EasyPro TM Series Instructions For Operation, Safety, Warranty page 2

High quality waterfall pumps

Advertisement

Specifi cations
Model
HP
Watts
TM9500
1
TM13500
1.5
Pump Performance Chart
Installation
Symbol and Meaning:
DANGER
Keep the pump equipment out of the reach of children! Warns that failure to
follow directions could cause serious risk/injury to individuals or objects.
WARNING
This sign warns the operator that the failure to follow an instruction may
damage the pump and/or the system.
Limitations:
This series of pumps are suitable to pump rain water and also can be used both for permanent and temporary installa-
tion. The pump can be placed in a sump pit, then can pump dirty water containing suspended solid particles up to
diameter.
WARNING: The pump cannot be used for sea water and fl ammable, corrosive, explosive or dangerous liquids.
Installation:
WARNING:
Do not work on pump until power is unplugged.
Do not cut off ground pin or use an adapter fi tting.
Do not use an extension cord
Must be used on a GFCI protected outlet
Do install the strainer prior to using if you want to let the pump run as a sump pump.
The pump power cord should be connected to a separately fused, grounded line with a minimum capacity of 15 amps. It
can be connected to non- fuse breaker at the recommended amps. Never touch the pump when it is plugged in.
1.
Before installing or servicing this pump, be certain pump power source is disconnected. Contact a qualifi ed li-
censed electrician for disconnecting electrical service prior to pump removal.
2.
Installation and electrical wiring must adhere to state and local codes and must be completed before priming
pump. Check appropriate community agencies, or contact local electrical and pump professionals.
3.
Call an electrician when in doubt. Pump should be connected to a separate 15 amp circuit breaker or 15 amp fuse
block. Note that, plugging into existing outlets may cause low voltage at motor, causing blown fuses, tripping of
motor overload or burned out motor.
4.
A permanent ground connection from pump to the grounding bar at the service panel is mandatory. For maximum
safety, connect pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the
pump's grounding wire.
5.
Voltage of power supply must match the voltage of the pump.
WARNING: Must be vented in accordance with local plumbing codes. EasyPro pumps are not designed for and
CANNOT be installed in locations classifi ed as hazardous.
Max. Amps
750
10.9
1125
12
Weight
Dimensions
52 lbs.
12" x 7.5" x 19.5"
58 lbs.
12" x 7.5" x 20"
Max. Head
Max. Flow
31'
9500 GPH
33'
13500 GPH
/
"
1