Page 1
PRISM MPX2-25 Media Analysis Platform Installation and Safety Instructions 071-3738-00...
Page 2
Worldwide, visit www.telestream.net/telestream-support/video/support.htm to find contacts in your area. Warranty Telestream on behalf of itself and its Affiliates (“Telestream”) warrants that this product will be free from defects in materials and workmanship for a PRISM MPX2-25 Installation and Safety Instructions...
Page 3
(1) year from the date of shipment. If any such product proves defective during this warranty period, Telestream, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by Telestream for warranty work may be new or reconditioned to like new performance.
Page 4
Program may be used. Title to the Program and all copies thereof, but not the media on which the Program or copies may reside, shall be and remain with Telestream or others for whom Telestream has obtained a respective licensing right.
Page 5
Telestream or any third party from whom Telestream may have obtained a respective licensing right if Customer fails to comply with any term or condition and such failure is not remedied within thirty (30) days after notice hereof from Telestream or such third party.
Equipment for Measurement, Control, and Laboratory Use - Part 1: General Requirements. Sécurité CAN / CSA-22.2 NO. 61010-1-12 + Gil + Gl2 :: Exigences de sécurité pour l'électricité Matériel de mesure, de contrôle et d'utilisation en laboratoire - Partie 1: Généralités PRISM MPX2-25 Installation and Safety Instructions...
Page 8
Exigences. European Union and European Free Trade Association (EFTA) Compliance Notices This equipment may be operated in the countries that comprise the member countries of the European Union and the European Free Trade Association. These countries, listed in the following paragraph, are referred to as The European Community throughout this document: AUSTRIA, BELGIUM, BULGARIA, CYPRUS, CZECH REPUBLIC, DENMARK, ESTONIA, FINLAND, FRANCE, GERMANY, GREECE, HUNGARY, IRELAND, ITALY, LATVIA, LITHUANIA, LUXEMBOURG,...
Page 9
This product is classified as an industrial monitoring and control instrument, and is not required to comply with the substance restrictions of the RoHS 3 Directives 2011 /65/EU and EU 2015/863 until July 22, 2021. This product does, however, comply with the RoHS 2 Directive 2011/65/EU. Korea Compliance Statement PRISM MPX2-25 Installation and Safety Instructions...
Page 10
Taiwan Compliance Statement Japan Compliance Statement Important Safety Information This manual contains information and warnings that must be followed by the user for safe operation and to keep the product in a safe condition. To safely perform service on this product, see the Service safety summary that follows the General safety summary. General Safety Summary Use the product only as specified.
Page 11
Be sure your work area meets applicable ergonomic standards. Consult with an ergonomics professional to avoid stress injuries. Use only the Telestream rackmount hardware specified for this product. Service Safety Summary The Service safety summary section contains additional information required to safely perform service on the product.
Page 12
Do not service alone: Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present. Disconnect power: To avoid electric shock, switch off the product power and disconnect the power cord from the mains power before removing any covers or panels, or opening the case for servicing.
Page 13
Damage to the instrument can occur if this instrument is powered on at temperatures outside the specified temperature range. CAUTION. To prevent static damage to the SFP module, if you remove the SFP module from the instrument, always transport the SFP module in a anti-static bag or container. PRISM MPX2-25 Installation and Safety Instructions xiii...
Video, Audio or Data Monitor PTP trend graphs to ensure proper IP system setup for robust sync system Telestream patented timing display showing the relative timing of the input signal and PTP reference that makes facility timing easy...
Page 15
Rails Installation Instructions Searching for documents The fastest way to find a document on the Telestream website is to go to http://www.telestream.net/video/resources.htm#Literature click on the product name PRISM and you’ll see a list of document choices. Conventions used in this manual These icons may be used throughout this manual.
For the rest of the instrument, use a 75% isopropyl alcohol solution as a cleaner and rinse with deionized water. Before using any other type of cleaner, consult your Telestream service center or representative.
Accessories Table 1: Standard and optional accessories Accessory Std. Opt. Part number Installation and Safety Instructions 071- 3739-00 √ Power cord See the section, International power cords. √ SFP and transceiver modules: SD/HD/3G Optical (1310 nm) SDI SFP transmitter module (to be MP-SFP Opt.
Page 19
When ordering the A99 option, it is the responsibility of the end user to ensure that a certified power cord, for the country or region it is installed, is used with this instrument. CAUTION. To reduce risk of fire and shock, use the certified power cord provided with the product. PRISM MPX2-25 Installation and Safety Instructions...
Operating requirements This section provides the environmental and power operating requirements for the instrument. See the PRISM Specifications and Performance Verification Technical Reference for additional information on product environmental and power specifications. Environmental operating requirements Check that the location of your installation has the proper operating environment as listed in Table 2. CAUTION.
Typically 10.21 kg (22.5 lb.), includes rackmount kit Equipment rack installation There is an optional Rackmount Slides and Rails Kit available for the PRISM MPX2-10 monitor (MPX2-10 RACK). The rackmount kit includes the Rackmount Slides and Rails Kit Installation Instructions document. PRISM MPX2-25 Installation and Safety Instructions...
Rear panel connectors Figure 1 shows the external connections to the rear panel of the instrument. A description of each connector is provided in the following table. See Front panel controls and connectors for information about the front panel connectors. Figure 1: PRISM MPX2-10 rear panel Item number (See Figure 1.)
Page 23
HDMI port. HDMI port output for an external monitor. The output video format is 1920×1080. When connecting to an external monitor, a monitor with a 1920×1080 capable display works best with the instrument. PRISM MPX2-25 Installation and Safety Instructions...
SFP module installation There are several types of optional SFP modules available. See Table 1 Standard and optional accessories. To install the SFP module, you will first need to remove the plug from the SFP connector. Insert the SFP module into the SFP connector as shown in Figure 2 (optical SFP module shown).
To minimize the risk of damage to the instrument, it is strongly recommended that the power cord be connected to the instrument before the power cord is connected to the AC power source. Figure 3: Connecting the power cord to the instrument PRISM MPX2-25 Installation and Safety Instructions...
Page 26
Power-on procedure 1. Apply power to the instrument. (See Power cord installation.) NOTE. If the PRISM monitor was previously powered off by a power interruption or by removing the power cord from the rear of the instrument, the instrument will power on when power is reapplied. 2.
When you use the PRESET and INPUT buttons, the associated menus appear on the display. The menus close after a short time-out period. Similarly, when you use the VOLUME or BALANCE control, the volume or balance slider and mute controls appear on the display and close after a short time-out period. PRISM MPX2-25 Installation and Safety Instructions...
Application tabs. Some applications have selectable tabs (highlighted readouts) you can use to display additional information. Application tile 4. Application tile 2. The application panels can be shown in four-tile mode or in full screen mode. PRISM MPX2-25 Installation and Safety Instructions...
How to select an input to monitor: 1. Press the INPUT button to prepare the instrument for an input selection. 2. Press the SELECTIONS numbered button corresponding to the input you want to monitor. PRISM MPX2-25 Installation and Safety Instructions...
Page 30
The terms "press and hold", “ tap”, “swipe”, and “pinch” apply to the touchscreen on the instrument. If you are using a mouse and keyboard you must “click and hold”, “click”, “scroll” and use the scroll wheel on the mouse. PRISM MPX2-25 Installation and Safety Instructions...
Page 31
1. On the PRISM monitor, open the Settings > Network page to view the Control IP Port address of the instrument to On your computer, enter the address http://xxx.xxx.xxx.xxx:6080/vnc.html which you are going to connect. into a web browser, where xxx.xxx.xxx.xxx is the IP address of the Control IP Port of the instrument. PRISM MPX2-25 Installation and Safety Instructions...
Page 32
2. A login web page is shown. 3. In the Control bar, click the Settings icon to open the Settings dialog. 4. In the Settings dialog, use the Scaling Mode drop-down list to select Local Scaling, and then click Apply. PRISM MPX2-25 Installation and Safety Instructions...
Page 33
You can use the WEB REMOTE tab of the PRISM Settings > Network menu to change the default password for the remote web connection. 7. The web browser connects to the instrument with the browser display appearing exactly like the display on the external monitor, but with a slower update. PRISM MPX2-25 Installation and Safety Instructions...
Need help?
Do you have a question about the PRISM MPX2-25 and is the answer not in the manual?
Questions and answers