Scientific SM5074 User Manual

3 mhz function generator/ counter

Advertisement

Quick Links

3 MHz Function Generator/
Counter
SM5074/ SM5075
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SM5074 and is the answer not in the manual?

Questions and answers

Summary of Contents for Scientific SM5074

  • Page 1 3 MHz Function Generator/ Counter SM5074/ SM5075 User Manual...
  • Page 2: List Of Service Centers

    Information in this manual supercede all corresponding previous released material. Scientific continues to improve products and reserves rights to amend part or all of the specifications, procedures, equipment at any time without notice. Rev 2.2 / 1212 Scientific Mes-Technik Pvt.
  • Page 3: Table Of Contents

    Use as Sweep Function Generator........21 DC Offset................22 Trigger Output..............22 Use as External Frequency Counter......... 22 Maintenance ………………………………..….…....23 Power Line Fuse Replacement …………….....23 Dispatch Procedure For Service.......... 24 Warranty Conditions..……………..…...…....25 List of Service Centers..……………........2 User Manual SM5074/ SM5075...
  • Page 4: Introduction

    3 MHz Function Generator Counter SM5074 / SM5075 Frequency Range 0.3 Hz to 3 MHz ¦ Operating Modes : Function Generator, Frequency Counter, Amplitude Display ¦ Modulation : AM Standard & Balance, FM Int. & Ext., PWM, PAM ¦ Function Generator : Sine,Square,Triangle, Ramp, Pulse, Invert Ramp, Invert Pulse, TTL, DC ¦...
  • Page 5: Technical Specifications

    Polarity ve or - ve selectable Duty Cycle Adjustable 10% to 90% up to 300 kHz & 20% to 80% 300 kHz to 3MHz TTL/Trigger Output Square Wave synchronous to signal output, TTL 4 Vpp > User Manual SM5074/ SM5075...
  • Page 6 Sweep Range : approx. 1 : 100 approx. Input Voltage 30 V max. ± Pulse Width Modulation Input 30 V max (Mod connector on rear panel) ± Modulation Index : 20 to 80 % or better User Manual SM5074/ SM5075...
  • Page 7 ± Power consumption 30 VA approx. Operating Conditions 0 to 50 C , RH 95 % Dimensions W : 205, H : 95, D : 292 (mm) Weight 2.4 kg (approx.) ( Subject to Change ) User Manual SM5074/ SM5075...
  • Page 8: Front Panel Diagram Sm 5074

    Front Panel Controls 5074 z AM FM Function Generator Counter 5074 User Manual SM5074/ SM5075...
  • Page 9: Front Panel Diagram Sm 5075

    Front Panel Controls z AM FM Function Generator Counter 5075 User Manual SM5074/ SM5075...
  • Page 10 Used in frequency counter mode, in normal condition triggering is automatic and when push button AUTO/LEVEL pressed the trigger level can be set with the help of encoder. LED : indication for triggered signal in frequency counter mode. User Manual SM5074/ SM5075...
  • Page 11 10 Vpp respectively when terminated with 50 .(For Pulse, the output is 10 Vpp in open circuit and 5 Vpp when terminated in 50 ) MOD GEN : When pressed AM generator mode is selected 5075). User Manual SM5074/ SM5075...
  • Page 12: Rear Panel Controls

    Rear Panel Controls SM5074 /600W Scientific Mes- Technik Pvt. Ltd. B- 14, Pologround Industrial Estate Indore 452015, India SM5074 Power : 230 V, 50 Hz Watts : 30 VA, (approx) Fuse : 0.2 A, time lag, 5x20 mm AM/FM/PWM SM5075...
  • Page 13 (BNC connector) TTL output synchronous to signal output. Mains : Mains input 230 V AC 50 Hz 10%. ± Fuse : Mains fuse assembly. Spare fuse for mains inside. AM OUT (BNC connector): Internal Modulation Generator Output. User Manual SM5074/ SM5075...
  • Page 14: Operating Instructions

    Operating Instructions General Information The logical front panel layout of SM5074/ SM5075 ensures rapid familiarization with the various functions. However, even experienced operators should not neglect to carefully read the following instructions, to avoid any operational errors and to be fully acquainted with the instrument when later in use.
  • Page 15: First Time Operation

    Procedure- Connect AC Power mains into receptacle on rear panel and plug into AC inlet. Switch ON the RED Power ON switch of SM5074/ SM5075 On switching, self test will be displayed and the last settings will be set. The desired frequency is selected by pressing FREQUENCY push button &...
  • Page 16: Modulation

    In high signal voltage ranges it should be noted that the used terminating resistor must dissipate the corresponding effective power. The output terminal of SM5074/ SM5075 is short circuit proof. If the output of the SM5074/ SM5075...
  • Page 17: Am Standard

    Connect an AC modulating signal with no DC component to the AM/FM/PWM input BNC on rear panel of SM5074/ SM5075 Select AMBAL mode by pressing MODULATION pushbutton Adjust amplitude of the AC modulating signal for the desired Amplitude Modulation. User Manual SM5074/ SM5075...
  • Page 18: Frequency Modulation

    AM Balance Frequency Modulation The modulating signal is applied to SM5074/ SM5075 AM/FM/PWM input & FM mode is selected by MOD pushbutton, then this function generator can be used as FM Signal Generator. Procedure - Set up the instrument as described in function generator operation. Use t h e frequency and amplitude mode to set the carrier to the desired frequency and amplitude.
  • Page 19: Pulse Width Modulation

    The input signal applied from rear panel is modulating signal and the carrier frequency is the function generator frequency which may go up to 3 MHz. In this type of modulation the amplitude of pulse varies according to the amplitude of modulating signal wave shape. User Manual SM5074/ SM5075...
  • Page 20: External Control Vcf

    If a positive DC voltage is applied to the AM/FM/PWM input on the rear BNC of SM5074/ SM5075 & FM mode is selected by MOD pushbutton, the generator frequency increases, a negative DC voltage reduces the frequency. In this way SM5074/ SM5075 can be used as External VCF Signal Generator.
  • Page 21: Internal Modulation Generator

    0.3 Hz to 3 MHz. Operation is very easy and is confined to the setting of sweep- speed and sweep-width. Procedure - Set up equipment as for Function generator operation. Select the highest & lowest frequency to be swept with START/STOP switch. User Manual SM5074/ SM5075...
  • Page 22: Dc Offset

    The trigger output is short-circuit proof and can drive several TTL inputs. Use as External Frequency Counter Your SM5074/ SM5075 can used independently as Frequency Counter up to 40 MHz. Procedure - Press COUNTER push button, which converts instrument into external frequency counter.
  • Page 23: Maintenance

    . The rating of the fuse is 200 mA , 250 V , slow blow , 5x20 mm glass fuse. Do not use a fuse with a higher value other wise it may damage the instrument in case, the mains voltage goes much higher than the rating of the mains fluctuation of 10%. User Manual SM5074/ SM5075...
  • Page 24: Dispatch Procedure For Service

    Dispatch Procedure For Service No user serviceable parts are inside the instrument , should it become necessary to send back the instrument to factory for service,please observe the following procedure. Before dispatching the instrument please write to us giving full details of the fault noticed.
  • Page 25: Warranty Conditions

    Warranty Conditions Scientific warrants all its Instruments to be free from defects in material and workmanship when used under normal operating conditions in accordance with the instructions given in the manual for a period of 12 (Twelve) months from date of purchase from Scientific or its authorised dealers. The service during the warranty period will be rendered on return to factory /service center basis.
  • Page 26 Notes User Manual SM5074/ SM5075...
  • Page 27 Notes User Manual SM5074/ SM5075...
  • Page 28 Major Service Centers Phone / Fax / Email Scientific Mes-Technik Pvt. Ltd., Ph : (0731) 2309741,2422330-31 92, Electronics Complex, Fax :(0731)2422334, 2561641 Pardeshipura, info@scientificindia.com Indore M. P. 452 010 Scientific Mes-Technik Pvt. Ltd., Ph : (011) 65638100, 65638101 B-13, D.S.I.D.C Packging Complex Fax:(011)26536298 Kirti Nagar, New DelhiI 110 015 ndelhi@scientificindia.com...

This manual is also suitable for:

Sm5075

Table of Contents