  • Page 1 Thorlabs Instrumentation TXP5016 Operation Manual 2017...
  • Page 2 Version: 3.1.5 Date: 31-Jan-2017 Item No.: M0009-510-102 Copyright © 2017 Thorlabs GmbH...
  • Page 3: Table Of Contents

    6 Maintenance and Service 6.1 Replacing the Line Fuse 6.2 Replacing the Internal Fuses 6.3 Troubleshooting 6.4 The TXP5000 Series Administrator 6.4.1 Connect the TXP5016 via RS232 6.4.2 Connect the TXP5016 via LAN 6.4.3 Device ID and Information 6.4.4 Network Configuration 6.4.5...
  • Page 4: Foreword

    Paragraphs preceeded by this symbol explain hazards that could damage the instrument and the connected equipment or may cause loss of data. Note This manual also contains "NOTES" and "HINTS" written in this form. Please read these advices carefully! © 2017 Thorlabs GmbH...
  • Page 5: General Information

    Prior to applying power to the TXP5016, make sure that the protective conductor of the 3 conductor mains power cord is correctly connected to the protective earth ground...
  • Page 6 TXP5016 Thorlabs GmbH is not responsible for any radio television interference caused by modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Thorlabs GmbH. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
  • Page 7: Ordering Codes And Accessories

    · Windows 8.x (32-bit, 64-bit) For operation of the TXP5016, also an NI-VISA (version 5.4.1 or higher) is required. This NI- VISA engines comes with the Thorlabs GmbH TXP5016 installation software package, but can be downloaded also from National Instruments' website www.ni.com.
  • Page 8: Getting Started

    Inspect the shipping container for damage. If the shipping container seems to be damaged, keep it until you have inspected the contents and you have inspected the TXP5016 mechanically and electrically. Verify that you have received the following items within the package: TXP5016 1.
  • Page 9 2 Getting Started Allow the installation. Then follow the the screenshots below: © 2017 Thorlabs GmbH...
  • Page 10 TXP5016 © 2017 Thorlabs GmbH...
  • Page 11 This Windows Security message appears twice. You may be requested to restart your computer upon finishing software installation. Note If you are requested to restart your computer, please do so. Otherwise, the TXP software won't operate properly. © 2017 Thorlabs GmbH...
  • Page 12: Operating Elements Txp5016

    TXP5016 3 Operating Elements TXP5016 Front panel LED "READY". Blinking: TXP5016 is booting Constant: TXP5016 ready for operation LED "Power ON" Mains switch LED "Ethernet Connected" LED "Data Transfer" RJ45 Ethernet connector RS232C connector, 9 pin DSUB male, for mainframe configuration...
  • Page 13: First Steps

    In this position the TXP module is disabled! Correct position · Connect the power cord to your TXP5016 and switch it on. The green LED "Power ON" must light up. 4.1 Network Configuration The TXP5016 has an internal web server that is accessible via the RJ45 jack on the front panel.
  • Page 14 The TXP5016 serial interface works with a transfer rate from 9600 to 115200 bps, 8N1 protocol. Make sure, the TXP5016 is switched on and the serial connection is made. Open from the Start button the TXP Administrator: Click Connect in the menu bar.
  • Page 15 Now enter the required IP Address and Subnet Mask. For gateway operation, check the Use Gateway box and enter the gateway IP address in the bottom line. Then click Transfer. The TXP5016 reboots to finalize the configuration. © 2017 Thorlabs GmbH...
  • Page 16 TXP5016 Verification of the network configuration Connect the TXP5016 to you LAN (normal RJ45 patch cable) or to the RJ45 connector of you PC (cross-over cable). Now you can verify the LAN connectivity. Just type in the assigned to the TXP5016 IP address in your browser. If the configuration was done properly, the browser connects to the TXP5016 internal web server: The TXP5016 is ready for operation now.
  • Page 17: Operating Instruction

    5.2 Global Interlock The TXP5016 comes with a "global" interlock that provides a safety function to all installed TXP modules simultaneously. This safety function is module-dependent: · TXP laser sources: opening the interlock, the laser emission is switched off.
  • Page 18 Interlock circuit This is the standard connection of a closed interlock, as it provided with the interlock plug that comes with the TXP5016. The Constant Current output is supplied to the opto-coupler inputs ALARM+ (pin 9) and ALARM- (pin 4).
  • Page 19 5 Operating Instruction Cascading the interlock of multiple TXP5016 mainframes Up to five TXP5016 mainframes can be cascaded in order to use a common interlock. The interlock opens and the safety function of all cascaded mainframes is triggered as soon as the current is interrupted. In other words, an active-open switch should be placed then between contacts 5 and 9 of the first mainframe.
  • Page 20: Maintenance And Service

    TXP5016 6 Maintenance and Service Protect the TXP5016 from adverse weather conditions. The TXP5016 is not water resistant. Attention To avoid damage to the instrument, do not expose it to spray, liquids or solvents! The unit does not need a regular maintenance by the user. It does not contain any modules and/or components that could be repaired by the user himself.
  • Page 21: Replacing The Line Fuse

    Attention To avoid fire hazard only the appropriate fuses must be used! · Switch off the TXP5016 and remove the power cable from the mains jack. Look at the back of the unit. · Open the cover of the fuse holder at the rear using a small screwdriver.
  • Page 22: Troubleshooting

    Configuration. Ø Do you use the correct network cable? o Use the cross-over cable for direct connection of the TXP5016 to the network port of your PC. o Use the standard patch cable for connection of the TXP5016 to the LAN.
  • Page 23: The Txp5000 Series Administrator

    6 Maintenance and Service 6.4 The TXP5000 Series Administrator The TXP5000 Series Administrator that comes with installation package, is a tool to configure the connected TXP5016. The connection can be made via the RS232 interface or via the local area network: Pros Cons Serial Connection ·...
  • Page 24 This menu offers the same functions as the buttons on the main window. 3. Menu Help Contents F1 opens the TXP Administrator online help. Visit the Thorlabs Web Site opens www.thorlabs.com your default browser. An internet connection is required. About...
  • Page 25: Connect The Txp5016 Via Rs232

    6.4.1 Connect the TXP5016 via RS232 Switch on the TXP5016. Connect the RS232C serial port (male DB9 connector on the front panel) of your TXP5016 to a serial port of your PC using a null-modem cable. If your PC has no serial port, you can use any commercially available USB-to-Serial Converter.
  • Page 26 Select the connection type to Serial Line (RS232) and the Serial Port to COMx, as stated in the device manager. Then click Connect. The TXP Administrator connects to the device and reads out the device information. When done, the header shows © 2017 Thorlabs GmbH...
  • Page 27: Connect The Txp5016 Via Lan

    6 Maintenance and Service 6.4.2 Connect the TXP5016 via LAN Important Note The TXP Administrator software can connect to the TXP5016 via LAN only if the local Windows Firewall of the control PC is switched off! Switch on the TXP5016.
  • Page 28: Device Id And Information

    6.4.3 Device ID and Information This topic allows to change the device ID and to view device information. Click the button: Tab Identification Enter an appropriate name to easier identify your TXP5016 in the network. Then press the Transfer button. Tab Information The TXP5016 system information can be viewed by scrolling the window.
  • Page 29: Network Configuration

    6 Maintenance and Service 6.4.4 Network Configuration The TXP5016 has an internal web server that is accessible via the RJ45 jack on the front panel. The IP address of the TXP5016 is factory set to IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0...
  • Page 30 TXP5016 Verification of the network configuration Connect the TXP5016 to you LAN (normal RJ45 patch cable) or to the RJ45 connector of you PC (cross-over cable). Now you can verify the LAN connectivity. Just type in the assigned to the TXP5016 IP address in your browser. If the configuration was done properly, the browser connects to the TXP5016 internal web server: The TXP5016 is ready for operation now.
  • Page 31: Adjust Time And Date

    6 Maintenance and Service 6.4.5 Adjust Time and Date This topic allows to sychronize date and time information stored in the TXP5016 with the settings of the control PC. Click the button Click Synchronize. Click OK to close the topic.
  • Page 32: Software Updates

    TXP5016 6.4.6 Software Updates This topic is used for updating the internal TXP5016 software. Please visit https://www.thorlabs.com/software_pages/ViewSoftwarePage.cfm?Code=TXP5000 and select the tab Firmware for downloading: Click the Download button and save the tgz archive to your download folder: Note A firmware update does not affect the settings for device IP address and the assigned password.
  • Page 33 6 Maintenance and Service Click Browse and find your download location: Select the tgz file. Click Start. © 2017 Thorlabs GmbH...
  • Page 34 Confirm with OK to proceed. Make sure that the software transfer progress is not interrupted by a power-down or by disconnecting the serial cable. After the process was carried out successfully, the TXP5016 automatically restarts. Click Exit to close the topic. The TXP Administrator is disconnected from the device.
  • Page 35: Change Device Password

    6 Maintenance and Service 6.4.7 Change Device Password The TXP5016 has by factory default no password. In order to access the TXP5016 via network, you need to assign a password. Click the button Enter a (new) password and re-enter it to the second line again for verification. The click Ok.
  • Page 36: Appendix

    Pollution Degree (indoor use only) Operation Altitude < 2000 m Warm-up Time (typ.) 10 min Weight (empty) 7 kg ) non-condensing All technical data are valid at 23 ± 5°C and 45 ± 15% rel. humidity (non condensing) © 2017 Thorlabs GmbH...
  • Page 37: Certifications And Compliances

    Compliance demonstrated with various TX Series light source and electrical modules installed Emissions, which exceed the levels required by these standards, may occur when this equipment is connected to a test object. Minimum Immunity Test Requirement Replaces Low Voltage Directive 73/23/EEC, amended by93/68/EEC © 2017 Thorlabs GmbH...
  • Page 38: Warranty

    For warranty repairs or service the unit must be sent back to Thorlabs GmbH. The customer will carry the shipping costs to Thorlabs GmbH, in case of warranty repairs Thorlabs GmbH will carry the shipping costs back to the customer.
  • Page 39: Copyright And Exclusion Of Reliability

    Thorlabs GmbH dealer or system installer. All rights reserved. This document may not be reproduced, transmitted or translated to another language, either as a whole or in parts, without the prior written permission of Thorlabs GmbH. Copyright © Thorlabs GmbH 2017. All rights reserved.
  • Page 40: Thorlabs 'End Of Life' Policy

    Waste treatment on your own responsibility If you do not return an “end of life” unit to Thorlabs GmbH, you must hand it to a company specialized in waste recovery. Do not dispose of the unit in a litter bin or at a public waste disposal site.
  • Page 41: Thorlabs Worldwide Contacts

    Email: europe@thorlabs.com Email: scandinavia@thorlabs.com France Brazil Thorlabs SAS Thorlabs Vendas de Fotônicos Ltda. 109, rue des Côtes Rua Riachuelo, 171 78600 Maisons-Laffitte São Carlos, SP 13560-110 France Brazil Tel: +33-970 444 844 Tel: +55-16-3413 7062 Fax: +33-811 38 17 48 Fax: +55-16-3413 7064 www.thorlabs.com...
  • Page 44 www.thorlabs.com...