  • Page 1 pure·2 electronica in-wall thermostatic tubfiller with handshower & hose Installation Guide TEP431.01 2018-09 1 866 907 0122 blubathworks.com ®...
  • Page 2: Installation Requirements

    Attention – Before Installation Inspect this product to ensure you have all parts as shown that are required for proper installation. The valve cartridge has been factory tested and adjusted – DO NOT TAKE THE CARTRIDGE APART. Taking the cartridge apart will void the warranty. Ensure that both hot and cold water feeds are properly connected to the marked lav connecting.
  • Page 3 Step 1 - Bathtub spout Screw the rod (1) on the pipe (2). Place the foam gasket (3) on the back part of the plate (4). Place the plate (4) on the finished wall. Step 2 - Bathtub spout Place the O-ring (5) on the spout (6). Place the spout (6) on the rod and fix it with the grub screw (7).
  • Page 4 Step 3 - Handshower Screw the rod (1) on the pipe (2). Slide the holder on the rod & fix with grub screw (7). Attach the hose to the handshower. Step 4 - Two outlet shower/tub control Please refer to steps 1-9 below 2018-09 1 866 907 0122 blubathworks.com...
  • Page 5 Step 1 - Assembly of the Control Fixing Bracket to the In-wall Plate Finish the wall by tiling or using drywall. Using the trim plate, the control fixing brackets must be positioned using the supplied in-wall rough-in plate with their centres 70mm apart. 40mm diameter holes are required Conduits should be used in the walls where necessary to protect the cables and allow maintenance.
  • Page 6 Step 4 Cut down the bracket collars as marked. Step 5 adaptor ring a: Position the adaptor rings inside the wall and fix through the adaptor ring holes into the bracket collar using 15mm screws supplied (manually.) Note: Do no use an electric drill. 2018-09 1 866 907 0122 blubathworks.com...
  • Page 7 Step 6 Feed the control data cables through the brackets. Note: For ease of installation, the socket can be taped to the wire. Step 7 Position the controls into the brackets and turn clockwise to lock in position. 2018-09 1 866 907 0122 blubathworks.com ®...
  • Page 8 Step 8 Push fit the ‘front’ control wheels onto the controls. Step 9 - Preset temperature & flow selection temperature cleaning volume regulation push & turn push & hold green tap 1x - cold tap 2x - warm tap 3x - hot turn push 2018-09...
  • Page 9 TEP431.01 2018-09 1 866 907 0122 blubathworks.com ®...
  • Page 10 DUO·1 two outlet electronica thermostatic bathtub control mixer Installation Guide TEE030 2013-12 1 866 907 0122 blubathworks.com ®...
  • Page 11 Step 1 - connecting the control mixer for shower & bathtub installation Remove the control mixer cover. Important: The control mixer must be installed in a dry area that is accessible for future maintenance Step 2 - components of two outlet thermostatic mixer Connector block Fixing holes Power supply...
  • Page 12 Step 3 Step 4 If required, use the supplie template to mark the Fix the control box in position using the position of the control mixer fixing holes in the screw kit supplied. selected location. Step 6 Step 5 Fully insert the inlet connectors into the inlet valves (one long and one short connector).
  • Page 13 Step 7 Step 8 not supplied Cold cold Re-insert the inlet connectors retaining bolt. Important: Flush through the pipework before connection. Filter screen for inlet is highly recommended. Attach the NPT adaptors to the hot & cold water supply connections. Step 10 Step 9 Fully insert the outlet connectors into the outlet...
  • Page 14 Step 11 Step 12 Attach the supplied NPT adaptor pipework to Re-insert the outlet connectors retaining bolt. the outlet connectors. Make a note of which pipe goes to which outlet. Note: Make sure that the pipework is perpendicular to the control box so that there is no strain on the fittings, use pipe clips as required.
  • Page 15 Step 22 - Connect flow/outlet control data cable Step 22 - Connect flow/outlet control data cable Step 14 - connect flow/outlet control data cable Connect the data cable from the flow volume/ divertor control to the “dual wheel” connection in the “AUX”...
  • Page 16 Step 16 Refit the control box cover. DIGITAL WATER CONTROL AT YOUR FINGERTIPS Step 25 Step 17 Connect an all-pole mains switch in the electrical installation in accordance with the current wiring regulations. Note: • the electrical installation and testing must be carried out by a qualified electrician •...