USING AND KEEPING THE USE AND MAINTENANCE MANUAL ... 4 COMPOSITION OF THE MANUAL ... 4 GUARANTEE ... 4 PRODUCT RESPONSIBILITY ... 4 WARNING SIGNS IN THE MANUAL AND ON THE MACHINE ... 4 SAFETY REGULATIONS AND RESIDUAL RISKS ... 5 INTENDED USE ...
(manual or electric) spraying computer handbook (if fitted) optional accessories handbooks (marker, premix, cardan shaft, etc.) UNIGREEN reserves the right to make changes to the manual without prior warning and the normal printing cycles may vary slightly. GUARANTEE The enclosed card indicates the conditions of the UNIGREEN guarantee.
It is obligatory to keep all the plates with danger and safety signs in perfect conditions. If they get damaged or deteriorate, replace them in good time. Replace parts believed to be faulty with others indicated by UNIGREEN. NEVER try makeshift or hazardous solutions.
Please contact the agent in your zone, the nearest authorised workshop or UNIGREEN S.p.A. directly for any repairs the user feels they aren’t capable of performing alone. (see point 10.4) Due to the complexity of the equipment and the variety of technologies used (mechanical, hydraulic, oil-pressure and electrotechnical) operators must not dismantle or modify the equipment.
The UNIGREEN S.p.A. sprayers are identified by the CE plate (FIG. 1 ) bearing one of the marks indicated in the tables of the allowed fittings (TABLE N° 10 , page 19).
This symbol identifies the coupling points of the machine FIG. 2 STANDARDS OF REFERENCE: - MACHINES DIRECTIVE 2006/42/CE. - D.Lgs. 81/08 Unique text for safety and hygiene in working places. -UNI EN ISO 12100-1/Apr.2005 : Machinery safety - Fundamental concepts, general design principles - Part 1: basic terminology, methodology -UNI EN ISO 12100-2/Apr.2005 : Machinery safety - Fundamental concepts, general design principles - Part 2: Technical principles...
When you receive the machine, check that it is complete and no parts are missing. If there are any damaged parts, inform your local reseller or UNIGREEN directly in good time. When the machine is delivered, make sure you ask: that the machine is delivered with all of its parts fitted and that the fitting meets the requisites in table N°...
4.8.1 COMPONENTS OF THE PRESSURE REGULATOR Below you will find the indications for the main models fitted on Unigreen products. A main ON-OFF command: “open” lets the fluid flow into the circuit in use;...
When using the pressure regulator, scrupulously observe the instructions in the enclosed handbook, below you will find generic indications for the major models fitted by Unigreen. All the regulation and adjustment tests must be carried out with clean water. Pressure regulators without a volumetric valve (GCP3-way - RPN - RVA) Adjusting the maximum pressure valve put main control A in the drain position (“OFF”).
This reading is precise if the tank is on flat ground; the actual total capacity coincides with the highest number. All the filling systems fitted by Unigreen on their production machines or on request are antipollution and stop the liquid overflowing out of the tank.
4.13 WASHING THE SPRAYER Thoroughly wash the machine after each treatment pumping clean water through the circuit and clean the suction and delivery filters. Dirty equipment is very dangerous for the people and environment. Discharging the residues of washing in the environment without taking precautions is forbidden as this pollutes watercourses.
For major and important maintenance jobs we recommend using the normal UNIGREEN assistance service available from your reseller, using original UNIGREEN spare parts. EMPTYING TANK The MULTI-purpose unit is equipped with a tap for emptying the tank completely.
The user of the present machine can contact the collection centres instituted by the Local Authorities or the UNIGREEN Company directly, or request withdrawal by the dealer, in order to carry out correct disposal of the waste.
TABLE 4-5 TABLES OF DELIVERY OF NOZZLES FOR HAND LANCES TABLE OF DELIVERY IN LITRES / MIN. OF THE CONICAL NOZZLES FOR LEVER LANCE NOZZLE DIAMETER PRESSURE (BAR) cone direct jet cone direct jet cone direct jet cone direct jet cone direct jet cone...
TABLE 7 TABLE OF PROGRAMMED MAINTENANCE OPERATION Check the level and state of the oil Check the accumulator pressure Check the suction (hoses, pipes, unions) Check and clean the suction and delivery filters Check the pump fixing feet and screws in general Check the diaphragm and the oil and change if necessary Check the suction/delivery valves...
FULL MAX FITINGS Table of standard riggings supplied by UNIGREEN, special riggings must be agreed with the constructor. Multi-purpose Mobile Units with a higher capacity (800 - 1000 - 2000 litres) and cistern in organic glass or steel (galvanised or stainless) are available on request.
Page 20
Rinaldi, 105 - Loc. Cavazzoli (Reggio Emilia) - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.com internet: www.unigreen-spa.com member of the group Descriptions, indicative illustrations, UNIGREEN S.P.A. reserves the right to make variations or modifications without prior warning.