TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION ..........2 VACUUM PACKAGING GUIDELINES ..........3 PRODUCT COMPONENTS ..............5 FEATURES AND OPTIONS ..............7 BEFORE FIRST USE… ................9 Filling the Vacuum Pump ..............9 Draining the vacuum pump ............10 OPERATING INSTRUCTIONS ............12 MAINTENANCE ................
IMPORTANT SAFETY INFORMATION When using this electrical appliance, basic safety precautions should always be followed including: 1. Read and understand all instructions. 2. Operate the appliance indoors only on a dry, stable, hard surface. 3. Do not use the appliance near a heat source, on a hot surface, or in wet conditions.
VACUUM PACKAGING GUIDELINES • Follow all food safety regulations as outlined by the FDA at www.FDA.gov. • Vacuum packaging is NOT a substitute for canning. • Vacuum packaging is NOT a substitute for refrigeration or freezing. • Vacuum packaging cannot reverse the deterioration of foods.
Page 5
Food Storage and Safety Information Typical Vacuum Storage Foods Storage Packaging Meat 6 months 15-20 months Fish, Seafood 6 months 10-12 months Frozen Dried fruit, Coffee 6-9 months 18-24 months beans Meat 2-3 days 12-13 days Fish, Seafood 2-3 days 6-8 days Cooked 2-3 days...
1. Power Switch After the machine is plugged in, the LED display will show “OFF” and the C25v will be in Power Saving mode. Turn the Power Switch to “On” and the LED display will show “CLO” if the lid is closed or “ON”...
Page 9
Press the button “∧” or “∨” to increase or decrease each setting. Note: There is no Gas option on the C25v at this time. 4. Vacuum Gauge Shows the vacuum level inside the vacuum chamber.
BEFORE FIRST USE… Filling the Vacuum Pump before the first use Filling the oil pump is required , when the oil level is below the minimum oil level, or if performance is seriously reduced. The oil needs to be replaced after 25 hours of the first use and then after every 60 hours of use.
Draining the vacuum pump After the first 25 hours of operation and at regular intervals thereafter or when a noticeable lack of vacuum occurs, drain and replace the oil. Steps for draining: Remove the oil inspection window. Place a suitable vessel under the oil drain before beginning this procedure.
Page 12
Screw oil pump cap for oil filling Max level port Min level Oil inspection window Screw cap for oil drain port...
OPERATING INSTRUCTIONS Read all instructions before operating the C25v. 1. Select Vacuum Pouch Select the proper size vacuum pouch. Allow a minimum of 1” to 2” of extra headspace at the top of the pouch to ensure a quality, air-tight seal.
Page 14
Sealing Time: With the lid open, press the “Set” button until the indicator light next to Seal Time is on. Press “∧” or “∨“ button to increase or decrease seal time. For the initial test, set seal time to 5 seconds. Adjust the time accordingly to achieve a perfect seal;...
Page 15
If the seal is “white or milky”, decrease the seal time by 1 second. Restoring defaults With the C25v in Power Saving mode (LED displays “OFF”), press “Set” + ”^” buttons simultaneously for 3 seconds. When the machine beeps and displays rS, the default settings will be...
MAINTENANCE 1. Always unplug the machine before cleaning. 2. Do not immerse the machine or electrical cord in water or any other liquid. 3. Do not use abrasive cleansers or scouring pads to clean the machine to avoid scratching the surface. 4.
TROUBLESHOOTING Under the proper circumstances, your vacuum sealer will provide years of problem-free use. Under certain circumstances, issues may arise. Please consult the troubleshooting information and error codes below prior to contacting technical support. Fails to operate • Make sure the machine is plugged into an electrical outlet. •...
ERROR CODES AND TROUBLESHOOTING Error code Causes Troubleshooting 1. Ensure the lid is closed tight. 2. Check if the gasket is When the installed in right machine is position. vacuuming for 3. Check if the pump is some time, the working or not.
• Full refunds can only be provided within 30 days of purchase directly from Vesta Precision. Devices purchased through resellers, retail partners, or other websites are not eligible for a return and full refund. Please consult their return policies for more information.
Retail exchanges can only be provided within 30 days of purchase directly from Vesta Precision. Products purchased through resellers, retail partners, or other websites are not eligible for a retail exchange. Please consult their exchange policies for more information. We cannot provide a retail exchange for any damaged devices not covered under our limited warranty.
Damaged and Defective Items If you received a damaged or defective product, notify us immediately for assistance via phone, email, or web support. Please note that if we do not have an exact replacement for your unit, we will replace it with a similar unit of equal or greater value.
Page 23
Precision Appliance Technology, Inc. Questions or Problems? Contact support via Website: www.vestaprecision.com Email: support@vestaprecision.com Phone: +18335045101 (US) +442039363041 (EU)
Need help?
Do you have a question about the C25v and is the answer not in the manual?