Simulate a Transmitter (SIMULATE mA) 3.2.3 Output Voltage dc (SOURCE V) 3.2.4 Output Millivolt dc (SOURCE mV) 3.2.5 Auto Ramp Function Ⅰ ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
Page 3
(SOURCE mV dc) LOOP Power General Specifications 5、 Maintenance and Calibrati Repair Cleaning Replace the Battery and Fuse 6、 Accessories Included Ⅱ ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
If charge the Calibrator, must be use the power adapter that is provided from Calibrator. Disconnect the power immediately and return it to detect and maintain if discover abnormal situations or excessive local temperature on charging. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
0-24mA , it can measures 0-20mA or 4-20mA current loop as well as measure voltage dc 0-100mV/0-10V. It is widely used to calibrate various loop current or voltage/current equipment. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
It would storage the current setting status before your turn off the calibrator and keep it on when you using it again. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
Page 7
When at full scale point, press key again to decrease the current or voltage with stepping of 25% of full scale (0-20mA/4-20mA)/(0-100mV) /(0-10V). ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
• 4 mA-20 mA =0%-100% (default value) • 0 mA-20 mA =0%-100% (optional) The selection will be saved until next change. 2.2 Display ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
Page 9
Check of the full scale (0%-100%) Loop Loop power The combination of unit symbol: mA /mV/V Auto ramp type Stepping direction indicate symbol Low battery ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
If the voltage over 10V the LCD will show “-OL-”. The lower display area ,shows the voltage value percentage. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
If the voltage over 100mV the LCD will shows “-OL-”. The lower display area ,shows the current value percentage. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
3) If the current over 24mA, the LCD will shows “-OL-”. The lower display area ,shows the current value percentage. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
Touch test lead probes to the circuit across the load or power source as shown below. If the current over 24mA, the display will show “-OL-”. The lower display area ,shows the current value percentage. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
Smooth ramp with rate of change 0%-100%-0% within 15s. Press any pushbutton (except pushbutton) or turn off the Calibrator to exit this function. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
4 mA-20 mA (0%-100% ) [default value] ; 0 mA-20 mA (0%-100%) [optional]; To change the output span, press simultaneously. The setting value for selection will be saved until next change. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
3) To disable this function, rotate the knob until the display shows “OFF”. 4) The Calibrator will exit automatically about 5s later or you press the knob. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
If low light On-site environmental,this intrument has backlight function.In normal mode, Press button , The backlight open, repeat this operations can close backlight. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
± (0.02% of reading+4 Counts) 4.3 MEASURE mA dc Range Resolution Accuracy Sampling resistor 0 ---- +24 mA 1 uA 10Ω ± (0.02% of reading+4 Counts) ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
Weight: About 400g, (including the rubber cover). Conformity to safety standards: Meet the standard of IEC 61010-1-95 CAT I, 30V; Meet the standard of EN61010-1 EN61326. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
6) Insert the battery cover make sure it is securely in place (check the polarity). 7) Restore the calibrator to its holster. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
Page 27
3) Lift off the battery cover on the back of the Calibrator as shown in fifure. 4) Remove the damaged fuse. 5) Insert the replacement fulse and restore the battery cover make sureit is securely in place. ADEL Instrumentation – 28 Rue de Stalingrad – 38300 BOURGOIN JALLIEU 1 – 04 74 93 06 37...
Need help?
Do you have a question about the CC-04 and is the answer not in the manual?
Questions and answers