Eco MC-11 Instruction Manual

Eco MC-11 Instruction Manual

Signal converter a-box

Advertisement

Quick Links

INSTRUCTION MANUAL
4-20mA Converter
A-Box
Version Number: 1
 
Tel.: +11 3976-4003 • 3999-7737
vendas@romiotto.com.br
www.romiotto.com.br

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MC-11 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eco MC-11

  • Page 1 INSTRUCTION MANUAL 4-20mA Converter A-Box Version Number: 1   Tel.: +11 3976-4003 • 3999-7737 vendas@romiotto.com.br www.romiotto.com.br...
  • Page 2: Table Of Contents

    8 - 2 . U S B C o n t r o l l e r a n d c o n f i g u r a t o r s o f t w a r e 1 5   8 - 3 . D i m e n s i o n s Pg. 1 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 3: Important User Information

    Any modification or repair was done by any person or organization other than EKO service personnel. Ø The damage or defect is caused by not respecting the instructions of use as given on the product brochure or the instruction manual. Pg. 2 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 4: A B O U T I N S T R U C T I O N M A N U A L

    RoHS Directive 2002/95/EC at concentration levels in excess of those permitted under the RoHS Directive 2002/95/EC, or up to levels allowed in excess of these concentrations by the Annex to the RoHS Directive 2002/95/EC. Pg. 3 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 5: C E D E C L A R A T I O N

    Amendment to the above directive: 93/68/EEC Date: Mar. 6, 2015 Position of Authorized Signatory: Deputy General Manager of Quality Assurance Dept. Name of Authorized Signatory: Shuji Yoshida Signature of Authorized Signatory: Pg. 4 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 6: Safety Information

    3 - 2 . H I G H V O L T A G E W A R N I N G 1. Power Supply Ø Always check the DC voltage for the specified supply power before connecting the 4-20mA Converter (12 – 24 VDC). Pg. 5 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 7: Introduction

    USB controller and EKO sense software. • • • • • • • • • • • Tel.: +11 3976-4003 • 3999-7737 • vendas@romiotto.com.br • www.romiotto.com.br • • • • • • Pg. 6 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 8: P A C K A G E C O N T E N T S

    Quick Start Guide   Optional Items Qty. Remarks USB Controller 1 unit 1m with clamps Connecting cable 1 pc.   On USB memory stick Software 1pc. Quick Start Guide Pg. 7 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 9: Getting Started

    4-20mA Output & Power Supply Input Terminal ( - ) 4-20mA Output & Power Supply Input Terminal ( + ) Ground terminal Tel.: +11 3976-4003 • 3999-7737 vendas@romiotto.com.br www.romiotto.com.br Pg. 8 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 10: S E T U P

    12 VDC, which is needed to feed the internal electronics. In case of very long cables the voltage loss across the cable must be compensated (24 VDC supply voltage recommended). Figure 5-2. Wiring current output (4-20mA) Pg. 9 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 11 Even tough the output terminals are protected against surge a fuse can be applied in addition. ※ Example for a 0-1V measurement device and 50Ω precision shunt resistance. Figure 5-3. Wiring Voltage output (0.2 – 1V) Pg. 10 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 12: M E A S U R E M E N T

    When 500Ω resistance is used, the voltage at the both ends of the shunt resistance would be 2V to 10V, and it is equivalent to 0 to 1600W/m Pg. 11 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 13: Usb Controller / Software

    Connect the USB controller to a PC and connect the red (+) and black clamp (-) to the output to the sensor output of the 4-20mA Converter. Power will be supplied from the USB port. Figure 5-3. Wiring USB Controller) Pg. 12 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 14: O P E R A T I N G

    5. Sensor output can be tested through the Read function (mV, Irradiance W/m , temperature (Only when a temperature sensor (NTC 10kΩ) is connected)). Setting files can be saved (Save) or printed (Report). Pg. 13 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 15: Troubleshooting

    (Synchronized or Not Synchronized) Read function doesn’t display any Check the connection measured data Tel.: +11 3976-4003 • 3999-7737 vendas@romiotto.com.br www.romiotto.com.br Pg. 14 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 16: Specifications

    8 - 2 . U S B C o n t r o l l e r a n d c o n f i g u r a t o r s o f t w a r e Table 8-2. USB Controller USB Controller / EKO Sense software Windows 7, 8 Weight 0,05 kg Cable 1m / gator clamps Pg. 15 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 17 8 - 3 . D i m e n s i o n s Unit (mm) Figure 8-1. Dimensions Figure 8-2. Box Dimensions Tel.: +11 3976-4003 • 3999-7737 vendas@romiotto.com.br www.romiotto.com.br Pg. 16 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...
  • Page 18 Japan: www.eko.co.jp Europe: www.eko-eu.com USA: www.eko-usa.com Pg. 17 EKO INSTRUMENTS CO., LTD. 4-20mA Signal Converter MC-11 Instruction Manual V1...

Table of Contents