INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, EXPOSURE TO EXCESSIVE UV
GENERAL
1. To insure the success of the fixture installation, the following instructions and diagram(s) should be read and
understood. All electrical connections must be made in accordance with the National Electric Code and local
codes and ordinances.
ONLY A QUALIFIED LICENSED ELECTRICIAN SHOULD INSTALL THIS FIXTURE
2. Eco-Downlight recessed housings are UL listed for damp locations and suitable for installation with properly
installed insulation. The housings are equipped with at thermal cutoff to insure safe and reliable operation.
3. DO NOT use any other LED light engine other then the TROYCSL-EDL-WW-2
4. Bypassing the thermal cutoff or other modifications to this fixture will violate the National Electric Code, UL
regulations and void warranty
5. Insulation MUST NOT be placed in direct contact with ANY part of the fixture. A MINIMUM OF 3" OF
SPACING MUST BE MAINTAINED AND NO INSULATION MAY BE INSTALLED ABOVE THE
HOUSING
6. ELV dimmer compatible, Lutron maestro ELV dimmer not compatible
INSTALLATION PREPARATION:
1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH THE LIGHTING FIXTURE IS TO BE
ATTACHED.
Move the circuit breaker to the "OFF" position or completely remove the fuse controlling the circuit.
2.
Mark the location of all fixture openings in the layout. The fixture housing may be rotated to any position to allow for
the correct placement of the fixtures in most situations
correct placement of the fixture it should be brought to the attention of a general contractor.
location of the fixtures may adversely affect the final room illumination or lighting effect and cause costly
rework
NOTE: A 3-3/4" HOLE SAW IS RECOMMENDED FOR MAKING A CLEAN AND ACCURATE HOLE IN THE
CEILING
FIXTURE HOUSING INSTALLATION
1. Remove the remodel housing from the plaster frame
2. Securely mount the plaster frame to the building structure so that the bottom of the housing are even with the bottom
surface of the joists or other supporting structures.
3. Pull conduit through plaster frame housing hole then dry wall
4. Make all connections in accordance with NEC and local codes
5. Fasten ground wire to the green wire in the fixtures splice box using a UL approved wire nut. NEVER FASTERN
THE GROUND WIRE TO THE BLACK OR "HOT" WIRE!
6. Fasten the white fixture lead to the white wire in the splice box. Fasten the wires together with an UL approved wire
nut. Starting 1" below the wire nut, tightly wrap the connection with electrical tape so that the tape seals the end of the
wire nut. MAKE SURE THAT THERE IS NO EXPOSED WIRE OR STRANDS THAT COULD CAUSE A
DANGEROUS SHORT CIRCUIT.
7. Connect the black fixture lead to the black wire in the splice box. Fasten the joined wires as in step 4.
8. Install the housing into the plaster frame using the three black spring clips (FIG 1)
FIXTURE INSPECTION OR REPAIR
1. Depress top of mounting clips and remove one at a time (FIG 2)
2. Pull fixture down and out from the plaster frame
3. Perform maintenance or inspection (FIG 3)
4. Push fixture housing back into plaster frame and reinstall the mounting clips.
EDL-NC
PROFESSIONAL LED
RECESSED LIGHTING SYSTEM
IMPORTANT SAFETY INSTRUCTIONS
RADIATION, OR INJURY TO PERSONS
SAVE THESE INSTRUCTIONS!
. If structural or mechanical elements interfere with the
No ceiling access required!
Changing the
Need help?
Do you have a question about the Eco-Downlight EDL-NC and is the answer not in the manual?
Questions and answers