around this you can create a virtual outlet to function as the alarm trigger and limit
the number of times per day it triggers.
First create a virtual outlet. For instructions on how to do this, refer to the
Comprehensive Reference Manual or the Programming Forum where there's a 'sticky'
with the instructions. The easiest way to add a single virtual outlet is via the Apex
Display Module.
Apex Display: Setup – Outlet Setup – Add Outlet.
In this example the virtual outlet was named 'DDR_Low' and configured as:
Set OFF
If Swx4_1 OPEN Then ON
If Swx4_2 OPEN Then ON
If Time 08:01 to 17:59 Then OFF
If Time 18:01 to 07:59 Then OFF
Then in your email/sound alarm outlet add:
If Outlet DDR_Low = ON Then ON
This will prevent a low container level alarm from being emailed to you except at 8am and
6pm daily.