Clearfield YOURx Installation Manual

Clearfield YOURx Installation Manual

Multi-purpose terminal

Advertisement

Quick Links

YOURx Multi-Purpose Terminal
Installation Manual
______________________________________________________
Manual 021023 REV A - Jan 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YOURx and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Clearfield YOURx

  • Page 1 YOURx Multi-Purpose Terminal Installation Manual ______________________________________________________ Manual 021023 REV A - Jan 2020...
  • Page 2: Table Of Contents

    YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Table of Contents Application Description Technical Specifications Parts Tools Needed Configurations Deployment/Mounting Accessing the Terminal Capacity Splicing in the Multi-Purpose Terminal Mid-Spanning Buffer Tubes Splicing Pre-Connectorized Fiber Pigtails Splicing Clearfield’s FLATdrop Splicing in MOCs with Drops...
  • Page 3: Application

    0.7” (17.78mm). The terminal includes eight individual sealed distribution drops with remov- able tabs - all air and water-tight via YOURx FlexPort technology. The snap-in splice chip will support 12 loose tube splices or 3 mass fusion (36 fibers) splices, with the ability to store up to 8 feet per buffer tube.
  • Page 4: Parts

    YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Front View Parts 1. Terminal Cover 2. Terminal Bulkhead 3. Terminal Faceplate 4. Terminal Collar 5. Terminal Seal 6. Splice Chip 7. Splice Tray Cover 8. Adapter Plate 9. Strength Member Clamp 10. Gasket Plate 11.
  • Page 5 YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Back View Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net Manual 021023 REV A - Jan 2020...
  • Page 6: Configurations

    YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Configurations Option 1: Patch Option 2: Dead Only Stubbed End Splice (In Version Terminal Splicing) Option 3: Mid Span Option 4: Plug and Option 5: Plug (In Terminal Play (MPO Feed) and Play (Optical...
  • Page 7: Deployment/Mounting

    MPT to the mounting bracket with the 4 provided screws in the holes at the base of the terminal. Note: Clearfield recommends to orient the MPT mounting bracket with the 4 MPT mounting holes on the bottom of the bracket.
  • Page 8 YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Aerial Mounting Using the hardware provided, secure the adjustable aerial mounting brackets to the base MPT mounting bracket. The 3 slotted holes on each aerial mounting bracket will allow for a wide range of heights.
  • Page 9: Accessing The Terminal

    YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Accessing the Terminal In order to access the internals of the MPT, you must remove the collar and pull off the lid. Loosen the bolt holding the collar closed with a can wrench. Remove the collar and pull off the lid.
  • Page 10: Capacity

    _________________________________________________________ Capacity Slack Storage The YOURx Multi-Purpose Terminal is recommended for use with a max cable OD of 0.7 inches, with a possibility to midspan. The terminal is capable of storing up to 8 feet of buffer tuber depending on cable size.
  • Page 11 YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Adapter Plate Capacity and Configuration 8 SC Adapters 12 LC Adapters Adapter Plate Port Assignment *Up to 16 9 10 11 12 13 14 15 16 Top Row ports in certain configurations Bottom Row...
  • Page 12: Splicing In The Multi-Purpose Terminal

    Installation Manual _________________________________________________________ Splicing in the Multi-Purpose Terminal Prep your cable. Clearfield recommends opening no more than 8 ft (96”) of cable. Cut the strength members to roughly 5 inches in length. Place the hose clamps through the clamp locations on the terminal bulkhead.
  • Page 13 Route the fibers to be spliced (keeping others stored) and bring them into the splice chip. Trim fibers to length at the center of the splice chip. Note: Clearfield recommends at least 1.5 laps of slack stored in the splice tray. Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net...
  • Page 14: Mid-Spanning Buffer Tubes

    YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Mid-Spanning Buffer Tubes The following are instructions for mid- spanning a single buffer tube inside the MPT, and expressing the remaining fibers that aren’t spliced. Prior to storing the remaining buffer tubes in the back of the MPT, bring one side of the buffer tube to be mid-spanned through the opening on the side of the bulkhead.
  • Page 15 YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ With grommet tape, felt tape, or your local practice, protect the buffer tube by wrap- ping the material around the buffer tubes approximately 1/8” before the openings. Note: If using grommet tape, it is recom- mended to wrap buffer tube by folding tape over and then trimming.
  • Page 16: Splicing Pre-Connectorized Fiber Pigtails

    YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Splicing Pre-Connectorized Fiber Pigtails Locate the fiber assembly that was ordered for the terminal. Remove the twist ties from the fibers, and save both halves for later. Note: Fiber test record will be included. Place onto splice tray cover for future use.
  • Page 17 YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Install the adapters into the adapter plate. Inspect and clean the fiber endfaces and connect them into the back side of the adapters. Note: The underside of the back half of the adapter plate will have a metal clip.
  • Page 18: Splicing Clearfield's Flatdrop

    Splicing Clearfield’s FLATdrop After opening and tying the buffer tube into the splice tray on the desired side (Clearfield recommends opening a minimum of 30 inches of buffer tube) store the bare 250 micron fiber in the entire splice tray. This will allow for subsequent users to have easier access to the fibers when splicing additional drops at a later time.
  • Page 19 YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Bring the buffer tubes to the opposite side of the MPT bulkhead that the original buffer tube is secured to. You will secure the buffer tubes down at this location. Mark the length to reach the tie-down location on each buffer tube, and open the tubes 1/2 inch after that to expose the 900 micron fibers.
  • Page 20: Splicing In Mocs With Drops

    YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Splicing in MOCs with Drops MOC configurations of the Multi-Purpose Terminal will come with the MOC pre-installed and the distribution leg connectors loaded into the adapter plate. Simply splice in the feeder tail or connect the feed drop as shown in the splicing and drop sections of this manual.
  • Page 21: Grounding

    YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Grounding To ground the terminal, a ground stud will be threaded into one of the holes used to secure the gasket plate onto the base of the MPT. Insert the ground stud into the hole and hand tighten.
  • Page 22 YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Reinsert the ground stud and screw it through the base of the MPT until about 1” of the stud is on the inside of the terminal. Remove the two nuts from the back of the stud used to screw it in to place.
  • Page 23: Cable Sealing

    YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Cable Sealing Midspan On a clean and dry surface, cut the gasket at the “V” notch on each side of the gasket. Cut from the center opening down the side using a clean, sharp, and thin blade.
  • Page 24 YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Place the clear film cover over the cables and on top of the gasket. Press down on the film cover to further seat the gasket into the opening and around the cables. Take the two halves of the gasket cover plate and put them around your cables.
  • Page 25 YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Small Cables/FLATdrop and Single Cable Entrance For small cables or cable dead-ends where both sides of the entrance wont be used, make use of the provided adapter(s). If only one side of the cable entrance is used, insert an adapter into the unused gasket hole to seal it.
  • Page 26: Pre-Connectorized Drop Installation

    YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Pre-Connectorized Drop Installation Clearfield’s pre-connectorized drop choices allow for easy plug and play connectivity. Note: Can hard splice FLATdrops, see page 18. Microduct with Pushable Fiber FLATdrop with Flex Connector Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • techsupport@clfd.net...
  • Page 27: Microduct

    YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Opening the FlexPort To utilize a FlexPort, snap off the tab of the desired FlexPort with a pair of pliers, and de-burr the port to smooth out the edges. Microduct Using 14/10 microduct, ensure that the end of the microduct is a clean cut and de-burr the duct for a smooth transition into the terminal.
  • Page 28: Flatdrop

    YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Inspect and clean the connector, then make a direct connection to the assigned port. Note: You can NOT store FieldShield slack in this terminal. FLATdrop DO NOT assemble the connector until the fiber is through the FlexPort and inside the terminal.
  • Page 29 YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ If using a factory installed connector, assemble the outer housing of the connector as directed by the instructions provided with the connector housing. If using a field installed FlexConnector for custom drop lengths, refer to the instructions provided with the Field Installable FlexConnector kit.
  • Page 30: Installing Duplex Lc Pre-Connectorized Drops

    YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Installing Duplex LC Pre-Connectorized Drops Begin by pushing one of the connectorized fibers through the FlexPort. Once the first fiber is through the FlexPort, bring the second fiber through the port. Pull the Fibers Completely into the terminal.
  • Page 31: Connector Cleaning Procedure

    Inspect Then Connect These are Clearfield recommended products/applications. Use the product you feel will complete your cleaning procedures. Create a “best practice” for your company and follow those procedures.
  • Page 32 YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ Cleaning the Ferrule • Lightly moisten the fiber optic swab (2.5mm/38542F or 1.25mm/38040) by spotting a small amount (about 1”) of Electro-Wash PX or Electro-Wash MX pen onto the QbE. Hold the swab, 1 side down to the wetted area and hold for a count of 1-2-3-4-5.
  • Page 33 YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Cleaning an MPO/MTP Connector Male Connector • Use of Chemtronics MTP Connector Cleaning Swabs (CC505F) is rec- ommended. Even after cleaning with a probe cleaner, you should always clean the pins with this (or an equivalent) type swab. Cleans ALL MTP/ MPO connector end faces.
  • Page 34 YOURx Multi-Purpose Terminal Installation Manual _________________________________________________________ • Use the hole on end of pad to clean one alignment pin, then press the end of the swab into the other pin to clean. • Check your work with a fiber scope. This can take several attempts to get the endface clean.
  • Page 35 YOURx Multi-Purpose Terminal Installation Manual __________________________________________________________ Cleaning Using a Probe-Style Cleaning Tool • The probe style cleaning tools are capable of cleaning a connector end face separately or through the adapter. • Slightly engage probe by pulling back but do not allow to click. Lightly “spot” a QbE-2 wipe on the platen with Elec- tro-Wash PX Fiber Optic Cleaner, this will help alleviate “over saturation”...
  • Page 36: Standard Warranty

    Clearfield shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus- tomer’s site, freight prepaid Note: If the Product is not found to be defective by Clearfield, the product will be returned to the Customer and the customer billed for freight in both directions.
  • Page 37: Proprietary Notice

    __________________________________________________________ Proprietary Notice Information contained in this document is copyrighted by Clearfield, Inc. and may not be duplicated in full or part by any person without prior written approval of Clearfield, Inc. Its purpose is to provide the user with adequately detailed documentation to efficiently install the equipment supplied. Every effort has been made to keep the information contained in this document current and accurate as of the date of publication or revision.