Download Print this page

Dataprobe K-4 Series Manual

Remote control

Advertisement

Quick Links

Overview
The K-4xx and K-8xx series AC power strips provide multiple switched outlets that can be remotely controlled
from one of Dataprobe's many remote control systems or from any device providing a contact closure. The
following models are covered in this manual.
K-820
8 switched outlets, for use on 115 VAC, 20 Amp Service – NEMA N5-20
K-420
4 switched outlets, for use on 115 VAC, 20 Amp Service – NEMA N5-20
K-815
8 switched outlets, for use on 115 VAC, 15 Amp Service – NEMA N5-15
K-415
4 switched outlets, for use on 115 VAC, 15 Amp Service – NEMA N5-15
K-810
8 switched outlets, for use on 115/230 VAC, 12 /10 Amp International – IEC 320
K-410
4 switched outlets, for use on 115/230 VAC, 12 /10 Amp International – IEC 320
Throughout this manual the K-815 will be used to represent for all units, except where a distinct
reference is made.
115/230VAC
Selector Switch
On Side
REF: PWR\K8xx_UL_V020523D.DOC
1 2 3 4 5 6 7 8
Power
1 2 3 4
Power
Technical Support Hotline: (201) 934-5111
Technical Support: 201-934-5111
Main: 201-934-9944
Remote Control Power Strip
Models K-820, K-815, K-810
K-420, K-415 & K-410
K-820 & K-815, 115VAC
8 NEMA Outlets Switched
K-420 & K-415, 115VAC
4 NEMA Outlets Switched
K-810 , 115 / 230 VAC
8 IEC 320 Outlets Switched
K-410 , 115 / 230 VAC
4 IEC 320 Outlets Switched
Front Panel
All 8 Outlet Versions
Outlet Status and Power Input Status LEDs
Front Panel
All 4 Outlet Versions
Outlet Status and Power Input Status LEDs
tech@dataprobe.com
Website: dataprobe.com

Advertisement

loading

Summary of Contents for Dataprobe K-4 Series

  • Page 1 The K-4xx and K-8xx series AC power strips provide multiple switched outlets that can be remotely controlled from one of Dataprobe’s many remote control systems or from any device providing a contact closure. The following models are covered in this manual.
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS When using this product, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: Read and understand all instructions. Follow all warnings and marked on the product. Unplug this product from the wall outlet before cleaning.
  • Page 3 Feedback #s 1 – 4 See Wiring detail below. . If your controller does not use this cable, you will need to build one or order an additional cable from Dataprobe. Refer to the control wiring details below for cable specification.
  • Page 4 ( Viewed from rear panel). Make sure the switch is in the proper position before applying power. The K-810 uses IEC320 connectors for the switched output. Dataprobe offers IEC to IEC jumper cables to assist in connection to PC, Router, etc that has IEC Connection...
  • Page 5: Specifications

    Series K-x20, K-x15 & K-x10 Page 5 SPECIFICATIONS Physical 19” wide x 6.25” deep x 1.75” high, EIA Rack Mount -1RU Weight: 5 Lbs. INDICATORS: Power : On = Power applied to the unit 1 - 8 On = Power on to outlet specified Power Model K-820 &...
  • Page 6: Warranty

    Page 6 TECHNICAL SUPPORT, RETURNS and WARRANTY Dataprobe Technical Support is available 8:30AM to 5:30PM ET to assist you in the installation and operation of this product. To obtain Technical Support call our Tech Support Hotline at 201-934-5111, or Email us at tech@dataprobe.com. Please have the following information available when you call: •...

This manual is also suitable for:

K-8 seriesK-820K-815K-810K-420K-415 ... Show all