Page 1
APCET Temperature Controller Specs Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC Temperature control range 45º to 95º F Separate Day & Night settings *photocell control Temperature accuracy +/- 5 ºF Temperature dead-band (hysteresis) 3 ºF Weight <...
Page 2
Basic Description The APCET is a temperature controller that can be used as a Cooling OR a Heating controller. Once the APCET is connected to a power source, and the cooling or heating device is connected to the APCET power outlet, the device connected will be automatically controlled by the settings on the APCET.
Page 3
Selecting Cooling or Heating Mode Before using the unit, the user must decide if they are using it for a Cooling or a Heating control. The 2 knobs on the unit are used to select the desired mode. To select Cooling: Connect the unit to power. Rotate both knobs fully COUNTER-clockwise.
Page 4
Q & A How can I tell if the photocell is working? There is a built-in 20 second time delay for the photocell to change status. A green LED on the top RIGHT edge of the unit that says “Daytime” will light up when the photocell is in Daytime mode.