Summary of Contents for MICRO-EPSILON Outdoor protective housing

  • Page 1 Operating Instructions Outdoor Protective Housing for thermoIMAGER...
  • Page 2 Outdoor Protective Housing for thermoIMAGER TIM cameras MICRO-EPSILON MESSTECHNIK GmbH & Co. KG Koenigbacher Str. 15 94496 Ortenburg / Germany Tel. +49 (0) 8542 / 168-0 Fax +49 (0) 8542 / 168-90 e-mail info@micro-epsilon.com www.micro-epsilon.com...
  • Page 3: Table Of Contents

    Table of Contents Table of Contents Table of Contents ............................. 3 General Information ..........................5 Description ............................5 Notes on CE Marking ........................6 Unpacking, Included in Delivery ....................... 6 Technical Data ............................7 General Specifications ........................7 Dimensions ............................9 Electrical Connections ........................
  • Page 4 Table of Contents Mounting of the TIM Camera......................17 Mounting of the thermometer TIM 8 and the thermoIMAGER TIM 40 Camera ......21 Mounting of thermoMETER CSL / thermoMETER CTL ..............22 Optional Accessoires ..........................24 Industrial Process Interface (PIF) ....................24 Wall Mount .............................
  • Page 5: General Information

    CTL and the USB server for applications with additional influences of different kinds. It protects the devices among things like dirt, dust and moisture. The outdoor protective housing can be used for any TIM camera (lenses up to 90 ° FOV). The integrated heating and the blower result in an extended operating temperature.
  • Page 6: Notes On Ce Marking

    General Information 1.2 Notes on CE Marking The following apply to the Outdoor Protective Housing:  EU Directive 2014/30/EU  EU Directive 2011/65/EU, “RoHS“ category 11 Products which carry the CE mark satisfy the requirements of the EU directives cited and the relevant ap- plicable harmonized European standards (EN).
  • Page 7: Technical Data

    Technical Data 2 Technical Data 2.1 General Specifications -40 °C … +50 °C Temperature range Heating PTC heater (automatically starting at T < 15 °C) / fan for homogeneous temperature distribution Power supply 24 V DC Power 70 W Protective window Germanium (Ge), zinc sulfide (ZnS), Borofloat or foil Environmental rating IP66...
  • Page 8 Technical Data 1) The fan is switched parallel to the heater. When the heater starts, the fan will also run. The heating is switched on when the temperature falls below 15 °C (closing temperature) and switched off (opening temperature) at 25 °C (±5°C). 2) There is no protection window for the thermoMETER TIM 8 and the thermoIMAGER TIM 40.
  • Page 9: Dimensions

    Technical Data 2.2 Dimensions Figure 1 Dimensions with wall mount, dimensions in mm, not to scale...
  • Page 10 Technical Data Figure 2: Dimensions for wall mount, dimensions in mm, not to scale...
  • Page 11: Electrical Connections

    Technical Data 2.3 Electrical Connections Power supply Industrial PIF and USB server Figure 3: Connection circuit board...
  • Page 12: Air Purge Collar

    Technical Data 2.4 Air Purge Collar The lens must be kept clean at all times from dust, smoke, fumes and other contaminants in order to avoid reading errors. These effects can be reduced by using an air purge collar. Make sure to use oil-free, technically clean air only.
  • Page 13: Installation

    Installation 3 Installation 3.1 Electrical Installation Loosen the two screws and open the outdoor protective housing, as shown in Figure 4. Figure 4: Opening the housing...
  • Page 14 Installation Inside the protective housing is the electronic circuit board, where all loads are connected (see Figure 3). The heating element and the fan are already integrated and connected. To supply the outdoor protective housing with voltage, you must connect a 24 V line. This is connected to the marked side of the board. Observe the correct polarity and ensure that no voltage is present.
  • Page 15: Mounting Of The Usb Server

    Installation 3.2 Mounting of the USB Server Insert the USB server at a slanted angle to the designated disk (Figure 6). If necessary, remove the clip from the USB server (Figure 7) and turn the USB server (Figure 6) until the clip is locked into the bracket (Figure 8).
  • Page 16 Installation The USB server is now ready mounted (Figure 9): Figure 9: USB server ready mounted...
  • Page 17: Mounting Of The Tim Camera

    Installation 3.3 Mounting of the TIM Camera Step 1: Loosen the knurled screw from the mounting plate (Figure 10). Figure 10: Loosen the knurled screw from mounting plate...
  • Page 18 Installation Step 2: Carefully remove the mounting plate (Figure 11). Figure 11: Remove the mounting plate...
  • Page 19 Installation Step 3: Mounting the TIM cameras Figure 12: TIM 4xx/ 640/ 1M/ 05M Figure 13: TIM 160 attachment Figure 14: TIM 2xx attachment attachment Mount the TIM QVGA/ TIM QVGA-HD/ TIM 640/ TIM M-1/ TIM M-05 to the mounting plate using the supplied 1/4 x 3/8 UNC inch screw and a washer DIN125A-6,4 A2 (Figure 12).
  • Page 20 After the camera is fully assembled, the mounting plate can be attached back to the outdoor protective housing with the provided screw. Figure 15: Fully assembled TIM camera on mounting Figure 16: Fully assembled TIM camera in outdoor protective housing...
  • Page 21: Mounting Of The Thermometer Tim 8 And The Thermoimager Tim 40 Camera

    Figure 17 thermoMETER TIM 8 and the Figure 18 Fully assembled thermoMETER TIM 8 and the thermoIMAGER thermoIMAGER TIM 40 camera mounted in adapter plate TIM 40 camera in outdoor protective housing...
  • Page 22: Mounting Of Thermometer Csl / Thermometer Ctl

    Installation 3.5 Mounting of thermoMETER CSL / thermoMETER CTL Follow steps 1 and 2 as described in chapter Fehler! Verweisquelle konnte nicht gefunden werden.. Mounting of thermoMETER CSL / thermoMETER CTL Attach the device with the corresponding bracket. Mount the CSL or CTL to the mounting plate using the supplied 1/4 x 3/8 UNC inch screw and a washer DIN125A-6,4 A2 (Figure 19).
  • Page 23 Installation Figure 21: thermometer CSL or CTL in outdoor Figure 20: Mounted thermometer CSL or CTL on the mounting plate protective housing...
  • Page 24: Optional Accessoires

    In addition to the installation of the TIM camera and the USB server, the industrial PIF (without housing) can be integrated into the outdoor protective housing as shown in Figure 22. The industrial PIF without housing can be purchased under the order number TM-CJAPIF-TIM.
  • Page 25: Wall Mount

    Optional Accessoires 4.2 Wall Mount The outdoor protective housing can be attached to a wall using a wall mount. This is available as an option under the part number TM-OPHWM-TIM. Abbildung 23: Outdoor protective housing with wall mount The wall bracket is mandatory for a mounting of the protective housing!
  • Page 26: Replacement Of Protective Foil

    Replacement of Protective Foil 5 Replacement of Protective Foil If necessary, the protective foil of the outdoor protective housing can be replaced (only for Part-Number: TM-OPHF-TIM). To change the protective foil a screwdriver and a scalpel is needed. 5.1 Disassembling Air Purge Collar Step 1: Unscrew the 9 screws from the adapter plate using a screwdriver and remove them together with the washers.
  • Page 27 Replacement of Protective Foil Step 2: Gently remove the air purge collar with O-ring 1. Figure 26: Remove air purge collar...
  • Page 28: Removing And Inserting The Protective Foil

    Replacement of Protective Foil 5.2 Removing and Inserting the Protective Foil Step 1: Remove the old protective foil by removing the tension ring attachment and the tension ring. Figure 27: Remove old protective foil...
  • Page 29 Replacement of Protective Foil Step 2: Replace the old protective foil with the new protective foil. Step 3: Insert the O-ring 2 in the air purge collar. Step 4: Place the protective foil on the center of the air purge collar and press it with the aid of the tension ring and the tension ring attachment until the tension ring attachment is level with the air purge collar.
  • Page 30: Cut The Protective Foil

    Replacement of Protective Foil 5.3 Cut the Protective Foil Step 1: Take a scalpel and cut along the inside of the nut. Figure 29: Cut the protective foil with the scalpel Figure 30: Cut the protective foil along the nut inner surface...
  • Page 31 Replacement of Protective Foil Step 2: Insert the O-ring 1 into the nut of the air purge collar and repeat the steps in chapter 5.1 reverse. Make sure that the air purge collar is pressed against the adapter plate, when you tighten the screws again! Figure 32: Insert O-ring 1 in air purge collar Figure 31: Air purge collar...
  • Page 32: Liability For Material Defects

    The liability for material defects is 12 months from delivery. Within this period, defective parts, except for wearing parts, will be repaired or replaced free of charge, if the device is returned to MICRO-EPSILON with shipping costs prepaid. Any damage that is caused by improper handling, the use of force or by repairs or modifications by third parties is not covered by the liability for material defects.
  • Page 34 MICRO-EPSILON MESSTECHNIK GmbH & Co. KG X9751374-A032070HDR Koenigbacher Str. 15 · 94496 Ortenburg / Germany Tel. +49 (0) 8542 / 168-0 · Fax +49 (0) 8542 / 168-90 MICRO-EPSILON MESSTECHNIK info@micro-epsilon.com · www.micro-epsilon.com *X9751374-A03* Your local contact: www.micro-epsilon.com/contact/worldwide/...

Table of Contents