General Description; Ambient Temperature; Symbols Used In This Document - Grundfos LC-Ex4 Installation And Operating Instructions Manual

Table of Contents

Advertisement

English (GB) Installation and operating instructions
Original installation and operating instructions.
CONTENTS
1.

Symbols used in this document

2.

General description

3.
Application

3.1 Ambient temperature

4.
Electrical connection
4.1 Electrical data
4.2 Installation
5.
Maintenance
5.1 Replacement of parts
5.2 Product numbers
6.
Fault finding chart
7.
Disposal
Warning
Prior to installation, read these
installation and operating instructions.
Installation and operation must comply
with local regulations and accepted
codes of good practice.
1. Symbols used in this document
Warning
If these safety instructions are not
observed, it may result in personal
injury.
Warning
If these instructions are not observed,
it may lead to electric shock with
consequent risk of serious personal
injury or death.
Warning
These instructions must be observed
for explosion-proof pumps. It is
advisable also to follow these
instructions for standard pumps.
If these safety instructions are not
Caution
observed, it may result in malfunction
or damage to the equipment.
Notes or instructions that make the job
Note
easier and ensure safe operation.
2. General description
The Grundfos LC-Ex4 unit is an intrinsically safe
Zener barrier. The unit ensures that signals to and
Page
from the float switches never exceed a current or
voltage which may cause an explosion.
5
Warning
5
The unit has been certified under the
5
DEMKO 11 ATEX 1047766X and
5
complies with the standards
6
EN 60079-0:2009 and EN
6
60079-11:2007.
6
Safety class: II (1) G [Ex ia Ga] IIC.
6
3. Application
6
6
The LC-Ex4 unit is used together with the controllers
LC 108 and LCD 108 controlling pumps with float
7
switches installed in wastewater environments where
7
explosive gases may be present.
The unit is only suitable for operation with float
switches. The basic functions of the LC 108 and
LCD 108 remain unchanged.
3.1 Ambient temperature
Ambient temperature during storage and operation:
-25 °C ≤ Ta ≤ +50 °C.