Krampitz Tanksystem TTD Series Operation And Installation Instructions Manual

Double wall tank system for diesel fuel or mineral oil (fresh or spent oil)
Table of Contents

Advertisement

Quick Links

Operation and Installation Instructions TTD
for Double Wall Tank System for Diesel Fuel
or Mineral Oil (Fresh or Spent Oil)
Type TTD:
Tank No.:
Year of construction:
Any disclosure or duplication of this documents, commercial exploitation or communication of the contents is prohibited except
with the prior express approval of Krampitz Tanksystem GmbH. Any contravention can be prosecuted and compensation can be
claimed.
Issue 04/2011
www.krampitz.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TTD Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Krampitz Tanksystem TTD Series

  • Page 1: Table Of Contents

    Year of construction: Any disclosure or duplication of this documents, commercial exploitation or communication of the contents is prohibited except with the prior express approval of Krampitz Tanksystem GmbH. Any contravention can be prosecuted and compensation can be claimed. Issue 04/2011...
  • Page 2: Table Of Contents

    3.3 Setting up the TTD on feet / supporting column .................................. 18 3.4 First start-up ............................................18 3.5 Operation sequence ..........................................18 4. DOCUMENTATION ..........................................19 5. WARRANTY ............................................. 19 Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 3: Settings Of The Limit Sensor For Day Tank Ttd

    HI - Inside height X-ÜSI - Settling dimension for Overfi ll guard TTD 1950 Y - Control dimension Specifi cations may change as design revisions take place! Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 4: Preliminary Note

    The TTD is subject to recurrent testing and inspection after the initial start-up. Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 5: Operation Procedures

    * after instruction by manufacturer * * if installed - probes 1.2.6 Handling of fuel oil, Diesel fuel and mineral oil: Observe all applicable general safety instructions. Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 6: Description

    TTD 750 1.510 1.530 TTD 990 2.010 2.030 TTD 1500 1.800 1.730 2.010 2.030 1.000 1.005 1.130 TTD 1950 2.300 2.190 2.010 2.030 1.250 1.005 1.130 Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 7: Connections Of The Ttd

    Suction socket leakage indicator Level meter, Switching contacts for Float switch top and bottom limits Overfi ll guard Limit monitor with Double wall vessel design approval Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 8: Units Of The Ttd - Standard Equipment

    NOTE Work on or tampering with the ball valve is forbidden and will void all warranty claims. Inform the manufacturer if the vacuum drops. Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 9: The Nameplate

    Every TTD storage tank is provided with a nameplate according to general inspectorate certifi cate No. Z-38.12- 23. Placed on the right side of the nameplate is the logo of the manufacturer Krampitz Tanksystem GmbH. All relevant data of the tank (manufacturer’s number, year of production, test pressure, tank capacity, material, etc.) is placed in the center of the nameplate.
  • Page 10: The Machine Return Pipe

    fi ned levels in the tank. When a 4-way cable gland is used, up to four level switches can be installed in a tank. CAUTION Observe the specifi cations of the switch. Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 11: The Electronic Volume Indicator

    96,6% 72,69 31,2% 162,68 64,4% 238,78 97,7% 142,91 31,5% 310,34 66,2% 461,05 98,7% 78,31 33,3% 168,30 66,5% 242,26 99,8% 153,38 33,6% 320,81 67,2% 242,26 99,8% Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 12: Bearing Charts For Ttd 750, Ttd 990, Ttd 1500 And Ttd 1950

    1.193,95 65,6% 1.796,90 99,4% 721,92 31,8% 1.510,43 65,6% 2.276,57 99,4% 587,57 32,8% 1.212,90 66,6% 745,81 32,8% 1.534,32 66,6% 606,52 33,8% 1.231,85 67,6% 769,71 33,8% 1.558,22 67,6% Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 13: The Electronic Leakage Indicator

    Vacuum remaining when alarm is triggered is suffi cient to prevent 6 Suction line connection the entry of stored medium in the environment. 7 Exhaust line connection 8 Measuring line connection Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 14: The Oil Warning Sensor With Alarm And Evaluation Unit

    The limit sensor should be adapted to the highest permitted fi lling level of the tank. (Also refer to limit sensor installation instructions). Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 15: Overview: Possible Switching Points And Control Instructions

    Tank volume Voltage Wall brackets type WK 2 WK 3 220 W up to 2,000 litres 230 V, 50 Hz weight/pair 12 kg 18 kg Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 16: The Supporting Column

    In the event that the colour coat is damaged, corrosion brackets on the wall or be attached to the wall anchor. protection must be properly restored. Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 17: Setting Up The Ttd On Feet / Supporting Column

    • fi lling level per level indicator to check again • if necessary, open the ball valves at the system fl ow connection • The TTD is now ready to use Krampitz Tanksystem GmbH - Operation and Installation Instructions TTD for Tank System - Issue 04/2011...
  • Page 18: Documentation

    Krampitz Tanksystem GmbH.
  • Page 19 Krampitz Tanksystem GmbH Headquarters: Dannenberger Str. 15 21368 Dahlenburg/Lbg. Germany Tel.: +49(0)5851/9443-0 Fax: +49(0)5851/9443-21 Offi ce: Siedlung des Friedens 40 29410 Hansestadt Salzwedel Germany Tel.: +49(0)3901/3088-100 Fax.:+49(0)3901/3088-131 Henningen plant: Henningen 78 29410 Salzwedel/OT Henningen Germany Tel.: +49(0)39038/9078-0 Fax: +49(0)39038/9078-10 Internet: www.krampitz.de...

This manual is also suitable for:

Ttd 250Ttd 500Ttd 750Ttd 990Ttd 1500Ttd 1950