DO NOT use a naked flame to try and ignite the heater.
DO NOT use the heater near flammable, combustible or explosive materials - liquids, solids or gases.
DO NOT leave the heater unattended whilst in use.
DO NOT obstruct the air inlet and outlet sections of the heater. Keep immediate area clean and tidy.
DO NOT point the heater towards the gas cylinder.
Keep children away from the heater.
Keep the heater clean and in good working order.
Ensure that the heater is correctly turned off and the gas source isolated when not in use.
When not in use for any length of time, store heater in a safe, dry, childproof location.
NOTE: This appliance is not intended for persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the appliance.
2. INTRODUCTION
Many users have found the advantages of propane heaters far outweigh the small additional running costs. The fuel is more completely burned
and does not leave an oily residue as experienced with paraffin heaters. There is no odour, except for the few seconds during start-up and the
units run a little more quietly since they do not need a compressor to drive the fuel to the burner. Available with a durable paint finish or with a
stainless steel body for improved corrosion resistance and stylish appearance.
Heaters are fan assisted, fitted with a piezoelectric ignition system for trouble-free starting and feature a direct gas head assembly. Safety
solenoids prevent the heater from leaking gas without first being electrically started. Supplied with an approved propane gas regulator and hose.
All models are tested and certified to CE/EN. Manufactured to BS EN 1596.
3. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .LP41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LP55
Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.5kW . . . . . . . . . . . . . . . . . . . . . . . . . . . 16kW
Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40,500Btu/hr . . . . . . . . . . . . . . . . . 54,500Btu/hr
Airflow: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300cfm . . . . . . . . . . . . . . . . . . . . . . . . . .300cfm
Fuel Consumption: . . . . . . . . . . . . . . . . . . . . . . .0.91kg/hr. . . . . . . . . . . . . . . . . . . . . . . 1.32kg/hr
Supply:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V
Length:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .385mm . . . . . . . . . . . . . . . . . . . . . . . . . .460mm
Width:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .215mm . . . . . . . . . . . . . . . . . . . . . . . . . .230mm
Height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .325mm . . . . . . . . . . . . . . . . . . . . . . . . . .310mm
Fuel:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Propane . . . . . . . . . . . . . . . . . . . . . . . . Propane
Heated Area: . . . . . . . . . . . . . . . . . . . . . . . . . . . .6850ft³ . . . . . . . . . . . . . . . . . . . . . . . . . 9,500ft³
Heated Area: . . . . . . . . . . . . . . . . . . . . . . . . . . . .194mtr³ . . . . . . . . . . . . . . . . . . . . . . . . . 275mtr³
Weight:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.25kg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6kg
4. INSTALLATION
Note: If a small gas cylinder is used, the heater may not operate at maximum efficiency. It is recommended to use two or more cylinders
linked in parallel, to achieve maximum continuous efficiency (fig.3).
4.1.
Connections
4.1.1. Check heater and gas cylinder to ensure that they are both in good condition. If not, stop and contact your supplier immediately.
4.1.2. Site the heater and gas cylinder in the location to be heated.
4.1.3. Connect the heater to an electrical supply outlet, ensuring that the machine is earthed correctly. See safety instructions.
4.1.4. Connect the gas supply hose to the pressure regulator, and connect the regulator to the gas cylinder. Note: Left hand threads are used on
these fuel gas fittings.
4.1.5. Connect the other end of the gas supply hose to the heater's gas inlet connection (fig.2). Ensure all connections are tight.
4.1.6. Gradually open the tap of the gas cylinder. Check hose and all fittings for gas leaks. Close gas tap if gas is present
WARNING! DO NOT USE A NAKED FLAME To check for leaks, we recommend the use of a foamy soap solution.
fig.1
IMPORTANT: To ensure continuous ventilation to the heater area, a ventilation opening must connect to the outside of the premises where the heater is to
operate. The opening must be 100cm
4.2.
Turning heater on.
4.2.1.
Switch on/off switch (fig.1) to 'on'. Check that the fan is running.
4.2.2.
Press the override button.
4.2.3.
Click the peizo igniter button repeatedly until the gas is heard to ignite.
4.2.4.
Keep the override button depressed for at least 10 seconds and then release.
4.2.5.
The flame should stay lit at this point. If it does not hold, repeat from 4.2.2.