System Setting
4
1
2
6
5
3
Harware: 1.Calibration platform 2.Needle height calibration PIN 3.Needle height signal light
4.Vacuum suck cleaning needle 5.Left valve standby position plastic cup 6. Right valve standby
position plastic cup
H1 is left valve calibration:M0,M1,M3,M12,M15
H2 is right valve calibration:M7,M8,M9,M13,M16
Common point calibration:M2,M4,M5,M6,M10,M11,M14
M10_Laser Z axis height detection base
When to use:Working position and actual position's height detection point is different
3
2
1
5

Advertisement

loading
Need help?

Need help?

Do you have a question about the 5701N and is the answer not in the manual?

Questions and answers

Marcial Barriga Jr.
July 22, 2025

how to convert the conveyor flow

Summary of Contents for Elite 5701N

  • Page 1 System Setting Harware: 1.Calibration platform 2.Needle height calibration PIN 3.Needle height signal light 4.Vacuum suck cleaning needle 5.Left valve standby position plastic cup 6. Right valve standby position plastic cup H1 is left valve calibration:M0,M1,M3,M12,M15 H2 is right valve calibration:M7,M8,M9,M13,M16 Common point calibration:M2,M4,M5,M6,M10,M11,M14 M10_Laser Z axis height detection base When to use:Working position and actual position’s height detection point is different...
  • Page 2 Select M10_Laser Z axis height detection base Open laser height detection interface Turn on laser bean Move X.Y. axis, align with customed target as right Pic. 1 Revise coordinate Pic. 1 M11_CCD alignment :M10 Laser Z axis height detection base When to use: Working position and actual position height detection point is different, Base height detection and actual height is different Select M11_CCD alignment:M10 Laser Z axis height detection base point...
  • Page 3 Pic. 1...
  • Page 4 H1 valve calibration:M0_Dispenser base When to use: Working dispense X.Y direction is wrong has an offset, renew needle and each axis hardware Select M0_Dispenser base ,Select H1_valve Move X.Y.Z as below Pic.1 Dispensing, dispense 1 drop as below Pic. 1 Revise coordinate Pic.
  • Page 5 H1 valve calibration:M1_CCD base align with M0 Dispenser base When to use :Working dispense X.Y direction has offset, renew needle and each axis hardware Select M1_CCD base align with M0:H1 dispenser base Turn on CCD light source Move X.Y axis, align with H1 dispenser glue output point as below Pic. 1 Revise coordinate...
  • Page 6 Pic. 1...
  • Page 7 H1 valve calibration :M3_Z axis base height: Touch auto searching surface When to use :Working dispense Z height has an offset, renew needle and each axis hardware Select M3_Z axis base height :touch auto searching surfac Move X.Y.Z axis, align needle with height detection PIN as right Pic.1 Revise coordinate Pic.
  • Page 8 4-1 Left needle will perform down 4-2 Detection needle height, height 4-3 System conversion, Z axis needle base needle height detection light off detection light on height, click YES update M3_Z axis height according to M3 coordinate 4-4 Laser height detection, perform 4-5 Left needle’s X.Y will move to M0 4-6 Dispense to calibration platform, can safety height detection to M0...
  • Page 9 Turn on light source, move X.Y axis . CCD align 4-6 amount position Adjust target size, adjust initial value to target size too Revise coordinate Red disk will show, left key to save system file H1 valve calibration:M12_cleaning point setting When to use : Renewing X.Y.Z axis hardware for example motor screw, cleaning position is wrong and therefore needs reset Select M12_H1 cleaning point setting...
  • Page 10 圖一 H2(spray valve)valve calibration:M7_Dispenser base When to use : Working dispense X.Y direction has an offset, renew and each axis hardware Select M7_Dispenser base Select H2_valve Move X.Y.Z axis as below Pic.1 Dispenser, Dispense one amount, showed at below Pic. 1 Revise coordinate...
  • Page 11 Pic. 1...
  • Page 12 H2(Spray valve)Valve calibration:M8_CCD base align with M7 dispenser point When to use :Working dispense X.Y direction has an offset, renew needle and each axis hardware Select M8_CCD base align with M0:H1 dispenser base Turn on CCD light source Move X.Y axis and align H1 glue output point as below Pic. 1 Revise coordinate...
  • Page 13 Pic. 1...
  • Page 14 H2(Spray valve)Valve calibration:M9_Z axis base height:touch auto searching surface When to use :Working dispense Z height has an offset, renew needle and each axis hardware. Specifies to valve calibration way Select M9_Z axis base height :touch auto searching surface Move X.Y.Z axis, align nut lead angle with height detection PIN as right Pic.1 Manually move needle until touches light off like Pic.
  • Page 15 Pic. 1 3-1 Right needle will perform down 3-2 Detect needle height, height needle height detection light off detection light ON according to M3 coordinate 5.6.8 Select M7_dispenser base, click CCD move to coordinate position Select M9_Z axis base height, click Z axis move down Click dispense(Dispense time will view the first dispense time in teach mode as base.) Select M8_CCD base align with M7 dispenser base Turn on light source, move X.Y axis, CCD align with glue amountposition...
  • Page 16 12. Red disk will show, click left key of mouse to save system file...
  • Page 17 H2 Valve calibration:M13_cleaning point setting When to use: Renew X.Y.Z axis hardware for example motor screw, Cleaning position is wrong which needs reset Select M13_H2 cleaning point setting Move X.Y.Z axis, align needle with vacuum suck cleaning needle as below Pic. 1 Click Vacuum clean Pin Revise Red disk will show up, click right mouse to save system file.
  • Page 18 Pic. 1...
  • Page 19 M2_machine XY Jig CCD origin When to use: Renew X.Y hardware for example motor screw and others, Working file base position move at fixed direction, Can use M2 coordinate to revise direction, and therefore can move all working files to correct position**Can only be use when all working filess moving is in fixed position *** Select M2_machine XY Jig CCD origin Turn on CCD light source...
  • Page 21 M4_machine repair point When to use: This position is set at a position that is easier to repair X.Y coordinate position M6_Conveyor belt standby point:Z>2000um stay here for vision alarm When to use: After finish every piece, wait at this coordinate for next piece, set it at plastic cup to prevent dropping while waiting M14 delay point setting, delay time1000ms will wait at this point When to use: Working point is written into delay point or move to this coordinate, delay point is used...
  • Page 22 Pic. 1 Pic. 2 Glue pressure adjustment hardware When to use: Impact glue output eamount Screw control box H1 is left valve watch, adjust Plastic needle size, impacts glue knob output amount Screw vale rotating speed, voltage control H2 is right valve watch , adjust Spray valve needle size, impacts knob glue output amount...
  • Page 23 H1_Glue amount test Step 1: Construct new program Cpk_H1_Point, check valve glue output Right mouse key Open New/Old working file Construct testing point glue amount program Provide glue pressure function button(No action for valve, used to adjust valve pressure) Start valve on(glue pressure on action + Valve on action 作) Single action dispense button(Single action on/off + glue pressure action + single action on/off valve action) Continue glue output button(Continue on glue pressure action + Continue on/off...
  • Page 24 3.Check if valve is clogged 4. Check if needle is clogged...
  • Page 25 H1_Construct dispenser testing working file Step 2:Construct base B0B1 coordinate Select base Turn on CCD light source Open conveyor belt interface Conveyor belt empty clamp Open connected PCBs interface CCD image move to Pic. 1 position, select B0 and B1 Cross size and target is the same Revise Close vision function...
  • Page 26 H1_Construct multi-dispense working point Step 3: Construct dispense point and array expand dispense working point Pic.2 Pic.3 Pic.4 Pic.1 Conveyor belt empty clamp, Pic. 1 Working point column, Pic. 1 Select teach, Pic. 1 Select dispense, Pic. 1 Input single dispense, stop seconds(initial 30ms start testing glue), Pic. 1 CCD move to dispense platform’s left up position, press F6 on keyboard or click new interface.
  • Page 27 H1_Auto dispense Step 4:Auto dispense 2 3 4 Conveyor belt empty clamp Auto (Actual feed in – clamp positioning – Dispense – Output) Auto Check(Dispense – Vision Confimation – Confirm dispense position and amout) Dry Run(Simulate actual route, No dispensing) View(Vision simulation of actual route) Run Button Start cycle + Start(When in auto, perform next step when everytime Start is pressed)
  • Page 28 H1_Dispense Test Save as new file, Construct dispense program, adjust glue parameter Pic.2 Pic.1 Pic.3 Pic.4 Pic.5 Dispense Conveyor belt clamp, Pic. 1 Right mouse key to use save as new file function, Construct Cpk_H1_Line Pic.1 Pic.3 Select Edit Pic.2 Input Start 1 to most 16 working point Pic.2 Delete all workingn points Pic.
  • Page 29 to 1500. Pic.5 Turn valve On delay, the shorter the negative value glue amount, the longer the positive value glue amount. Pic.5 Start valve On delay, the longer the negative value glue amount, the shorter the positive value glue amount. Pic.5 Adjust dispense parameter Target Size, Use needle size or dispense target setting as base Below interface parameter is screw valve dispense, can be used at needle valve and air pressure valve...
  • Page 30 Base Turn Valve On delay Right Pic. is performance under different delay. The lower the delay is, the more the turn anlge glue amount is -100 Base Dispense End distance Right Pic. is different end glue distance. The larger the distance is, the more the end 1500 part glue amount is...
  • Page 31 Firing Pin rotates downward to the end, Adjust spray valve glue pressure, will Spray valve On, set time to 4ms then turn back two circles as fixed base inpact glue amount 專屬噴射閥軟體調整 This interface function is empty run Z axis base height: touch auto search Z axis base height: touch auto search and move to next working point to add point, after height conformation, Spray...
  • Page 32 Spray valve basic parameter setting System: From dispense base point, Size of one particle Spray valve dispense is counted in particles dispensed is 1600un The dispense way is side by side and overlaps 1/3 Dispense material example 1600um Dispense z depth doesn’t need to set up low to 0 1600/3=533 is overlapping dispense distance Counts spray frequency base according to work distance N1 is Start point for dispensing, N2 is End point of dispense (Shows in END)
  • Page 33 EM5701N Glue weight 17 18 15 16 Button instructions: 1. Valve parameter interface 2. Valve H1: When currently using H1 valve teaching, can switch H, H2 valve setting 3. Glue weight backup parameter column 4. Use glue weight parameter for H1, H2 valve 5.
  • Page 34: Hardware Instructions

    14. Tank pressure: Tank pressure value, glue output condition write into column, used for recording 15. Standard glue amount selection: Select glue weight parameter, select valve H1, H2, renew parameter function button 16. Perform standard weighing: Construct backup parameters, will input parameter according to 5-16 column value Input weighed value 17.
  • Page 35 Glue weight software operation Place balance under valve first(Hardware 4) and record current container weight Set valve glue output seconds ms Set glue weight Set error value, dispense second dispense amount and set dispense weight error tolerance rate (%) Execute standard weighing: Original coordinate glue output, glue pressure setting(Hardware 1)will impact glue output amount, Set dispense time from step 2 Glue output’s weight –...
  • Page 36 Working glue weight example(Glue weight setting should be after finished) Dispense: Valve setting The dot’s glue weight is 0.01mg Glueing 1. Glueing speed 2. Glueing distance 3. Glueing amount Calculation: Glueing distance ÷ Glueing speed = Glueing amount...
  • Page 37 Screw Valve Cleaning and Maintenance Pay Attention to Dispense head dispense (Please follow the below to guarantee a stable glue amount) Not using it for 2 days in a row:  Method 1:Dispense continuously for 15 seconds everyday  Method 2:Switch glue box into maintenance oil, then press dispense button until the leftover glue are discharged.
  • Page 38 Change the Leak-Proofing ring every 3 months to prevent glue backwash and causing the valve to work improperly Head valve ANV502(ANV512) cleaning and maintenance When cleaning and maintaining, just remove the four “AV601-17” screws, then can clean and maintain the lower half. If the glue is solidified and cannot clean, soak it with Acetone, and clean it after it is softened.
  • Page 39 Spray valve cleaning and maintenance Disassemble tools Consumption and Backup Materials Remove spray valve for Loosen the nuts Remove glue guiding local maintenance (Can loosen nuts first on the component screw machine instead of taking them down) Glue guiding local component Remove firing pin valve Remove washer separation...
  • Page 40 Eight components that will Soak these eight Do not touch Acetone with have contact with the glue components with sealed rings to prevent Acetone. Soaking time destroying it and causing according to each glue leaking glue and clean them with dust-free wiper 10.
  • Page 41 Push it to the end Sealing ring is installed Place the washer Connect the needle head base Install the impact plate Install the needle head with the firing pin 10. Tighten the nuts 11. Tighten the screws 12. Wrap with sealing tape 13.
  • Page 42 Removing spray valve firing pin When to use: In general no need to remove spray valve, just remove and maintain them if there is strange sounds or when glue output isn’t smooth Loosen machine screws Upper half of machine Lower half of the machine Clean the inside with alcohol Sealing ring Be aware of the direction...
  • Page 43 Plastic Needle head specifications When to use: Choose needle size according to glue amount...