Download Print this page

Superior Fireplaces VRE4032 Series Manual page 2

Vent-free universal tall opening firebox

Advertisement

Cat. No.
Model
F0485
VRE4032RS
F0491
VRE4032WS
F0486
VRE4032RH
F0492
VRE4032WH White Herringbone 138 lb
Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material
Firebox
Wire-mesh
Screen
Nails or Wood
Screws
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Printed in U.S.A. © 2016 Innovative Hearth Products
P/N 900667-02 REV. NC 05/2016
VRE4032 SERIES
Refractory
Weight
Red Stacked
138 lb
White Stacked
138 lb
Red Herringbone
138 lb
Mantel Shelf
Note: Any portion of the
Inch (millimeter)
mantel shelf must NOT
extend beyond this profile.
12 (305)
6-3/4 (172)
1-1/2 (38)
Noncombustible
16
Material May
(407)
Project Off this
Surface above
12
the Firebox Hood
(305)
Note: All vertical
measurements are
Supplied
from top of fireplace
Firebox Hood
hood opening to
Must Be Used
bottom of mantel shelf.
at All Times
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Nailing
Flanges
Indoor Firebox
PFS
Cu. Ft.
14
C
14
Report No. F09-130
14
14
Minimum Wall and Ceiling Clearances (see fi gure below)
A. Clearances from the side of the fi replace cabinet to any combustible
material and wall should follow diagram shown here.
Example: The face of a mantel, bookshelf, etc. is made of combustible
material and protrudes 3-1/2" from the wall. This combustible mate-
rial must be 4" from the side of the fi replace cabinet.
B. Clearances from the top of the fi rebox opening to the ceiling should
not be less than 42".
C. When the fi rebox is installed directly on carpeting, vinyl tile or other
combustible material, other than wood fl ooring, the fi rebox should be
20
(508)
installed on a metal or wood panel extending the full width and depth
of the enclosure.
D. Clearances from the bottom of fi rebox to the fl oor is 0".
Nails or
Wood
Screws
These appliances comply with National
Safety Standards and are listed by PFS Cor-
®
poration to ANSI Z21.91 Ventless Firebox
US
Enclosures for Gas-Fired Unvented Decora-
tive Room Heaters and is approved for use
with appliances listed to ANSI Z21.11.2
decorative type unvented room heaters.
Inch (millimeter)
Example
4
1/2
1
2
6
8
10
(13)
(26)
(51)
(102)
(153)
(204)
(254)
(305)
Nailing
Flanges
Indoor/Outdoor Firebox
Specifi cations and clearances are subject to change without notice.
Refer to Installation Manual before installation of these appliances for
updated dimensions and instructions.
12-1/4 (312)
10-1/2 (267)
8-3/4 (223)
7 (178)
5-1/4 (134)
3-1/2 (89)
1-3/4 (45)
7/8 (23)
1/2 (13)
12
14
16
(356)
(407)
Page 2 of 2

Advertisement

loading

This manual is also suitable for:

Vre4032rsVre4032wsVre4032rhVre4032whF0485F0486 ... Show all