Advertisement

Quick Links

GridBee GF10000PW
Owner's Manual
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com
O&M_GF10000PW_10499_20200615

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Medora GridBee GF10000PW and is the answer not in the manual?

Questions and answers

Summary of Contents for IXOM Medora GridBee GF10000PW

  • Page 1 GridBee GF10000PW Owner's Manual © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com O&M_GF10000PW_10499_20200615...
  • Page 2: Table Of Contents

    Customer Service About Ixom Ixom combines knowledge and experience from across the water quality spectrum to help solve real-world problems. Whether in Lakes, Stormwater Retention Ponds, Raw Drinking-Source Reservoirs, Water Treatment Plants, Potable Storage Tanks, or Wastewater Treatment Processes, Ixom equipment continues to be at the forefront as the #1 world leader for in-situ water body treatment.
  • Page 3: Safety

    Most accidents can be avoided by using common sense and concentration on the job being done. Carefully read safety information when you see any safety symbols. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 1949_10036_20200528 O&M_GF10000PW_10499_20200615 - 1...
  • Page 4 CAUTION: EDGES MAY BE SHARP AND CAUSE WARNING: ICE SURROUNDING MACHINE MAY LACERATION IF PROPER CARE IS NOT USED. NOT SUPPORT WEIGHT, KEEP CLEAR OF THIN ICE. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 1949_10036_20200528 O&M_GF10000PW_10499_20200615 - 2...
  • Page 5 "OFF" position. The On/Off switch is to be by OSHA. used as the emergency stop. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 1949_10036_20200528 O&M_GF10000PW_10499_20200615 - 3...
  • Page 6: Operation

    The motor and impeller is designed to operate at the same full speed as the solar-powered SolarBee models. Flow Coming Off Distribution Dish © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10181_20200326 O&M_GF10000PW_10499_20200615 - 4...
  • Page 7: Site Preparation

    © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10153_20200220 O&M_GF10000PW_10499_20200615 - 5...
  • Page 8: Features

    The GridBee will not rotate when it is anchored using the tether system. Tethering System © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10302_20200326 O&M_GF10000PW_10499_20200615 - 6...
  • Page 9 The connectors are indexed to prevent Durable Wiring And Connectors improper wiring. A general electrical schematic can be found in the Maintenance and Field Adjustment section. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10165_20200528 O&M_GF10000PW_10499_20200615 - 7...
  • Page 10 The upper Lower Coupling coupling remains attached to the brushless motor while the lower coupling and coupling sleeve remain on the impeller shaft. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10165_20200528 O&M_GF10000PW_10499_20200615 - 8...
  • Page 11 The impeller bushing is a smooth collar that the Impeller impeller shaft tip fits into. The impeller bushing aligns Bushing and centers the impeller shaft within the machine. Block Impeller Hub © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10165_20200528 O&M_GF10000PW_10499_20200615 - 9...
  • Page 12 2 in to 2 1/2 in (5.1 cm to 6.4 cm) 10000 2 in to 2 1/2 in (5.1 cm to 6.4 cm) © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10165_20200528 O&M_GF10000PW_10499_20200615 - 10...
  • Page 13 Hose and Intake Box Configuration - MODEL MAY VARY SB2500PW SB5000PW - GF5000PW SB10000PW - GF10000PW © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10165_20200528 O&M_GF10000PW_10499_20200615 - 11...
  • Page 14 2 in to 2 1/2 in (5.1 cm to 6.4 cm) 10000 2 in to 2 1/2 in (5.1 cm to 6.4 cm) © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10165_20200528 O&M_GF10000PW_10499_20200615 - 12...
  • Page 15 • Avoid being crushed by ice pressure. • Provide extra buoyancy when needed without going much deeper into the water. Float © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10165_20200528 O&M_GF10000PW_10499_20200615 - 13...
  • Page 16: Assembly

    STEP 4: Place the Impeller Assembly off to the side and re-insert the Clevis Pin and Hair Pin into the Upper Coupling for safe keeping. Impeller Assembly Removal Motion © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 14...
  • Page 17 STEP 2: Place clevis pin back through upper shaft Impeller Assembly Reinsertion Motion coupling and secure with hair pin. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 15...
  • Page 18 STEP 6: Repeat Steps 1 through 5 for the other two floats. NOTE: The float plate may not be used on one of the three floats. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 16...
  • Page 19 SB10000 WITH 15FT (4.5m) OR LESS HOSE SB 7500 20FT (4.5m) OR LESS HOSE ALL SB5000 ALL SB2500 ALL POTABLE WATER UNITS ALL HIGH SALINITY (SALTWATER) APPLICATIONS © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 17...
  • Page 20 Use a two 19mm wrenches to tighten nut. STEP 5: Repeat steps 2 and 3 for the other 2 float arms. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 18...
  • Page 21 M12 90mm Bolt and tighten the Nylok nut. STEP 6: Repeat steps 2 through 5 for each turnbuckle assembly. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 19...
  • Page 22 13mm wrenches. STEP 5: Repeat steps 3 and 4 for the other 2 chain brackets. Applying Anti-Seize To The Bolts © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 20...
  • Page 23 Attaching Leg Extension With a Clevis Pin the machine can rest on. Securing Clevis Pins Secured with Hair pins © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 21...
  • Page 24 STEP 6: Tighten all 8 bolts/nuts using 13mm wrench and socket wrench. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 22...
  • Page 25 STEP 4: Fasten opposite end of the hose assembly to the intake box using four M8 x 20mm bolts. STEP 5: Fasten the two intake box tubings using two M8 x 45mm bolts on each tube. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528...
  • Page 26 Equipment Assembly Injection Hose Assembly © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 24...
  • Page 27 This will avoid damage to the motor controller and motor. Kellem Grip Connection Point © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 458_10264_20200528 O&M_GF10000PW_10499_20200615 - 25...
  • Page 28: Maintenance

    To turn the Machine motor off, turn the On / Off switch to the off position. To completely power down the digital controller, remove all power sources in the proper sequence. DIGITAL CONTROLLER © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10237_20200220 O&M_GF10000PW_10499_20200615 - 26...
  • Page 29 Once the air is released, the hose WARNING COULD LEAD TO SINKING THE will lower down into place. MACHINE, OR CAUSE SERIOUS INJURY! © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10263_20200220 O&M_GF10000PW_10499_20200615 - 27...
  • Page 30 STEP 4: Double check dish level at all three locations 2500 and fine tune as necessary. Dish Depths For Different Models of machines © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10422_20200220 O&M_GF10000PW_10499_20200615 - 28...
  • Page 31 DIVIDED BY Minute (RPM) # Seconds Expired RPM = (30 revolutions X 60) / (30 seconds) = 60 Impeller Rotational Speed = 60 RPMs © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10413_20200220 O&M_GF10000PW_10499_20200615 - 29...
  • Page 32 To completely power SWITCH down the digital controller, remove all power sources in the proper sequence. DIGITAL CONTROLLER © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10139_20200529 O&M_GF10000PW_10499_20200615 - 30...
  • Page 33 Please follow the proper procedure earlier in this section. Machine resting on floor ready for water. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 2088_10252_20200528 O&M_GF10000PW_10499_20200615 - 31...
  • Page 34 Please contact Ixom Customer Service: 1-866-437-8076 (customerservice@solarbee.com), for a quote for temporary removal of your machine. Hose properly layed out on tank floor. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 2088_10252_20200528 O&M_GF10000PW_10499_20200615 - 32...
  • Page 35: Electrical

    GRID POWER ONLY 120VAC 60HZ @ 2.0 AMPS ON SHORE / OUTSIDE RESERVOIR ON MIXER / INSIDE RESERVOIR BRUSHLESS DC MOTOR MOTOR CONTROLLER © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 1927_10299_20200326 O&M_GF10000PW_10499_20200615 - 33...
  • Page 36: Technical Specifications

    Removable assembly with easy access to impeller and impeller shaft. Electrical Requirements - Requires single phase 120VAC / 60Hz / 15 Amp Service. (Not supplied by Ixom.) Wiring Controls - Corrosion-resistant industrial cord with molded watertight indexed connectors. Low voltage in reservoir. Includes power box which converts single-phase AC voltage to low voltage DC power.
  • Page 37: Troubleshooting

    ELECTRONIC CONTROL BOX. A SWITCH IS NECESSARY TO KILL ALL AC GRID POWER INTO THE ELECTRONIC CONTROL BOX IF THERE BECOMES A NEED TO PERFORM ANY TYPE OF SERVICE INSIDE THE ELECTRONIC CONTROL BOX. © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 10300_20200528 O&M_GF10000PW_10499_20200615 - 35...
  • Page 38 AC GRID POWER AC GRID POWER AC GROUND (Green) AC GROUND (Green) AC GROUND (Green) © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 45 VDC SUPPLY TO 45 VDC SUPPLY TO 45 VDC SUPPLY TO GRIDBEE UNIT...
  • Page 39 BEHAVIOR VISUAL INDICATION BLINKS IN SUCCESSION FOUR (4) RED BLINKS HEALTHY SYSTEM SINGLE BLINK RED, Brain Board CUSTOMIZED YELLOW, AND GREEN SYSTEM BOOT UP SD Card SOLID BLUE Blinking SD CARD INSERTED Slot LED’s 10 BLINKS, RED, YELLOW, INCOMPLETE SD AND GREEN AT ONCE CARD UPDATE YELLOW GREEN...
  • Page 40: Parts Diagram

    Motor Control Cord PN: 20014500 14” Brushless Motor PN: 26063610 36” x 10’ Hose, White, NSF 101284 Leg Extension Kit Below Top Deck © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 1660_10500_20200526 O&M_GF10000PW_10499_20200615 - 38...
  • Page 41: Dimension Drawing

    Dimension Drawing GF10000PW © 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | info@medoraco.com 1662_10502_20200526 O&M_GF10000PW_10499_20200615 - 39...
  • Page 42: Warranty

    Parts that are determined by Ixom to be defective in material or workmanship under normal use during the two year warranty period will be repaired or replaced. Any shipping charges that may apply are the responsibility of the customer.
  • Page 43: Customer Service

    OSHA to perform the necessary work to install or remove SolarBee and GridBee equipment, and are knowlegeable in the regulations and standards of OSHA. If you feel the need to service your SolarBee or GridBee circulation equipment, please contact Ixom's Customer Service Department at: +1 866 437 8076 ©...

Table of Contents