INTRODUCTION
Model
Description
5714
Outdoor 1 port EPoC Tx Adapter, 1x BNC, 1x FE RJ45, -30ºC~60ºC
5715
Outdoor 2 port EPoC Tx Adapter, 1x BNC, 2x FE RJ45, -30ºC~60ºC
PACKAGE CONTENTS
* 1x Outdoor EPoC Adapter
* 1x Gray Rubber for 6~8mm coaxial cable
IMPORTANT:
1. Use CAT5e or CAT6 UTP/STP cables and RG6 coaxial cables.
2. Please avoid using low quality cables, which will seriously limit the cabling distance and power delivery.
3. Make sure the ventilation openings on the EPoC Adapter are not blocked.
INSTALLED LOCATION:
For further protection against water ingress and high temperature , it is recommended to locate the unit where possible:
• Horizontal installation
• Shaded from sunlight & rainfall
CONNECTION
NOTE:
To disconnect a LAN cable, loosen the cable
gland and pull the cable against the socket
wall towards the side of the locking tab.
5714/5715 Outdoor EPoC Adapter
Quick Installation Guide
* 1x Quick Installation Guide
* 1x Black Rubber for 4.5~6.5mm coaxial cable
5715
1200m(3937ft)
5714
1200m(3937ft)
NOTE:
The Outdoor EPoC Adapter & Surge Protector must be
grounded using a ground wire between the ground screw and
earth ground.
5711
Surge Protector
5710
Surge Protector
IMPORTANT:
5714:
5715:
UPoE Switch
Network Switch
Ethernet w/PoE
Ethernet
Coax w/Power
Ground screw
* Make sure the grouning
resistance is lower than
0.5Ω.