Dostmann Electronic 5040-0242 Instructions For Use Manual

Measuring instruments to measure ph, mv, conductivity, tds, salinity and temperature
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Bedienungsanleitung
2 - 15
Instruction for Use
16 - 28
Tester Kit Serie
Messgeräte-Sets zur Messung von
pH, Redox, Leitfähigkeit, TDS, Salzgehalt und Temperatur
Measuring instruments to measure
pH, mV, Conductivity, TDS, Salinity and Temperature
5040-0242 / 5040-0243 / 5040-0244 / 5040-0245 /
5040-0240 / 5040-0241
www.dostmann-electronic.de

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5040-0242 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dostmann Electronic 5040-0242

  • Page 1 16 - 28 Tester Kit Serie Messgeräte-Sets zur Messung von pH, Redox, Leitfähigkeit, TDS, Salzgehalt und Temperatur Measuring instruments to measure pH, mV, Conductivity, TDS, Salinity and Temperature 5040-0242 / 5040-0243 / 5040-0244 / 5040-0245 / 5040-0240 / 5040-0241 www.dostmann-electronic.de...
  • Page 2: Table Of Contents

    Inhaltsverzeichnis Einleitung Aufgrund der kompakten Bauweise eignet sich die Tester Serie Einleitung (nachfolgend auch als Gerät bezeichnet) besonders bei der Qualitäts- kontrolle, Instandhaltung und frühzeitigen Problemerkennung in den Bereichen der Brauchwasser Kontrolle, Landwirtschaft, Umwelt Über- Sicherheitshinweise wachung, Wasser und Abwasser Behandlung, Hydrokultur, Aquakul- tur, Aquarium, Pools, Spa, Lebensmittel und Getränke Herstellung Lieferumfang sowie bei Kühltürmen, Galvanisierung und Druckherstellung.
  • Page 3: Bedienung Des Gerätes

    Bedienung des Gerätes Inbetriebnahme des Gerätes Batterie einlegen Features Öffnen Sie das Batteriefach. Legen Sie die zwei AAA 1,5 Volt - Großes LCD-Display Batterien polrichtig ein. Schließen Sie das Batteriefach. - Anzeige der kalibrierten Bereiche (L= Low, M= Medium, H= High) - Bestätigung bei Erreichen eines stabilen Messwertes durch Smiley-Symbol auf dem LCD-Display - Automatische Temperaturkompensation - 1 oder 2-Punkt Kalibrierung (PH 1 / COND1 ) -...
  • Page 4: Messung

    Die Kalibrierung der Leitfähigkeit ist identisch, hier muss nur zuerst Ausschalten / Auto Power OFF mithilfe der MODE-Taste (7) auf den Messbereich COND Drücken Sie die ON/OFF-Taste (6 bzw. 9) für ca. 5 Sekunden um umgeschaltet werden. das Gerät auszuschalten. Das Messgerät schaltet sich automatisch 8 Minuten nach dem Eine Kalibrierung des Gerätes sollte je nach Verwendung täglich letzten Tastendruck ab.
  • Page 5: Technische Informationen

    Technische Informationen Technische Daten PH 5 / PH 5 FOOD PC 5 PH 1 COND 1 COND 5 Art.Nr. 5040-0242/5040-0243 5040-0245 5040-0240 5040-0241 5040-0244 pH Messung Messbereich: -2…16,00 pH -2…16,00 pH 0…14,00 pH Auflösung: 0,01 pH 0,01 pH 0,1 pH Genauigkeit: ±...
  • Page 6 Zubehör und Ersatzteile Leitfähigkeit Standard Lösung mit DFM / N.I.S.T-Zertifizierung in Glasflasche pH Pufferlösungen in Patent Flasche Artikel Nummer Beschreibung Artikel Nummer Beschreibung 6031-0050 1 x 300ml Leitfähigkeitslösung 5µS/cm +-0,1 / 25°C Glasfla- sche mit DFM-Zertifikat 6031-0030 1 x 250ml Pufferlösung pH 4,01 +-0,01 / 25°C rot mit N.I.S.T Zertifikat 6031-0051 1 x 300ml Leitfähigkeitslösung 5µS/cm +-0,1 / 25°C Glasfla-...
  • Page 7 Ersatzteile Elektrolyt- und Wartungs-Flüssigkeiten 6030-0042 pH Ersatz-Elektrode für PH 5 Artikel Nummer Beschreibung 6030-0043 pH Ersatz-Einstechelektrode für PH 5 FOOD 6031-0015 1 x 75ml 3M KCI Sensor Elektrolytlösung 6030-0044 COND Ersatz-Elektrode für COND 5 6031-0016 1 x 500ml 3M KCI Sensor Elektrolytlösung 6030-0045 PC Ersatz-Elektrode für PC 5 6031-0017...
  • Page 8: Leitfähigkeit Und Wasserhärte

    Leitfähigkeit und Wasserhärte Allgemeine Bestimmungen Die Leitfähigkeitsmessung erlaubt es, mit einer sehr guten Annähe- Zeichenerklärung rung, Aussagen über die Wasserhärte zu treffen. Diese wird haupt- Mit diesem Zeichen bestätigen wir, dass das Produkt sächlich durch die Präsenz von gelösten Kalzium- und Magnesium- den in den EG Richtlinien festgelegten Anforderungen Ionen in einer Flüssigkeit bestimmt. Die am häufigsten verwendete entspricht und den festgelegten Prüfverfahren unterzo- Einheit für die Wasserhärte ist das französische Härtegrad (°f), das...
  • Page 9 Table of contents Introduction Due to the compact design, these tester series is suitable especially Introduction in quality control, maintenance and early problem identification in the industrial water control, agriculture, environmental monitoring, water and waste water treatment, hydroponics, aquaculture, aquarium, Safety instructions swimming pools, spa, printing education, food and beverage manufacturing and cooling towers.
  • Page 10: Operating The Unit

    Operating the unit Putting the device into operation Insert battery Main Features Open the battery case and insert the two AAA 1,5 batteries. Make - Large LCD display sure the batteries have the correct polarity. Close the battery case. - Buffers used for calibration indication (L= Low, M= Medium, H= High) - Measurement stability indicator (smiley icon - Automatic temperature compensation - 1…2 calibration points (PH 1 / COND1 ) - 1-,2- or 3 calibration points (PH 5 / PH 5 Food / PC 5) Instrument description PH 5 / PH 5 Food / PC 5 / COND 5 PH 1 / COND 1...
  • Page 11: Measurement

    The calibration of the conductivity is identical, but you have to Power off the device switch to the measurement range COND with pressing the mode Press the ON / OFF button (6/9) for approximately 5 seconds to button (7). power off the device. The device automatically switches itself off 8 minutes after the last The calibration of the instrument should be performed daily before keypress. starting the measurement. If you don´t calibrate regularly, perform it before each measurement.
  • Page 12: Technical Information

    Technical information technical data PH 5 / PH 5 FOOD PC 5 PH 1 COND 1 COND 5 Ord.No. 5040-0242/5040-0243 5040-0245 5040-0240 5040-0241 5040-0244 pH measurement Measuring range: -2…16,00 pH -2…16,00 pH 0…14,00 pH Resolution: 0,01 pH 0,01 pH 0,1 pH Accuracy: ±...
  • Page 13 Accessories and spare parts Conductivity standard solutions DFM / N.I.S.T- Certificate in glass bottle pH buffer solution N.I.S.T- Certificate in patent bottle Order No. Description Order No. Description 6031-0050 1 x 300ml conductivity solution 5µS/cm +-0,1 / 25°C glass bottle with DFM certificate 6031-0030 1 x 250ml buffer solution pH 4,01 +-0,01 / 25°C red color with N.I.S.T Zertifikat...
  • Page 14: Conductivity And Water Hardness

    Conductivity and water hardness Electrolyte and maintenance fluids Order No. Description The conductivity measurement allows to make statements about the water hardness with a very good approximation. This is mainly 6031-0015 1 x 75ml 3M KCI sensor electrolyte solution determined by the presence of dissolved calcium and magnesium 6031-0016 1 x 500ml 3M KCI sensor electrolyte solution ions in a liquid.
  • Page 15: General Provisions

    General provisions Explanation of symbols This sign certifies that the product meets the requirements of the EEC directive and has been tested according to the specified test methods. Disposal This product has been manufactured using high-grade materials and components which can be recycled and reused. Never dispose of empty batteries and rechargeable batteries in household waste. As a consumer, you are legally required to take them to your retail store or to an appropriate collection site depending on national or local regulations in order to protect the environment.
  • Page 17 DOSTMANN electronic GmbH Mess- und Steuertechnik Waldenbergweg 3b D-97877 Wertheim-Reicholzheim Germany Phone: +49 (0) 93 42 / 3 08 90 Fax: +49 (0) 93 42 / 3 08 94 E-Mail: info@dostmann-electronic.de Internet: www.dostmann-electronic.de Technische Änderungen vorbehalten ● Nachdruck auch auszugsweise untersagt Stand04 1809CHB ● © DOSTMANN electronic GmbH Technical changes, any errors and misprints reserved ● Reproduction is prohibited in whole or part Stand04 1809CHB ● © DOSTMANN electronic GmbH...

This manual is also suitable for:

5040-02435040-02445040-02455040-02405040-0241

Table of Contents