Contents:
1.
Introductory Remarks ......................................................................................................... 2
2.
Application........................................................................................................................... 2
3.
Reservations of Producer ................................................................................................... 2
4.
Technical Data ..................................................................................................................... 3
5.
Structure and Function ....................................................................................................... 4
6.
Assembly and Start-up ....................................................................................................... 5
7.
Operational Use ................................................................................................................... 7
8.
Troubleshooting Guide ..................................................................................................... 10
9.
Maintenance ...................................................................................................................... 10
10.
Occupational Health and Safety ....................................................................................... 10
11.
Transport and Storage ...................................................................................................... 11
12.
Terms of warranty ............................................................................................................. 11
13.
Sample of the Declaration of Conformity ........................................................................ 12
17.10.2019
1
MATRIX-1000-W
800O56 MATRIX-1000-W-1-S
800O57 MATRIX-1000-W-1-A
800O58 MATRIX-1000-W-2-S
800O59 MATRIX-1000-W-2-A
filtering unit MATRIX-1000-W
17.10.2019/EN
17.10.2019/EN
17.10.2019/EN
17.10.2019/EN

Advertisement

Table of Contents
loading

Summary of Contents for Klimawent MATRIX-1000-W Series

  • Page 1: Table Of Contents

    Use and Maintenance Manual MATRIX-1000-W Filtering unit Manufacturer: KLIMAWENT S.A. 81-571 Gdynia; ul. Chwaszczyńska 194 phone 58 629 64 80; 58 771 43 40 800O56 MATRIX-1000-W-1-S 17.10.2019/EN phone 58 629 64 80 800O57 MATRIX-1000-W-1-A 17.10.2019/EN e-mail: klimawent@klimawent.com.pl 800O58 MATRIX-1000-W-2-S 17.10.2019/EN www.klimawent.com.pl...
  • Page 2: Introductory Remarks

    1. Introductory Remarks The purpose of the present Use and Maintenance Manual is to supply User with directions wi- thin the range of application, installation, start-up and the use of the MATRIX-1000-W f ilte- ring unit . Installing, start up and operational use are exclusively admissible after getting acquaint- ted with the contents of the Use and Maintenance Manual.
  • Page 3: Technical Data

    5. Servicing and any repair activities can exclusively be carried out by an authorized person. 6. Do not use the device for conveying the air containing viscous and aggressive impurities that would damage the filters, as well as for dusts that would create explosion hazard. 7.
  • Page 4: Structure And Function

    Fig. No.2 – MATRIX-1000-W – Structure 5. Structure and Function MATRIX-1000-W filtering unit consists of following elements: ● housing – polyester-glass composite, ● radial fan – zinc-coated steel sheet, ● cartridge filter – polyester fabric, ● dust container with a plug, ●...
  • Page 5: Assembly And Start-Up

    In the filtering unit is installed a pressure control (pressostat) that activates the signalling lamp – indicating the need of filter regeneration , (in case of manual control), or indicating the neces- sity of filter replacement, in case of automatic control. Under the filter is located a fabric container, collecting the dusts dropping from the filter, after regeneration.
  • Page 6 Fig. No.5 – Connection diagram – filtering unit MATRIX-1000-W-S filtering unit MATRIX-1000-W 17.10.2019...
  • Page 7: Operational Use

    Fig. No.6 – Connection diagram – filtering unit MATRIX-1000-W-A 7. Operational Use For application of the device at a mobile welding post – see Phot. No.1. In to process of filter regeneration, the dust particles are accumulating on the external surface of the filter. From there the dust particles are periodically truck off by the compressed air, supplied from the rotary jets (nozzles).
  • Page 8 Photo No.1 – MATRIX-1000-W-1 – Application The standard version (MATRIX-1000-W-1-S and MATRIX-1000-W-2-S) – when the lamp of the pressure control (pressostat) lights on – or the flow efficiency decreases – switch off the device, wait until the fan impeller stops rotating. Subsequently, open the ball valve of the com- pressed air installation, slide the lance with rotary jets up and down –...
  • Page 9 The dust accumulated in the container, placed under the filter (in the lower part of the filtration chamber). The container has to be emptied periodically. In order to do this, remove the cover along with the lance (open the 4 clasps). Subsequently, pull out the filter (see Phot. No.5). In case of automatically controlled device MATRIX-1000-W-A, first take off the coil of the ele- ctromagnetic valve with the cable and then open the clasp fasteners.
  • Page 10: Troubleshooting Guide

    Take out the bag from the device body by gripping at the four handles (in the upper part of the bag ). After the container is emptied of the dust, the cover must be removed and fastened at the device body and additionally secured by hook and loop fasteners. The plug should be stored in the control chamber.
  • Page 11: Transport And Storage

    To get the access to the connection box, it is important to unscrew the mounting screws (faste- ning the cover of the control chamber) and to disassemble the cover from the device. ERGO LUX extraction arms shall not cause any hazard, under the condition that they are stably installed on the housing of the filtering unit.
  • Page 12: Sample Of The Declaration Of Conformity

    Declaration of conformity EC No. …………….. Manufacturer (eventually the authorized representative / importer): name: KLIMAWENT S.A. address: 81-571 Gdynia, Chwaszczyńska 194 A person, authorized for issuing the technical documentation: Teodor Świrbutowicz, KLIMAWENT S.A. hereby declares that the appliance: name: filtering unit...

Table of Contents