CAS Healthcare Solution NB-152U Owner's Manual
CAS Healthcare Solution NB-152U Owner's Manual

CAS Healthcare Solution NB-152U Owner's Manual

Ultrasonic nebulizer
Table of Contents

Advertisement

Ultrasonic Nebulizer
초음파 흡입기
NB-152U
제품의 색상은 실제와 다를 수 있습니다.

Advertisement

Table of Contents
loading

Summary of Contents for CAS Healthcare Solution NB-152U

  • Page 1 Ultrasonic Nebulizer 초음파 흡입기 NB-152U 제품의 색상은 실제와 다를 수 있습니다.
  • Page 3: Table Of Contents

    구매해주셔서 감사합니다. 제품의 올바른 사용과 유지를 위해서 반드시 제품을 사용하기 앞서 본 사용설명서를 잘 읽어주시기 바랍니다. 차 례 부품 및 구성요소 ..........................기호 ................................일반 ................................주요 안전지침 - 준비 ................................- 작동 ................................- 청소 ................................- 보관 ................................작동순서...
  • Page 4: 부품 및 구성요소

    부품 및 구성요소 본체 분무칸 저수조 커버 수위 표시등 공기 흐름 조절 노브 전원 표시등 O/ I 및 분무 속도 조절 노브 분무칸 분무칸 커버 저수조 커버 분무칸 중간 셸 약물 컵 분무칸 하단 셸 밀봉 링...
  • Page 5 기호 기호 의미 제조업체 유럽공동체 공인 대표 지침 2002/96/EC을 준수하는 전기/전자기기임을 나타내는 기호. 사용한 장비, 부품 및 배터리는 올바른 폐기물 처리 방식에 따라 처리해야 합니다. 폐기물 처리에 관한 해당 지역의 조례 및 규정에 따라 처리하시기 바랍니다. EC 지침 93/42/EEC의 준수를 나타내는 CE 라벨 건조한...
  • Page 6: 주요 안전지침

    일반 본 초음파 흡입기(이하: 장치)는 미세하고 조밀한 에어로졸 형태의 액체 약물을 주입하는 의료기기입니다. 분무기의 기체 흐름이 환자의 흡수를 개선할 수 있도록 기관지와 폐를 통해 신체에 젖은 에어로졸을 전달합니다. 주요 안전지침 사용 전 모든 지침을 숙독하시기 바랍니다! 준비 •본 설명서에 명시된 용도로만 사용하며, 다른 용도로는 사용하지 않도록 합니다. •반드시...
  • Page 7 작동 •어린이 또는 지체 부자유자가 장치를 사용하는 경우 면밀한 감독이 필요합니다. •이상이 발생한 경우 그 즉시 장비 사용을 중단합니다. •눈 가까이에서 약물이 분무되지 않도록 합니다. •인화성 가스를 사용하는 장소에서는 장치를 사용하지 않도록 합니다. •물 탱크 또는 약물 컵이 빈 상태에서는 절대 장치를 작동시키지 마십시오. •변환기가...
  • Page 8: 저수조 채우기

    작동 순서 •장치를 처음 사용하거나 장기간 보관했던 사용하는 경우, 11페이지에 설명된대로 필요한 모든 부분을 반드시 청소하고 소독해야 합니다. •충진 및 사용 전 제품의 플러그를 뽑고, 하단의 스위치를 끄십시오. 저수조 채우기 A. 그림 1과 같이 저수조커버를 꺼냅니다(분무칸 전체를 들어낼 수도 있습니다). 그림...
  • Page 9: 외부 전원 연결

    약물 주입구 그림 3 그림 4 약물 컵 밀봉 링 그림 5 그림 6 주의 •분무 속도에 영향을 미치게 되니 12ml 이상 채우지 않도록 주의합니다. •의사의 지시가 있는 경우에 한해 약물을 사용하십시오. 외부 전원 연결 AC 콘센트에 전원 코드를 꼽습니다. 전원...
  • Page 10: 공기흐름 속도 조절

    공기 흐름 조절 '최소'와 '최대' 사이의 범위에서 '공기 흐름 조절 노브'를 돌려 원하는 공기 흐름 속도를 맞춥니다. 마스크 (마우스피스) 착용 및 치료 시작 그림 7과 그림 8처럼 분무칸에 연장 튜브와 마스크 (또는 마우스피스)를 조립해 착용한 후 치료를 시작합니다. 그림 7 그림...
  • Page 11: 잔여약물 및 물 처리

    잔여 약물 및 물 처리 A. 분무칸과 함께 저수조 커버를 엽니다. B. 분무칸 커버를 제거합니다. C. 약물 컵에 남아 있는 약물을 비웁니다. D. 저수조의 물을 빼냅니다. 주의 •사용 직후 물은 뜨거우니 닿지 않도록 조심하십시오. 청소 A. 마스크, 마우스피스, 연장 튜브, 저수조 커버, 분무칸, 약물 겁: 중성세제나...
  • Page 12: 문제해결

    사양 제품명 초음파 흡입기 (NB-152U) 전원 220Vac 60Hz, 230Vac 50Hz 전력소비량 약 45VA 안전등급 B형 장치. 등급 II 초음파 주파수 1.7MHz ±10% 최대 분무 속도 ≤1.5ml/min 입자 크기 ≤5μm 약물 컵 용량 12 ml 소음 수준 ≤55DB 작동 온도 및 습도 +10°C~+40°C, 75% 이하...
  • Page 13: 보증서

    보증서 •CAS는 구입 일자로부터 1년 간 정상적인 사용 조건에서 제품의 소재 및 만듦새에 결함이 없음을 보증합니다. •다음을 포함한 남용이나 잘못된 사용에 따른 피해는 보증에서 제외됩니다: - 무단 수리 또는 개조에 의한 고장; - 충격 또는 운반 중 낙하로 인한 파손;...
  • Page 14 Thank you for your purchase. For the proper using & maintaining the scale please read this instruction completely before operating. TABLE OF CONTENT PARTS AND COMPONENTS .................. SYMBOLS ............................GENERAL ............................IMPORTANT SAFEGUARDS PREPARATION ............................ OPERATION ............................CLEANING ............................STORAGE .............................
  • Page 15: Parts And Components

    PARTS AND COMPONENTS Main Body Nebulizing Compartment Water reservoir Cover Water Level Alarm Light Air Flow Adjusting Knob Power Indicator O/l and Nebulizing Rate Adjusting Knob Nebulizing Compartment Cover of Nebulizing Compartment Water Reservoir Cover Middle Shell of Nebulizing Compartment Medicine Cup Bottom Shell of Nebulizing Compartment...
  • Page 16: Symbols

    SYMBOLS Symbols Meaning Manufacturer Authorized Representative in the European community Symbol for the marking of electrical and electronics devices according to Directive 2002/96/EC. The device, accessories and the packaging have to be disposed of waste correctly at the end of the usage. Please follow Local Ordinances or Regulations for disposal CE marking in conformity with EC directive 93/42/EEC Keep dry...
  • Page 17: General

    GENERAL This desk type ultrasonic nebulizer (Hereinafter: equipment) is a medical device that delivers liquid medication in the form of fine, dense aerosol. The nebulizer gas flow transports the wet aerosol to the body through windpipe and lung so as to be better absorbed by the patient. IMPORTANT SAFEGUARDS Read all Instructions carefully before use! PREPARATION...
  • Page 18: Operation

    OPERATION •Close supervision is required when this equipment is used by children or invalids. •Stop using the equipment immediately if any abnormality occurs. •Keep your eyes away from the output of medication mist. •Do not use the equipment where flammable gas is being used. •Never operate the equipment with empty water tank or empty medication cup.
  • Page 19: Operation Procedure

    OPERATION PROCEDURE •To use the equipment for the first time, or after storing it for an extended period, be sure to clean and sterilize all necessary parts as described on page 22. •Always unplug this product and turn off the switch at bottom before filling and after use.
  • Page 20: Connect External Power

    Add medicine in Fig. 3 Fig. 4 Medicine Cup Seal Ring Fig. 5 Fig. 6 Caution •Do not fill more than 12ml, otherwise the nebulizing rate will be affected. •Use medications only under instructions of your physician. CONNECT EXTERNAL POWER Plug the power cord into an AC outlet.
  • Page 21: Adjust The Air Flow Rate

    ADJUST THE AIR FLOW RATE Turn the 'Air Flow Adjusting Knob' in the range between MIN and MAX to get your favorite air flow rate. ASSEBLE THE MASK (OR MOUTHPIECE) AND BEGIN TREATMENT Assemble the extension tube and mask (or mouthpiece) to the nebulizing compartment as Fig.
  • Page 22: Dispose Excess Medication And Water

    DISPOSE EXCESS MEDICATION AND WATER A. Take out the cover of water reservoir together with the nebulizing compartment. B. Remove the cover of the nebulizing compartment. C. Pour remaining medication out of medicine cup. D. Drain water from the water reservoir. Caution •Do not touch water, it is hot after use.
  • Page 23: Specifications

    SPECIFICATIONS Product Name Ultrasonic Nebulizer (NB-152U) Power 220Vac 60Hz, 230Vac 50Hz Power consumption Approx. 45VA Safety classification Type B apparatus. Class II Ultrasonic frequency 1.7MHz ±10% Max. nebulizing rate ≤1.5ml/min Particle size ≤ 5μm Medication cup capacity 12 ml Noise Level ≤55DB Operation temperature and humidity °C to...
  • Page 24: Warranty

    WARRANTY • CAS warrants its products free of defects in materials and workmanship in normal use for a period of ONE years from the date of retail purchase. • This warranty does NOT cover damages caused by misuse or abuse, including but not limited to: - Failure caused by unauthorized repairs or modifications;...
  • Page 25 MEMO...
  • Page 26 MEMO...