Download Print this page

Makita SA7000C Technical Information page 6

Angle sander 180mm 7"
Hide thumbs Also See for SA7000C:

Advertisement

W
iring diagram
[2] Wiring of the Lead Wires of Pickup Coil
1) First, route the white lead wire of pickup coil under the rib.
And then hold both of the white and the black lead wires
with the lead wire holder. (Fig. 15)
2) When installing Handle (L) onto Motor housing, route the
two lead wires as illustrated in Fig. 16.
Fig. 15
Lead wire holder
Lead wire of
pickup coil
(black)
Lead wire of
pickup coil
(white)
[3] Wiring in Handle
Fig. 17
Before setting Switch in place, hold the three (or four) lead wires with the lead wire holders under switch as
illustrated below. When using Choke coil, place the lead wire d under other lead wire as illustrated below.
Lead wire holders
Noise suppressor*
Insulated connector*
(Use for connecting the
lead wire from Choke
coil with the lead wire
from Noise suppressor.)
Pickup coil
Rib
Note: The position of b and that of d are replaceable.
With Lead wire holder A, hold the lead wires that connect
Lead wire
Controller with Connector on Switch.
holder A
With Lead wire holder B, hold the other lead wires.
At this time, put the lead wire from Controller (blue or white)
Lead wire
and the lead wire from Choke coil (orange)* under the other
holder B
lead wires.
Switch
Insulated connector
Lead wire holder C
With Lead wire holder C, hold more
than one lead wire that is connected
with this insulated terminal.
Note: Some countries do not use the electrical parts with an asterisk.
Fig. 16
Rib
Handle (L)
a) Lead wire from Controller (blue or white)
b) Field lead wire (white)
c) Lead wire from Controller (red)
d) Lead wire from Choke coil (red)*
Rib Boss
Route lead wires between rib and boss
and between rib and wall of handle (L).
P 6 / 6
Motor housing
Pickup coil
Boss on Handle (L)
Speed adjust dial
Controller
Route the lead wires
that connect Controller
with Speed adjust dial
between these ribs, and
put them under the dial.

Advertisement