FAAC XGUARD-5H User Manual

FAAC XGUARD-5H User Manual

Laser scanner for barriers & gates

Advertisement

XGUARD-5H
LASER SCANNER FOR BARRIERS & GATES
with max. detection range of 5.0 m x 6.5 m
User's Guide
for product version 0100 and more
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XGUARD-5H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FAAC XGUARD-5H

  • Page 1 XGUARD-5H LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m User’s Guide for product version 0100 and more...
  • Page 2: Installation And Maintenance

    SAFETY The device contains IR and visible laser diodes. IR laser: wavelength 905nm; max. output pulse power 75W (Class 1 according to IEC 60825-1) Visible laser: wavelength 650nm; max. output CW power 3mW (Class 3R according to IEC 60825-1) The visible laser beams are inactive during normal functioning. The installer can activate the visible lasers if needed.
  • Page 3 DESCRIPTION laser connector sweep emission protection cover laser sweep reception visible laser beam (3) LED-signal (4) notch for tilt angle adjustment (2) screw for position lock (2) adjustable bracket LED-SIGNAL 1. Detection LED: relay 1 - opening field LED flashes quickly 2.
  • Page 4: How To Use The Remote Control

    HOW TO USE THE REMOTE CONTROL After unlocking, the first LED If the red LED flashes quickly after unlocking, you To end an adjustment session, flashes red and the sensor need to enter an access code from 1 to 4 digits. always lock the sensor.
  • Page 5 MOUNTING 40 cm (recommended) Keep the front face of the sensor free! Do not cover with glass or plastic. front view d (mm) distance between (mm) (mm) laser and opening side view Use the LBA mounting support Position the bracket and fasten Open the protection cover, plug for installation on the pole.
  • Page 6 WIRING GREEN POWER SUPPLY + Use the Power Supply Module (24V DC, 0.75 A) if needed. BROWN POWER SUPPLY - WHITE RELAY 1 - OPENING FIELD YELLOW The sensor tests both relays. PINK RELAY 2 - SAFETY FIELD VIOLET TEST + No test function: connect red and blue wires to TEST -...
  • Page 7 MOUNTING SIDE RIGHT LEFT Choose the correct mounting side: LEFT or RIGHT right left right left WITHOUT WITH REFERENCE POINT REFERENCE POINT (surface of min. 15 cm) The sensor will automatically adjust the safety field on the basis of the reference point if C = 00.
  • Page 8 SAFETY FIELD - PRESENCE WIDTH 6.5 m TEACH-IN The safety field can be adapted more precisely by launching a teach-in (the sensor learns the environment). Before launching a teach-in, make sure that the selected field size is bigger than the desired field size. The detection field should be free of snow buildups, heavy rain, snowfall, fog or other moving objects.
  • Page 9 OPENING FIELD - MOTION same width as safety field TEACH-IN The opening field can be adapted more precisely by launching a teach-in (the sensor learns the environment). Before launching a teach-in, make sure that the selected field size is bigger than the desired field size. The detection field should be free of snow buildups, heavy rain, snowfall, fog or other moving objects.
  • Page 10 REMOTE CONTROL ADJUSTMENTS (OPTIONAL) MIN. DETECTED OBJECT SIZE opening field approximate values MAX. PRESENCE TIME opening field 10 s 30 s 1 min 2 min 5 min 10 min infinite During detection, the sensor automatically switches from motion to presence detection for a given presence time.
  • Page 11: Output Configuration

    REMOTE CONTROL ADJUSTMENTS (OPTIONAL) DETECTION DELAY opening field approximate values SAFETY FIELD REDIRECTION motion or motion + motion RELAY 1 presence presence presence presence presence RELAY 2 R1 R2 OUTPUT CONFIGURATION RELAY 1 A - NO P - NC P - NC A - NO A = active P = passive...
  • Page 12: Troubleshooting

    TROUBLESHOOTING There is no power. No blue LED Check cable and connexion. The polarity of the power Check the polarity of the power supply. supply is inverted. All LEDs have been de- Activate the LEDs by remote control. activated by remote control. Check the size of the fields.
  • Page 13: Technical Specifications

    TECHNICAL SPECIFICATIONS Technology: laser scanner, time-of-flight measurement Detection mode: motion and presence Max. detection range: 5.0 m x 6.5 m Remission factor: > 2 % Angular resolution: 0,3516 ° Emission characteristics IR laser: wavelength 905 nm; max. output pulse power 75 W (CLASS 1) Red visible laser: wavelength 650 nm;...
  • Page 16 FAAC S.p.A . - Via Calari, 10 40069 Zola Predosa - Italia - tel. +39 051 61724 - fax. +39 051 758518 - www.faacgroup.com BEA hereby declares that the XGUARD-5H is in conformity with the basic requirements and the other relevant provisions of the directives 2014/35/EU, 2011/65/EU and 2014/30/EU.