...
Page 25
Allows choosing whether only FCC, ETSI or both channel bandwidth options are visible in “Configuration” selection field. Bandwidth Allows choosing between available channel bandwidth options along with indication of fixed modulation or maximum modulation for ACM, bandwidth standard ETSI or FCC. SAF Tehnika JSC...
Pressing „Execute for both” applies changes made to the corresponding section both for local and remote side Integra-W/Integra-WS FODUs. Over The Air Over The Air Radio Configuration Radio configuration page is available in “System” menu (Over The AirRadioConfiguration). Status mode Press button. SAF Tehnika JSC...
Page 27
5) RSSI LED – Indicates whether RSSI LED is enabled or disabled (status mode); allows disabling or enabling RSSI LED operation (modify mode). By default RSSI LED is enabled. Please refer to RSSI LED section for further details. SAF Tehnika JSC...
Page 28
Use to check radio software version Use to check status of ATPC (Automatic Transmit Power radio atpc status Control). radio atpc state Use to enable/disable ATPC. <enable|disable> radio atpc delay <1..5> Use to define ATPC update period. SAF Tehnika JSC...
1522B. By pressing „Execute configuration” changes made to the corresponding section apply only for the local side Integra-W/Integra-WS. If „Rollback on” is selected, configuration will be reverted in case erroneous configuration changes are applied. SAF Tehnika JSC...
CLI commands (System Tools Console) network port show info Use to show status of all ports. network port show config Use to show configuration of all ports. SAF Tehnika JSC...
Alarm entries are mostly distributed in two groups – “Set”’ when alarm appears and “Reset” when alarm disappears. You also have fast access to alarm filtering, where it is possible to choose which alarm groups you are willing to filter out of all log entries. SAF Tehnika JSC...
Page 32
INTEGRA-W/INTEGRA-WS User Manual WEB GUI Status mode Press button. SAF Tehnika JSC...
Page 33
Use to show entries for a specific sensor. Regarding <sensor> <last|time> subcommands “last” and “time” refer to commands above. <#_of_entries|time> log event show module <modem|ns|psu|radio|system> Use to show entries for a specific module. Regarding <last|time> subcommands “last” and “time” refer to commands above. <#_of_entries|time> SAF Tehnika JSC...
(filter). Performance Alarm Sensor configuration Following section allows specifying behaviour of available sensor parameters. It is not recommended to add “License remaining time” sensor parameter to performance (“perfd”) type parameters. Status mode Press button. SAF Tehnika JSC...
Page 35
5) Set all to default – Restores default settings for all groups and sensors. 6) By pressing „Execute configuration” changes made to the corresponding section apply only for the local side Integra-W/Integra-WS. If „Rollback on” is selected, configuration will be reverted in case erroneous configuration changes are applied. SAF Tehnika JSC...
Page provides summary of parameters’ alarm thresholds. All thresholds are predefined and some change dynamically according to system configuration. Thresholds can be modified if required. Alarm activates when current value exceeds low-delta or high+delta values. Alarm deactivates when current value exceeds low+delta or high-delta values. SAF Tehnika JSC...
Page 37
INTEGRA-W/INTEGRA-WS User Manual WEB GUI Status mode Press button. Modify mode SAF Tehnika JSC...
By default Rx level (dBm) and Radial MSE (dB) are selected. Sensor Configuration Not all sensors available in can be displayed in Performance graph. MODIFY button is deactivated in Performance graph page. SAF Tehnika JSC...
Page 39
4) Indicates start and end date/time of period displayed and allows selecting specific period to show. 5) Period length – Indicates length of currently displayed period. 6) Get data – Press to apply selected time interval changes. 7) Left and right sliders allow to “zoom” currently selected time period. SAF Tehnika JSC...
6) Download XML – Press to download performance log in a extensible markup language (.xml) file. CLI commands (System Tools Console) log perf show Use to show specified number of last performance log <1M|15M|60M> last entries with specified sensor log step. <1…1440> SAF Tehnika JSC...
Use to show entries from a certain time point. Following log perf show formats are supported: YYYY-MM-DD/hh:mm:ss; MM- <1M|15M|60M> time <time> DD/hh:mm:ss; MM-DD/hh:mm; hh:mm:ss; hh:mm log perf clear Use to clear performance log. Performance Ethernet Ethernet switch statistics SAF Tehnika JSC...
Page 42
WEB GUI Status mode Press button. Modify mode (buttons appear at the bottom of the page) Statistics for – time during which statistics have been gathered; Rx detected – The total number of packets detected on port’s ingress; SAF Tehnika JSC...
Page 43
Note that this does not include multicast packets; 29) Rx Multicast frames – The total number of good packets received that were directed to a multicast address. Note that this number does not include packets directed to the broadcast address; SAF Tehnika JSC...
Page 44
52) Tx Carrier errors – A Number of frames transmitted in which the carrier signal was lost or in which the carrier signal was not present 53) Tx Collisions – The total number of collisions experienced by this port during packet transmissions SAF Tehnika JSC...
Auto refresh – Allows disabling auto refresh of constellation/spectrum; Automatic clear interval – Allows choosing how often is constellation automatically cleared; Quadrant view – Allows zooming constellation diagram to specific quadrant or part of the quadrant; SAF Tehnika JSC...
Page 46
8QAM or 4QAM. It displays the signal as a two-dimensional scatter diagram in the complex plane at symbol sampling instants. Measured constellation diagram can be used to recognize the type of interference and distortion in a signal. Constellation diagram (512QAM): Examples of Integra-W/Integra-WS constellation diagrams under ideal conditions are shown below: SAF Tehnika JSC...
Page 47
For the purpose of analysing the received signal quality, some types of corruption are evident in the constellation diagram. For example: 1) Gaussian noise is displayed as fuzzy constellation points: 2) Non-coherent single frequency interference is displayed as circular constellation points: SAF Tehnika JSC...
Page 48
Signal appearance will depend on configured channel bandwidth. Measured spectrum curve can be used to recognize in-band interference or very powerful out-band interference (due to filters applied). Spectrum (80MHz): SAF Tehnika JSC...
Page 49
INTEGRA-W/INTEGRA-WS User Manual WEB GUI Examples of Integra-W/Integra-WS spectrum curves in various channel bandwidths: SAF Tehnika JSC...
5) Choose File – Press to browse for a firmware file on your hard disk drive. 6) Upload – Press to upload a firmware file to Integra-W/Integra-WS. CLI commands (System Tools Console) firmware info [<version>] Use to show detailed information on current or specific Integra-W/Integra-WS firmware. SAF Tehnika JSC...
“toggle” forces to set other bank than the running one, “fs” is factory defined emergency bank, which is used if both “fw1” and “fw2” fail. System Configuration IP configuration IP address configuration page is available in “System” menu (SystemConfigurationIP configuration). Status mode Press button. SAF Tehnika JSC...
<IP_address> Use to ping an IP address. System Configuration SNMP configuration The SNMP configuration pages provide configuration of SNMP communities, host and trap addresses. SAF NMS system will work only when SNMP is properly configured. SAF Tehnika JSC...
Page 53
INTEGRA-W/INTEGRA-WS User Manual WEB GUI Relevant MIB files can be downloaded directly from Integra(-S) Web GUI. See (7) below. Status mode Press button. SAF Tehnika JSC...
Page 54
Integra-W/Integra-WS. If „Rollback on” is selected, configuration will be reverted in case erroneous configuration changes are applied. CLI commands (System Tools Console) snmp manager [add|del <IP>] Use to check, add or delete IP addresses of SNMP v1/v2c SAF Tehnika JSC...
Use to check, set or delete IP addresses of SNMP v2c trap [set|del <IP>] managers. snmp showconfig active Use to check currently active SNMP configuration. snmp showconfig stored Use to check saved SNMP configuration. System Configuration Configuration file SAF Tehnika JSC...
Page 56
INTEGRA-W/INTEGRA-WS User Manual WEB GUI Status mode Press button. Modify mode SAF Tehnika JSC...
Page 57
Use to load uploaded system configuration. If no configuration was uploaded via Web GUI, command will configuration load restore saved configuration, thus discarding unsaved changes. configuration status Use to check whether running configuration is saved. configuration store Use to save running configuration. SAF Tehnika JSC...
Use to show information on current user. system user mgmt <username> Use to set read (“r”) or write (“w”) access right for access <r|w> particular <username>. system user mgmt <username> Use to delete particular <username>. “admin” user delete cannot be deleted. SAF Tehnika JSC...
Use to reset user to factory defaults. system password change Use to change password for current user. <password> system password reset Use to reset all passwords to default. System Configuration System configuration Status mode Press button. SAF Tehnika JSC...
Page 60
Use to enable or disable NTP client. system ntp server add Use to add an IP address of a NTP server. <IP_address> system ntp server remove Use to remove an IP address of a NTP server. <IP_address> SAF Tehnika JSC...
Use to clear list of NTP servers. system ntp timezone <-12:00 ... Use to specify GMT timezone. 14:00> User to force system to obtain the time from a NTP system ntp sync server. System Configuration System services Status mode Press button. SAF Tehnika JSC...
Page 62
10) Confirm RADIUS password – Allows confirming RADIUS password. 11) Hide password - Uncheck to display entered password in plaintext. 12) By pressing „Execute configuration” changes made to the corresponding section apply only for the local side Integra-W/Integra-WS. SAF Tehnika JSC...
(values should not be coloured in red). When loopback is activated, “Loopback duration time” countdown timer will appear. 2) By pressing „Execute configuration” changes made to the corresponding section apply only for the local side Integra-W/Integra-WS. Below is an example of Main status page during modem loopback: SAF Tehnika JSC...
Use to disable modem loopback. System Diagnostic Download troubleshooting file Clicking on the link will download troubleshooting file archive package to your hard disk drive (“Downloads” folder of your browser). Contents: SAF Tehnika JSC...
Information on system configuration including Web services, System.html RADIUS, IP address, user, NTP configuration and inventory info System Tools License management Provides list of available licenses, time left for each license and license upload controls. Status mode Press button. SAF Tehnika JSC...
Page 66
Use to list available license files. license file add <filename> Use to add uploaded license file to license file list. license file activate <filename> Use to activate license file. license file deactivate <filename> Use to deactivate license file. SAF Tehnika JSC...
List of valid CLI commands can be found at the end of each Web GUI page description. Refer to Chapter 4: COMMAND LINE INTERFACE for details how to connect to other CLI interfaces (serial, SSH, Telnet). System About About System Provides short description of Integra-W/Integra-WS series products. SAF Tehnika JSC...
INTEGRA-W/INTEGRA-WS User Manual WEB GUI CLI commands (System Tools Console) product info Use to show detailed information on Integra-W/Integra- WS FODU. system number Use to show Integra-W/Integra-WS serial number. System About Copyright Displays copyright information. SAF Tehnika JSC...
Below are connection steps with PuTTY - Windows freeware software. 1. Open PuTTY and go to “Serial” category. Specify your COM port number you will be using, change “Speed (baud)” to “115200” and “Flow control” to “None”: SAF Tehnika JSC...
Page 71
3. Enter username and password. Default credentials are as follows: login: admin • password: changeme • 4. After successful login “SAF>” prompt should appear (if system name is default, otherwise prompt will differ): 5. Press “Ctrl+C” to log off from current session. SAF Tehnika JSC...
Telnet connection to Integra-W/Integra-WS FODU is carried out using Ethernet management connection. Please refer to Chapter “Ethernet management connection configuration” for Ethernet management port connection details. You can use any Telnet client. Below are connection steps with PuTTY - Windows freeware software. SAF Tehnika JSC...
Page 73
(“23” by default):correct port number is used (“23”correct port number is used (“23” by default) 2. Press “Open”, enter login credentials (default user name is admin and password - changeme). After successful login following prompt should appear: SAF Tehnika JSC...
INTEGRA-W/INTEGRA-WS User Manual TOOLS Chapter 5: TOOLS MIB files Relevant MIB files can be downloaded directly from Integra-W/WS Web GUI. See Chapter “System Configuration SNMP configuration” for further details. SAF Tehnika JSC...
RSSI LED can be activated in three operational modes – Mode 1, Mode 2 and Mode 3. By default RSSI LED is enabled in Mode 1. For further details please refer to Radio configuration page. Corresponding Rx signal levels and LED blinking pattern for each mode is represented in the figure below: SAF Tehnika JSC...
The following charts and tables show typical relationship of the received signal level (Rx level) displayed by Integra-W/Integra-WS vs. RSSI port output voltage (RSSI – Received Signal Strength Indicator) and audio frequency. The RSSI port is located on FODU. The evaluated Rx level has the error +/-2 dB. SAF Tehnika JSC...
Page 78
INTEGRA-W/INTEGRA-WS User Manual INTERFACES Output voltage Rx level RSSI (dBm) voltage (V) Audio Output audio frequency level frequency (dBm) (Hz) -100 1000 SAF Tehnika JSC...
292 x 176 x 250 mm / 11.5” x 7” x 10” max Pole size Ø 40 – 120 mm / Ø 1.6” – 4.7” Mount on antenna Weight 2.55 kg / 5.6 lbs * Inquire SAF representative for more information SAF Tehnika JSC...
Class 3 37.5 2.4° 62.5 Class 3 38.2 Class 3 39.1 1.9° 64.5 Class 3 41.4 1.6° 66.5 Class 3 0.6m 41.6 Class 3 41.6 Class 3 45.2 Class 3B Class 3 6GHz, 11GHz Integra Integra-WS CONTACTS SAF Tehnika JSC...
Page 82
SAF Tehnika JSC 24a, Ganibu dambis, Riga, LV-1005, Latvia, EU sales@saftehnika.com www.saftehnika.com...