Assembly instructions Electro-mechanical systems A-opener 2.2 Inhalt INTRODUCTION .........4 Producer and service ........4 Target group of this documentation ..... 4 Intended use ..........4 Improper use ..........4 Maintenance and service notes ....4 Installation conditions and requirements ..4 Dimensions ...........
Producer and service KFV Karl Fliether GmbH & Co. KG Maintenance and service notes A company of the SIEGENIA GROUP Never use cleaning agents that are aggressive or con- Siemensstraße 10 tain solvents. This could damage the surfaces of the 42551 Velbert components.
Assembly instructions Electro-mechanical systems A-opener 2.2 1.10 Applicable documents Warning notes used For the installation of the A-opener 2.2, it is essential DANGER to observe all assembly and operating instructions that are enclosed with other (optional) components. The signal word "Danger" designates an immediately threatening danger.
Assembly instructions Electro-mechanical systems A-opener 2.2 Installation conditions and require- ments The following requirements and conditions must be observed before and during installation: • Observe the specified positions and sizes for all milling and drilling dimensions within the defined tolerances. •...
Assembly instructions Electro-mechanical systems A-opener 2.2 Functions Connections and operating elements Item Function SI-BUS connection Terminal A: data interface SI-BUS (yellow) Terminal B: data interface SI-BUS (green) Terminal C: output supply voltage (- ) GND (brown) Terminal D: output supply voltage + 24 V DC (white) Analogue connection: Terminal 2: output supply voltage + 24 V DC Terminal 3: output supply voltage (-)
Assembly instructions Electro-mechanical systems A-opener 2.2 Cable and wiring diagram WARNING Risk of fatal injury from electric shock and short circuit Wrong connection of the A-opener • All-pole safety isolation should be used when routing the network connection cable on-site. •...
Page 9
Assembly instructions Electro-mechanical systems A-opener 2.2 SI-BUS connection Analogue connection SI-BUS system A B C D 2 3 4 A B C D 2 3 4 Power supply Item Name Item Name SI-BUS adapter cable Unlocking via analogue access control system Feed (shielded) Optional external unlocking (e.g.
Assembly instructions Electro-mechanical systems A-opener 2.2 Installation Installing the A-opener The A-opener 2.2 is supplied unas- sembled as standard. f Screw the A-opener to a suitable KFV multi-point lock using the 3 x M4x11 three screws included in the delivery. T 10 1.5 Nm Milling the door leaf...
Assembly instructions Electro-mechanical systems A-opener 2.2 Routing and connecting cables Various cable types are available for establishing a connection from the power supply to the A-opener and an access control system. Only use shielded cables in order to prevent interferences, which have an effect on the KFV multi-point lock with A-opener 2.2, or originate from the KFV multi-point lock with A-opener 2.2.
Assembly instructions Electro-mechanical systems A-opener 2.2 5.3.2 Via the analogue connection To obtain a connection via the analogue connection, establish a plug connection with the KFV cable. Cable identifi- KFV cable Band colour Cable colour Connection A-opener Function cation Black grey Brown Yellow...
Assembly instructions Electro-mechanical systems A-opener 2.2 Functional test f Push down the lever handle completely, all locking elements must retract completely. In order to check the functionality, the door and the door frame The latch must extend completely again after the lever must be positioned vertically.
Assembly instructions Electro-mechanical systems A-opener 2.2 Troubleshooting 6.4.1 Functional disorder of the lever handle If the lever handle does not return to its original posi- tion by itself, there is a functional disorder. f Check the routed pocket for dimensional accuracy. f Check that the lever handle is correctly seated.
Page 15
Assembly instructions Electro-mechanical systems A-opener 2.2 Technical specifications Environmental conditions Ambient temperature range in the door (according to DIN - 25 °C to + 70 °C EN 14846 class K,M,L,N,P) Relative humidity 20% to 80% (non-condensing) Protection class IP 40 Electrical data Operating voltage 24 V DC (19 V DC to 32 V DC)
Assembly instructions Electro-mechanical systems A-opener 2.2 EC declaration of incorporation Manufacturer KFV Karl Fliether GmbH & Co. KG Siemensstr. 10 D - 42551 Velbert declares that the product: Device type: Designation of type: Electromechanical drive for mul- A-opener 2.2 ti-point locks meets the following fundamental requirements: EMC Directive 2014/30/EU...