6 Maintenance and Service 6.1 Replacing the Line Fuse 6.2 Replacing the Internal Fuses 6.3 Troubleshooting 6.4 The TXP5000 Series Administrator 6.4.1 Connect the TXP5016 via RS232 6.4.2 Connect the TXP5016 via LAN 6.4.3 Device ID and Information 6.4.4 Network Configuration 6.4.5...
Prior to applying power to the TXP5016, make sure that the protective conductor of the 3 conductor mains power cord is correctly connected to the protective earth ground...
Page 6
TXP5016 Thorlabs GmbH is not responsible for any radio television interference caused by modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Thorlabs GmbH. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
· Windows 8.x (32-bit, 64-bit) For operation of the TXP5016, also an NI-VISA (version 5.4.1 or higher) is required. This NI- VISA engines comes with the Thorlabs GmbH TXP5016 installation software package, but can be downloaded also from National Instruments' website www.ni.com.
Inspect the shipping container for damage. If the shipping container seems to be damaged, keep it until you have inspected the contents and you have inspected the TXP5016 mechanically and electrically. Verify that you have received the following items within the package: TXP5016 1.
TXP5016 3 Operating Elements TXP5016 Front panel LED "READY". Blinking: TXP5016 is booting Constant: TXP5016 ready for operation LED "Power ON" Mains switch LED "Ethernet Connected" LED "Data Transfer" RJ45 Ethernet connector RS232C connector, 9 pin DSUB male, for mainframe configuration...
In this position the TXP module is disabled! Correct position · Connect the power cord to your TXP5016 and switch it on. The green LED "Power ON" must light up. 4.1 Network Configuration The TXP5016 has an internal web server that is accessible via the RJ45 jack on the front panel.
Page 14
The TXP5016 serial interface works with a transfer rate from 9600 to 115200 bps, 8N1 protocol. Make sure, the TXP5016 is switched on and the serial connection is made. Open from the Start button the TXP Administrator: Click Connect in the menu bar.
Page 16
TXP5016 Verification of the network configuration Connect the TXP5016 to you LAN (normal RJ45 patch cable) or to the RJ45 connector of you PC (cross-over cable). Now you can verify the LAN connectivity. Just type in the assigned to the TXP5016 IP address in your browser. If the configuration was done properly, the browser connects to the TXP5016 internal web server: The TXP5016 is ready for operation now.
5.2 Global Interlock The TXP5016 comes with a "global" interlock that provides a safety function to all installed TXP modules simultaneously. This safety function is module-dependent: · TXP laser sources: opening the interlock, the laser emission is switched off.
Page 18
Interlock circuit This is the standard connection of a closed interlock, as it provided with the interlock plug that comes with the TXP5016. The Constant Current output is supplied to the opto-coupler inputs ALARM+ (pin 9) and ALARM- (pin 4).
Page 19
5 Operating Instruction Cascading the interlock of multiple TXP5016 mainframes Up to five TXP5016 mainframes can be cascaded in order to use a common interlock. The interlock opens and the safety function of all cascaded mainframes is triggered as soon as the current is interrupted. In other words, an active-open switch should be placed then between contacts 5 and 9 of the first mainframe.
TXP5016 6 Maintenance and Service Protect the TXP5016 from adverse weather conditions. The TXP5016 is not water resistant. Attention To avoid damage to the instrument, do not expose it to spray, liquids or solvents! The unit does not need a regular maintenance by the user. It does not contain any modules and/or components that could be repaired by the user himself.
Attention To avoid fire hazard only the appropriate fuses must be used! · Switch off the TXP5016 and remove the power cable from the mains jack. Look at the back of the unit. · Open the cover of the fuse holder at the rear using a small screwdriver.
Configuration. Ø Do you use the correct network cable? o Use the cross-over cable for direct connection of the TXP5016 to the network port of your PC. o Use the standard patch cable for connection of the TXP5016 to the LAN.
6 Maintenance and Service 6.4 The TXP5000 Series Administrator The TXP5000 Series Administrator that comes with installation package, is a tool to configure the connected TXP5016. The connection can be made via the RS232 interface or via the local area network: Pros Cons Serial Connection ·...
Page 24
This menu offers the same functions as the buttons on the main window. 3. Menu Help Contents F1 opens the TXP Administrator online help. Visit the Thorlabs Web Site opens www.thorlabs.com your default browser. An internet connection is required. About...
6.4.1 Connect the TXP5016 via RS232 Switch on the TXP5016. Connect the RS232C serial port (male DB9 connector on the front panel) of your TXP5016 to a serial port of your PC using a null-modem cable. If your PC has no serial port, you can use any commercially available USB-to-Serial Converter.
6 Maintenance and Service 6.4.2 Connect the TXP5016 via LAN Important Note The TXP Administrator software can connect to the TXP5016 via LAN only if the local Windows Firewall of the control PC is switched off! Switch on the TXP5016.
6.4.3 Device ID and Information This topic allows to change the device ID and to view device information. Click the button: Tab Identification Enter an appropriate name to easier identify your TXP5016 in the network. Then press the Transfer button. Tab Information The TXP5016 system information can be viewed by scrolling the window.
6 Maintenance and Service 6.4.4 Network Configuration The TXP5016 has an internal web server that is accessible via the RJ45 jack on the front panel. The IP address of the TXP5016 is factory set to IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0...
Page 30
TXP5016 Verification of the network configuration Connect the TXP5016 to you LAN (normal RJ45 patch cable) or to the RJ45 connector of you PC (cross-over cable). Now you can verify the LAN connectivity. Just type in the assigned to the TXP5016 IP address in your browser. If the configuration was done properly, the browser connects to the TXP5016 internal web server: The TXP5016 is ready for operation now.
6 Maintenance and Service 6.4.5 Adjust Time and Date This topic allows to sychronize date and time information stored in the TXP5016 with the settings of the control PC. Click the button Click Synchronize. Click OK to close the topic.
TXP5016 6.4.6 Software Updates This topic is used for updating the internal TXP5016 software. Please visit https://www.thorlabs.com/software_pages/ViewSoftwarePage.cfm?Code=TXP5000 and select the tab Firmware for downloading: Click the Download button and save the tgz archive to your download folder: Note A firmware update does not affect the settings for device IP address and the assigned password.
Page 34
Confirm with OK to proceed. Make sure that the software transfer progress is not interrupted by a power-down or by disconnecting the serial cable. After the process was carried out successfully, the TXP5016 automatically restarts. Click Exit to close the topic. The TXP Administrator is disconnected from the device.
6 Maintenance and Service 6.4.7 Change Device Password The TXP5016 has by factory default no password. In order to access the TXP5016 via network, you need to assign a password. Click the button Enter a (new) password and re-enter it to the second line again for verification. The click Ok.
For warranty repairs or service the unit must be sent back to Thorlabs GmbH. The customer will carry the shipping costs to Thorlabs GmbH, in case of warranty repairs Thorlabs GmbH will carry the shipping costs back to the customer.
Waste treatment on your own responsibility If you do not return an “end of life” unit to Thorlabs GmbH, you must hand it to a company specialized in waste recovery. Do not dispose of the unit in a litter bin or at a public waste disposal site.
Email: europe@thorlabs.com Email: scandinavia@thorlabs.com France Brazil Thorlabs SAS Thorlabs Vendas de Fotônicos Ltda. 109, rue des Côtes Rua Riachuelo, 171 78600 Maisons-Laffitte São Carlos, SP 13560-110 France Brazil Tel: +33-970 444 844 Tel: +55-16-3413 7062 Fax: +33-811 38 17 48 Fax: +55-16-3413 7064 www.thorlabs.com...
Need help?
Do you have a question about the TXP5016 and is the answer not in the manual?
Questions and answers