Onyx MATE-2405 Manual

24”/22” lcd with led backlight intel 8th/9th core processor medical aio

Advertisement

Quick Links

M e d i c a l AI O
M A T E - 2 4 0 5 / 2 2 0 5
MATE-2405/2205
24"/22" LCD with LED Backlight
Intel
®
8
th
/9
th
Core
TM
Processor
Medical AIO
MATE-2405/MATE-2205 Manual 1st Ed
Dec. 2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MATE-2405 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Onyx MATE-2405

  • Page 1 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 MATE-2405/2205 24”/22” LCD with LED Backlight Intel ® Core Processor Medical AIO MATE-2405/MATE-2205 Manual 1st Ed Dec. 2019...
  • Page 2 The material in this document is for product information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, ONYX Healthcare Inc., assumes no liabilities resulting from errors or...
  • Page 3 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Acknowledgments Intel ® Core is registered trademarks of Intel ® Corporation.  Microsoft Windows is a registered trademark of Microsoft ®...
  • Page 4 M A T E - 2 4 0 5 / 2 2 0 5 Packing List Before you begin installing your Medical Station, please make sure that the following items have been shipped: MATE-2405/2205 Smart View Medical Station  Medical Power Adapter 120W/12Vdc ...
  • Page 5 2F, No.135, Lane 235, Pao-Chiao Rd., Hsin-Tien City, Taipei 231, Taiwan, R.O.C. TEL: +886-2-8919-2188 FAX: +886-2-8919-1699 E-mail: sales@onyx-healthcare.com http://www.onyx-healthcare.com Worldwide Offices: Onyx Healthcare, USA Inc. 324W. Blueridge Ave., Orange,, CA 92865, USA Tel : +1-714-792-0774 Fax: +1-714-792-0481 Email: usasales@onyx-healthcare.com Onyx Healthcare EUROPE B.V.
  • Page 6 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Onyx Healthcare (Shanghai) INC. 20F, unit D, GEM Building, No. 487 Tianlin Road, Shanghai, China Tel: +86-021-64956588...
  • Page 7 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Safety & Warranty 1. Read these safety instructions carefully. 2. Keep this user's manual for later reference. 3.
  • Page 8 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 13. Never pour any liquid into an opening. This could cause fire or electrical shock. 14. Never open the equipment. For safety reasons, only qualified service personnel should open the equipment.
  • Page 9 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 16. If any of the following situations arises, get the equipment checked by service personnel: a. The power cord or plug is damaged. b.
  • Page 10 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Classification 1. Degree of production against electric shock: not classified 2. Degree of protection against the ingress of water: IPX0 3.
  • Page 11 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 This device complies with Part 18 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired...
  • Page 12 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 UL Module Description MATE-2405/2205 modules are developed to suitable for the Classification Mark requirement...
  • Page 13 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Safety Symbol Description The following safety symbols are the further explanations for your reference. Medical equipment with respect to electric shock, fire and mechanical hazards only in accordance with ANSI/AAMI ES 60601-1 (2005) + AMD 1 (2012) AND...
  • Page 14: Table Of Contents

    1.3 Specification ..............1-4 1.4 Dimension ............... 1-8 Chapter 2 Hardware Installation 2.1 Safety Precautions ............2-2 2.2 Quick Tour of the MATE-2405/2205 ......2-3 2.3 Turn On and Boot up into Windows…………………….2-7 2.4 Turn off……………………………………………………….2-7 Chapter 3 Driver Installation Appendix A Miscellanea A.1 General Cleaning Tips ..........
  • Page 15: Chapter 1 General Information

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Chapter General Information...
  • Page 16: Introduction

    MATE-2405/2205 includes all the features of a powerful computer into a slim and attractive chassis. MATE-2405 has a 24” 250 nits TFT display with 1920 x 1080 resolution. MATE-2205 has a 22” 250 nits TFT display with 1920 x 1080 resolution. Integrating with high brightness LCD is easier to analyze DICOM image.
  • Page 17 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 including Surgical, Radiology, PACS (Picture Archiving Communication Systems), LIS (Lab Information Systems) and Electronic Medical Record. MATE-2405/2205 are definitely your perfect choices.
  • Page 18: Feature

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 1.2 Feature 24”/22” Intel Core Processor ®  Supports Dual Channel DDR4 SODIMM up to 32GB  Supports One PCI Express Expansion(optional) ...
  • Page 19: Specification

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 1.3 Specification Hardware Specifications MATE-2405: 24” 1920x1080 LCD Display MATE-2205: 22” 1920x1080 LCD ® Intel Core i7-9700TE Processor ®...
  • Page 20 30,000 Hrs Note: All ONYX LCD products are manufactured with High precision technology. However, there are a small number of defective pixels in all LCD panels that are not able to change color. This is a normal occurrence for all LCD displays from all manufacturers and should not be noticeable or objectionable under normal operation.
  • Page 21 Mounting / Holder VESA 75/100mm, Screw type:M4*8mm Construction 3mm ABS + PC TYPE Plastic housing Dimension (WxHxD) MATE-2405: 600mmx 415mm x 65 mm MATE-2205: 546mm x 351mm x 66mm Net Weight MATE-2405: 21.4 lb (9.7 Kg) MATE-2205: 17.6 lb (8.0 kg)
  • Page 22 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Environmental Specifications Operating Temperature 0˚C to 35˚C (32˚F ~95˚F) Storage Temperature -20˚C to 60˚C (-4˚F ~140˚F) Storage Humidity 10% to 90%@ 40˚C, non-condensing Vibration 0.5G / 5 ~ 500Hz (Random) / operation...
  • Page 23: Dimension

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 1.4 Dimension MATE-2405...
  • Page 24 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 MATE-2205...
  • Page 25: Chapter 2 Hardware Installation

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Chapter Hardware Installation...
  • Page 26: Safety Precautions

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 2.1 Safety Precautions Always completely disconnect the power cord from your board whenever you are working on it.
  • Page 27: Quick Tour Of The Mate-2405/2205

    M A T E - 2 4 0 5 / 2 2 0 5 2.2 Quick Tour of the MATE-2405/2205 There are 8 control buttons in the front side of MATE-2405/2205. Please refer to table 2.1 for the function of each button.
  • Page 28 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Control Button Function Press 2 seconds to turn on the power ● Blue : working state ● Orange : sleep state Increase LCD brightness (Blue) Decrease LCD brightness (Blue) Increase speaker volume (Blue)
  • Page 29 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 The sunken I/O section is at the bottom, as shown in Picture 2-2. MATE-2405 MATE-2205 Picture 2.2: Rear view of the MATE-2405/2205 Series...
  • Page 30 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 When you turn MATE-2405/2205 around, two USB 2.0 ports and on the left side as shown in Picture 2-3.
  • Page 31: Turn On And Boot Up Into Windows

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 2.3 Turn On and Boot up into Windows OS This section is for Windows operating system only. If you are installing a different operating system, please contact your vendor for installation details.
  • Page 32: Chapter 3 Driver Installation

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Chapter Driver Installation...
  • Page 33 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 There are several installation ways depending on the driver package under different Operating Systems. Please follow the sequence below to install the drivers: For Windows 10 Step 1 –...
  • Page 34: Appendix A Miscellanea

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 Appendix Miscellanea...
  • Page 35: General Cleaning Tips

    Some individuals may be allergic to the ingredients. Try not to put any food, drink or cigarette around the computer. ONYX Healthcare Inc. has tested and verified these cleaning disinfectants, CIDEX, Viraguard, Control III Disinfectant Germicide, Caviwipes, Dispatch Disinfectant Cleaner CLH69101, Puregreen 24 Disinfectant, can be used with the MATE-2405/MATE-2205.
  • Page 36: Cleaning Tools

    M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5 A.2 Cleaning Tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers and peripherals.
  • Page 37 M e d i c a l AI O M A T E - 2 4 0 5 / 2 2 0 5  Foam swabs - Whenever possible it is better to use lint free swabs such as foam swabs. Note: We strongly recommended that you should shut down the system before you start to clean any single components.
  • Page 38: Scrap Computer Recycling

    For the computers that are no longer useful or work well, please contact with worldwide distributors for recycling. The worldwide distributors show on the following website: http://www.onyx-healthcare.com.tw/Contact.php Note: Follow the national requirement to dispose unit...

This manual is also suitable for:

Mate-2205

Table of Contents