UNDERSTANDING THE CONTROL BOARD

CONTROL PANEL
Turning the heater OFF/ON, as well as adjustments for the fuel feed
rate and room fan speed are performed by pressing the appropriate
button(s) on the control panel which is located on the lower left-hand
side of your Hearth Focus heater.
This unit can be changed between an automatic operation or a
manual operation. The controller comes default in the automatic
mode.
Pressing the "ON" button on the control panel will begin the start-
up sequence for the heater. Fuel will begin to feed through the auger
feed system after 3 minutes. Pressing and holding the "ON" button
will rotate the auger continuosly until button is released, which feeds
additional fuel.
Heat
Room
Draft
Aux.
Pressing the "OFF" button on the control panel will cause the heater
Range
Fan
Fan
to enter its shut-down sequence. The fuel feed system will stop
pulling fuel from the hopper and, once the fire goes out and the heater
cools down, the blowers will stop running.
Auto
Pressing the "Heat Range" arrows, up or down, will adjust the
amount of fuel being delivered to the burnpot.
The draft fan (exhaust) will come on as soon as the "ON" button is
pressed. The fan will automatically adjust its speed in accordance
Manual
to the heat range setting. However, this speed can be manually
operated by pressing the "Draft Fan" arrows up or down. "Draft
Fan" when pressed, the display will show "Df-A", which is automatic.
Press the arrows again to adjust fan speed. When the heater is in
the manual mode, the optional thermostat will not properly control
the unit. When adjusting the Draft Fan setting, try only 1 setting
above or below the heat setting.
The room fan will come on once the unit has reached operating temperature (110°F). By pressing the "Room
Fan" buttons, the display will show "Rf-A" which is automatic or "Rf-1" through "Rf-9" for manual settings. In
auto mode, the room fan's speed will automatically be adjusted in accordance with the heat range setting. By
pressing the "Room Fan" up arrow, you can adjust the fan speed setting up to "Rf-9". The fan speed can be
adjusted to a higher setting than the heat setting but not lower.
The "Aux" button is for Agitator operation. When the unit is "OFF", pressing the "Aux" arrows will rotate the
agitator for easy removal for cleaning. The agitator, when in Automatic mode, will operate at set intervals.
However, these can be changed by pressing the arrows on the "Aux" button. The agitator can be adjusted
from 0 to 9, setting "0" is off and setting "9" is high.
The "Auger Delay" button can be used to pause rotation of the Auger and Agitator for approx. 1 minute. This
can be cancelled by pressing the "ON" button.
The "Mode" button is used to switch between manual and automatic mode. When in auto mode, the fan,
auger, and agitator will operate at preset intervals unless changed manually using the buttons mentioned
above. When in manual mode, the draft fan (exhuast) will operate at full speed (100%), so the air must be
controled with the damper just below the viewing door.
During normal operation, the unit is constantly monitored for problems. In the event of an error condition, the
unit will stop and an error will be displayed. See the list of error codes found at the end of this manual.