ONNLINE Thermostat 105 Manual

For floor heating

Advertisement

Available languages

Available languages

Quick Links

Onnline
Onnline Thermostat 105 is an electronic thermostat with an
external floor sensor and a built in temperature sensor so it can
be used as room thermostat or floor heating system controller.
1.SPECIFICATION:
Power source:
Relay contact:
Temperature setting range:
Limit of temperature:
:
Color
2.IMPORTANT SAFETY INFORMATION:
● Only professional contractor should install this thermostat
Read all of the information in this manual before installing
the thermostat.
Always turn off power at the main power source by
unscrewing fuse or switching circuit breaker to the off
position before installing, removing, cleaning, or servicing
this thermostat
All wiring must conform to local and national building and
electrical codes and ordinances.
Maximum floor temperature has to be limited to be 27
the sensor has to be set as Fig 3 (Both senor) when it is
applied on wooden floor.
3.INSTALLATION:
Wire Diagram (fig.1)
1
Mounting of thermostat
1. Lift off the front cover as Fig.2.
2. Follow the wire diagram above for the electrical connection.
(
3. Put the thermostat
circuit board
.
screw it into the wall
4. Mount the wall frame, fit the cover in place and press so that
the fastening hooks snap into place and make sure that the
temperature knob is correctly placed. Please refer to the fig 3.
-
,
;
230VAC +/- 10%
50
Hz
250VAC 16A
℃(
)
5
to
35
0-10
+
27
White
2
1
Heating load
2
Temperature sensor
Fig. 2
)
to the wall box and
Onnline Thermostat 105 for Floor Heating
Setting the temperature knob in place (fig.3):
/
60
Hz
Turn the handle clockwise
to tighten it.
Choosing the sensor
Onnline thermostat 105
connecting an external sensor as main sensor or min/max limiting
sensor. The three working modes of the thermostat are controlled
by the terminal points: K1 and K2 on the circuit board Make
sure that the power is off before the adjustment is taken
1. External sensor only factory setting
and
Only connect K2. External sensor is used as main sensor.
When the external sensor doesn't work, the thermostat will
connect the inner sensor automatically. When neither of the
sensors works,the thermostat will go to safe mode automatically.
2. Inner sensor only
Connect both K1 and K2. Only inner sensor is used.
When the inner sensor doesn't work, the thermostat will go to
safe mode automatically.
3. Both sensors Fig. 3
Connect neither of the points. Both sensors are used
The inner sensor works as temperature controlling sensor while
the external sensor works as the temperature limiting sensor.
No matter how to adjust the set-point on knob, the temperature
of the sensor will be limited to be under 27 . When one of the
sensors doesn't work, the thermostat will go to safe mode
automatically and the maximum working power will just be
80% of the original one.
This product meets the requirement of European Council s
directive 89/336, EN61000-6-3, EN
CE marking
LVD
This product meets the requirements of European LVD 73/23,
EN60730-1 and EN60730-2-9.
Make the 10 on the dial point
at "
" , then press it down.
has a built-in sensor and terminals for
(
(
)
Fig. 2
(
)
( with maximum temperature limiting function)
EMC emissions & immunity standards:
61000-6-2
.
.
.
(
)
)
Fig. 1
'
and it carries

Advertisement

loading

Summary of Contents for ONNLINE Thermostat 105

  • Page 1 Onnline Onnline Thermostat 105 for Floor Heating Onnline Thermostat 105 is an electronic thermostat with an Setting the temperature knob in place (fig.3): external floor sensor and a built in temperature sensor so it can be used as room thermostat or floor heating system controller.
  • Page 2 Onnline Onnline Termostat 105 for gulvarme Montering av temperaturhjul (fig.3) Onnline termostat 105 er en elektronisk termostat med ekstern gulvføler og en innebygd romføler. 1. SPESIFIKASJONER: Driftsspenning 230VAC+/-10 %; 50Hz / 60Hz Hovedstrømbryter 2-polet Temperaturområde 5C til 35C (0-10) ℃...