  • Page 1 Aussie Eco-Clean Super Indy High Pressure Washer Operating & Maintenance Instructions Read all instructions carefully BEFORE using your Super Indy steam cleaner AUSTRALIAN PUMP INDUSTRIES...
  • Page 2: Risk Assessment

    In line with the National Occupation Health & Safety Commission’s requirements the data below applies to the following Aussie high pressure hot water & steam cleaners:  Sizzler Aussie Pumps provides training  Super Indy series for all Class A machine operators FREE of charge ...
  • Page 3 Risks associated with operating a high pressure cleaner … for use in daily SAFE WORK METHOD STATEMENT Risk Hazard Risk Controls Rating  Warning stickers Entanglement Personal injury of with hose the operator or  hose reel option (tripping, falling) bystanders ...
  • Page 4: Table Of Contents

    Contents Risk Assessment ................... 2 Preparation ..................5 Description of symbols ................ 6 Introduction ..................7 Intended use ..................8 Preliminary operations ............... 8 General warnings for installation & use .......... 10 Use advice on using detergents ............12 Maintenance ..................12 Periods of inactivity ................
  • Page 5: Preparation

    CONGRATULATIONS ON THE PURCHASE OF YOUR AUSSIE SUPER INDY STEAM CLEANER Before attempting to operate your machine please read this Instruction Manual thoroughly following all directions carefully. By doing so you will ensure safe operation of the unit and will enjoy long and trouble free service from your heavy duty water blaster. GUARANTEE This Aussie Eco Clean product is guaranteed against faults in manufacture for one year from purchase. Keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused in any way, or not used for the purpose for which it was intended. Routine maintenance is the owner=s responsibility. Failure to maintain the machine in line with the services outlined on Page 8 will invalidate warranty. Where possible return faulty goods to the place of purchase. No products can be returned to us without our prior permission. The reason for return must be clearly state. N.B. Warranty is not transferrable to third parties in the event of sale of the machine within the warranty period. Please note that any parts used in warranty repairs are guaranteed for a period limited by the original warranty of the parent product.
  • Page 6: Description Of Symbols

    DESCRIPTION OF SYMBOLS ON THE CLEANER DO NOT DIRECT THE JET SWITCHING OF THE PUMP AT PEOPLE, ANIMALS, MOTOR. POWER SOCKETS OR THE MACHINE ITSELF. ATTENTION: LIGHTING THE BURNER. RISK OF BURNS. AT T E N T I O N : R I S K O F ADJUSTING THE WATER ELECTRIC SHOCK. TEMPERATURE. EARTH. FUEL (DIESEL).
  • Page 7: Introduction

    The most important instructions rated and earthed. If an alternative plug needs to be fitted use a qualified electrician. are marked with the symbol: Do not use extensions to feed the H.P. cleaner. The electric safety of this machine may be assured only when it is properly connected to an efficient grounding system in accor- dance with the governing laws for electric safety. (in compliance INTRODUCTION with the provisions of the IEC 60364-1 standard). This manual must be read before installing, setting up and It is necessary to check this essential safety requisite. In case using the cleaner. The manual is an integral part of the product.
  • Page 8: Intended Use

    DATA PLATE: INTENDED USE The data plate bearing the main technical characteristics of your This appliance is intended exclusively for cleaning machines, cleaner is located on the trolley and is always visible. vehicles, buildings and general surfaces suitable for treatment with a high pressure jet of detergent solution between 25 and 250 bar (360 - 3600 PSI). This appliance has been designed for use with the detergents supplied or recommended by the manufacturer. The use of When buying your cleaner, ensure that it has an other detergents or chemicals may influence the safety of the identification plate.
  • Page 9 FILLING THE DETERGENT WATER CIRCUIT CONNEC- TANK TION Use a detergent that suits your Connect the feed hose to cleaning application diluted to the mains (fig. 5A) and to the correct concentration. the hosetail on the cleaner Fill the detergent tank with the (fig. 5B). diluted product (fig. 3). Check that the pressure and quantity of the water supplied by the mains are sufficient for the cleaner to work properly: 2 to 8 BAR (29 to 116 PSI).
  • Page 10: General Warnings For Installation & Use

    GENERAL WARNINGS ABOUT INSTALLATION AND USE The use of any electric appliance requires the respect of The use of the H.P. cleaner must be considered according some basic rules: to the place where the washing is performed (for example: food plants, pharmaceutical plants, etc.) • Do not touch the appliance with wet or damp hands or feet. Pertinent rules and safety conditions must be followed. • Do not use the appliance bare-footed or with unsuitable As for the protection against electric shock, the H.P.cleaner clothing. belongs to CLASS I. • Do not pull the supply cable or the appliance itself in order to disconnect the plug from the electric supply. (For water cleaners rated at less than 3 kW fitted with plug). Do not direct water jets at your own body or others in order to clean clothes or shoes.
  • Page 11 STOPPING THE CLEANER USING THE CLEANER 1) Switch off the burner by turning the pressure regulator CONTROL PANEL to pos. "0" (fig. 7B). A - On/off switch 2) Let the cleaner run with B - Temperature regulator cold water only for at least C - Detergent control tap (if 30 seconds to cool down the available).
  • Page 12: Use Advice On Using Detergents

    REGULATING PRESSURE OPERATING PHASES FOR CORRECT CLEANING WITH AND USING STEAM DETERGENTS (If available) 1) Prepare the solution of detergent at the concentration most suitable for the type of dirt and the surface that is to be This chapter concerns only those models provided with washed. the “pressure regulating” de- 2) Start the cleaner, turn on the detergent tap (if present), switch vice. The pressure regulator, fig.
  • Page 13 OPERATIONS FOR USING CLEANING THE FUEL FIL- ANTIFREEZE (fig. 13) TER AND TANK 1) Turn off the water supply (tap), disconnect the hose Remove and replace the in- and run the cleaner until it is line fuel filter (fig. 16). completely empty. Change it from time to time. 2) Stop the water cleaner with Empty the fuel tank. the ON/OFF switch in the “O” position. 3) Prepare a container with the solution of antifreeze. 4) Immerse the tube in the container with the anti-freeze solution.
  • Page 14: Periods Of Inactivity

    TABLE OF ROUTINE MAINTENANCE TO BE TABLE OF EXTRAORDINARY MAINTENANCE BE PERFORMED BY THE TECHNICAL SERVICE PERFORMED BY THE USER CENTRE Description of operations: Description of operations: Boiler: Check power cable - pipes - high pressure Each use Clean Coil Every 200 hours connectors Descale coil Every 300 hours Clean fuel pump Every 200 hours Ist oil change in H.P. pump After 50 hours Change fuel nozzle Every 200 hours Subsequent changes in H.P. pump Every 500 hours...
  • Page 15: Trouble-Shooting

    TROUBLE-SHOOTING Before carrying out any operations, disconnect the water cleaner from the mains electricity supply via the omni- polar switch or by unplugging the plug from the socket. FAULTS CAUSES REMEDIES When the switch is turned the cleaner Faulty electric connection. Check the mains voltage. does not start. Thermal protection has tripped. Reset (if it trips again, apply to the technical service centre). No jet or leakage from high pressure Check it.
  • Page 16 FAULTS CAUSES REMEDIES Fuel pump dirty. Contact Distributor for service. Fuel solenoid valve not working. Contact Distributor for service. Burner cuts out during operation. Fuel tank is empty (burner will produce Refill the fuel tank. white smoke). Suction filter is dirty. Remove filter and clean using fuel and a brush. Water in fuel. Empty fuel tank, clean and refill with clean fuel.
  • Page 17: Technical Data

    Technical data SUPER INDY SUPER INDY Model • 1012 M - DS DS 2016 T • Power supply 230 / 240 400 / 415 • Absorbed power 3000 7400 • Pressure 1500 2900 1000 • Flow rate • Fuel consumption kg/h Thermal capacity 68,8 68,8 • Water out-put °C 30 ÷ 140 30 ÷ 140 temperature 86 ÷ 284...
  • Page 18: Notes

    Notes: Aussie Eco-Clean Super Indy Operating & Maintenance Manual - 2020...
  • Page 19 Aussie Steam Cleaners | Super Indy & Admiral series Designed for Aussie Conditions Single & three phase options Stainless steel cover & steel   Pressures to 4,000 psi chassis with bumper  Steam to 120 °C Low water cut-out ...
  • Page 20: Routine Check Lists

    IMPORTANT INFORMATION ROUTINE CHECK LIST - IMPORTANT - DAILY: Check pump oil level. If oil is milky contact your Aussie Eco-Clean Distributor for service. Check all high pressure components for leaks: a) gun/lance; b) high pressure hose; c) all fittings. Check power supply cable and plug for damage. Check water inlet filter - clean if necessary. - MONTHLY: Check high pressure nozzle for wear. If pressure has dropped off, replace nozzle. If you machine is used regularly the nozzle may need replacing monthly to maintain performance. Clean detergent suction filter. Change lance nozzle tip. Change oil Check fuel filter - 6 MONTHLY/250 HOURS: - Contact your Aussie Eco-Clean Distributor for recommended service.