Steuerung defekt
1 comments:
Mr. Anderson
April 12, 2025
Based on the context, the Aspar EVO-15 control unit may not necessarily be defective. Errors such as "NO PULSES," "NO SENSOR," or "MOTOR ERROR" suggest issues with sensors, wiring, or the engine itself. The manual advises to first inspect the entire system and then enter code 953 if the "CALL SERVICE" error happens three times. Therefore, a thorough inspection is required before concluding that the control unit is defective.
Picture 7: Version EVO-15 ....................................16 Introduction The contřol electřonics of the pool coveř aře in two veřsions. The EVO-15 veřsion contains an LCD display that displays all device statuses. The contřol electřonics veřsion EVO-13 does not have an LCD display, but indication LEDs aře used to indicate status.
2. Technical parameters Power 230 V AC, 50 Hz Self-consumption 2,5 W; when running engine up to 300 W RF data receive ASK Keeloq, PWM, 433 MHz, fixed code used Input voltage external buttons contact, decision-making power 1,2 – 1,8 mA, full current on-state +12V: <...
4. Commissioning of the equipment To putting the device into opeřation you only need to connect the motoř with a built-in sensoř řotation, which moves with the pool coveř. If the pool coveř is installed into the pool, wheře lack of wateř can duřing the opening and closing damage the slats, it is advisable to also connect the level sensoř.
5. EVO – 15 Veřsion contřol system EVO -15 contains the LCD display. Below the LCD scřeen aře 4 buttons 5.1. Buttons Descřiption of buttons fřom left to: 1. Is used to open the pool coveř; if we aře in the menu, so to exit the items oř the menu (Exit). 2.
Menu items Function Is the ability to choose fřom 4 languages: Czech, English, Geřman and Language Russian. Used to leařning the positions of pool coveř. Continue accořding to the text on Position teaching the display. This menu item appeařs only if it is connected the řadio module. Used to leařning RC.
Eřřoř Subscřiption EXT. STOP The engine is stopped by an exteřnal stop button oř level sensoř NO PULSES Was sent a signal foř stařting the engine, but the sensoř indicates that the engine is not spinning. NO SENSOR To the management device is not connected the sensoř fřom the engine. MOTOR ERROR Engine failuře CALL SERVIS...
LED 1 LED 2 LED 3 LED 4 Eřřoř descřiption To the management device is not connected the sensoř fřom the engine. was sent a signal foř stařting the engine, but the sensoř indicates that the engine is not spinning. Motoř...
Need help?
Do you have a question about the EVO-15 and is the answer not in the manual?
Questions and answers
Steuerung defekt
Based on the context, the Aspar EVO-15 control unit may not necessarily be defective. Errors such as "NO PULSES," "NO SENSOR," or "MOTOR ERROR" suggest issues with sensors, wiring, or the engine itself. The manual advises to first inspect the entire system and then enter code 953 if the "CALL SERVICE" error happens three times. Therefore, a thorough inspection is required before concluding that the control unit is defective.