Daystrom Heathkit IG-72 Assembly Manual page 19

Audio generator
Table of Contents

Advertisement

Paee
16
|z<@=El
(\ )
Arstaff the
five
lorot
s
on
the
shaJts of the panel controls vrith the pointers at the extreme
counterclockwise marking
on
the panel,
and
tighten the setscrews.
(
)
InstaU
the
3
watt
115
volt
candelabra lamp
and
the
6X4, 6AU6, and
6CL6 tubes in
their
proper sockets.
See
tr'igure
14,
(
)
Instau
the handle on the cabinet
with 10-24 screws.
(
)
Molmt
tfle
lour
rubber
feet
with
6-32
x
1/2"
screws,
#8
flat
washers,
#6
lockwashers, and 6-32 nuts as shown in Figure
16.
Figure
16
INITIAL
TEST AND
ADJUSTMENT
Plug
the Iine
cord
into a
105-125
volt
50-60
cycle
outlet.
Do
not
plug
into
an ouuet
of
higher
voltage
or
Iowerfrequency,
o,
a DC
outtet,
as an
incorrect
power source
will
damagethe
trans-
Turn powerswitch
on
andobserve tubes
and
pilot
tampas they
light up.
IJ
they donot Iight,
turn
power
off
and
investigate Iilament
circuit
\?iring.
Set
OSCILLATOR
and
METER controls
about
midway.
Set
precision
(0-100)
CYCLEswitchtol0 ormore
and
advance OUTPUT
control.
This
should show a reading on the
meter.
Calibrate the
meter.
NOTE: IJ in
the loLlowing
test
the OUTPUT
control
is teft
oIf or
fuUy
counterclockwise,
it will
be
severly damaged. Prcceed
as
Io[ows:
Turn both CYCLE switches
to
0.
Turn the OUTPUT control to maximum clockwise. Turn
the ATTENUATOR
to maximum
clockwise
(10
volt or
+20
db).
Connect a
wire
between
the red
output binding postand one of the
pilot light terminals
on
the meter
terminai
board.
Use the
terminal
that gives a meter indica-
tion.
Turn
the
METEF control to
produce a
meter
reading
of
6.3
volts
on
the
O-10 scaLe (a
Iit-
tle
over halJ-way
up
the
scale).
Now remove the
wire.
II
an accurate AC
voltmeter of
adequate
sensitivity
(at least
500 O
per
volt
on
the
10
volt
range
for
instance)
is available,
it
should be used in preference to the above
ptocedure.
In that case:
select
a suitable
frequency
(between 50 and 3000
cycles,
depending on the AC
meter
used)
with
the CYCLE
and
MULTIPLIER switches and connect
the
meter to
the output
oI the
generator.
Adiust
the
METER control to produce
equal readings on the two meter6.
Adjust the OSCILLATOR control
as
follow6:
No
connections to the output
terminats.
OUTPUT
control
at
maximum.
CYCLE switches and MULTIPLIER
to
10
cycles
or
more.
Turn
OSCIL-
LATOR
control
to
give just over
lull
scale reading
on
the
meter.
Select
various
frequencies
between 10 cycles
and
100
kc and
iI
the
output drops below
fuII scale, readjust
OSCILLATOR
control for
full
acale.
Do
not
adjust
OSCILLATOR
controt higherthan necessary as higher
than
nominaL
distortion wiII result.
This completes
the adiustment
oI
the
instrument. Install
the generator
in
the cabinet
anal
lasten
wlth the two
#6
sheet
metal screws
throwh
the
rear
of the cabinet into the chassis.
ro