Dateq SPL-D3 Manual

Multi color display & sound level logger

Advertisement

Quick Links

SPL-D3
Multi Color Display
&
Sound level logger
Manual
SPL-D3_200101_V1.0EN

Advertisement

Table of Contents
loading

Summary of Contents for Dateq SPL-D3

  • Page 1 SPL-D3 Multi Color Display & Sound level logger Manual SPL-D3_200101_V1.0EN...
  • Page 2 Due to the nature of this product and it's designed functionalities it is considered to be used and installed solely by professional and certified installers and is not intended for consumer usage or resale. Consumer use is not supported by the manufacturer. SPL-D3_200101_V1.0EN...
  • Page 3 DATEQ SPL6 Manual Safety instructions Safety instructions 1. All safety instructions, warnings and operating instructions must be read first. 2. All warnings on the equipment must be heeded. 3. The operating instructions must be followed. 4. Keep the operating instructions for future reference.
  • Page 4: Table Of Contents

    Index Safety instructions..........3 Configuration license........21 Introduction............7 Unlocking the limiter........21 Installation............8 Live..............22 Connections...........8 Display configuration........23 Link; ............9 Microphone..........24 Microphone input........9 Illumination..........24 Operation............10 Time slots............24 Technical specifications........13 Circuit breaker.........24 Inputs............13 Calibration..........25 Common............13 System............25 Introduction configuration.........19 History..............26 Installation............20 Product support..........29 Configuration..........20...
  • Page 5: Introduction

    Introduction Introduction The SPL-D3 is an advanced audio level display that stores the sound level samples for at least twelve months. The sound level samples can be viewed using the configuration software or externally stored through on a USB FAT32 drive. Other important data is also stored like powering up, sanctions or possible tampering.
  • Page 6: Installation

    Installation DATEQ SPL-D3 manual Installation The SPL-D3 is installed apart from the audio source (a mixing desk for example) and the speakers and amplifier. Image 1: Installing the SPL-D3 After installation and calibrating the SPL-D3, the SPL-D3 will show all measured values in green, orange or red within +/-1,5dB.
  • Page 7: Link

    DATEQ SPL-D3 manual Installation USB port; USB-A female Function Description 1 VCC + Supply 2 Data – Data 3 Data + Data 4 GND Ground Table 4: USB connections Link; Jack 3-pens female Function Description SL Ground Data ground Tip Data TX...
  • Page 8: Operation

    6. USB-A connection: Allows an external FAT32 drive to export measurement data from past 30 days. 7. Push button: Allows to export measurement data to external FAT32 drive, display SPL-D3 IP address or reset the SPL-D3 IP address. 8. Seal:...
  • Page 9 DATEQ SPL-D3 Manual Operation 9. Microphone: 3 pin XLR connection for DCM-5 microphone. 10.Link: Link connection for data link with SRL-1 stage relay, SPL-5MK2 or SPL6. 11.USB: USB-B connection for configuration with a windows computer. 12.Ethernet: Ethernet connection for IP link to internal webserver and remote report server* *Ethernet connection is disabled is first release firmware.
  • Page 10: Technical Specifications

    17.VESA 50: Standard VESA 50 mount for wall mount, M4, max length 12mm. 18.Standard: Standard mounting bracket provided with the SPL-D3, M4, max length 12mm Standard mounting bracket for M10 G-hook mounting. M4, max length 12mm 19.Safety mount: M5 DIN screw for mounting an extra safety cable. Max screw length: 12mm...
  • Page 11: Technical Specifications

    DATEQ SPL-D3 Manual Technical specifications Technical specifications Inputs Mic (Measurement microphone) XLR-3 female. Use only the original DCM-5 microphone. Common Audio Frequency response 30Hz...16kHz @ -1,5dB Signal/ noise ratio >90dB Memory 4GB SDHC 365 days * sound pressure information (resolution 1 minute)
  • Page 13 SPL-D3 Multi Color Display & Sound level logger Configuration...
  • Page 14 Notes...
  • Page 15 Index Safety instructions..........3 Configuration license..........21 Introduction.............7 Unlocking the limiter.........21 Installation...............8 Live..............22 Connections............8 Display configuration........23 Link; ..............9 Microphone..........24 Microphone input...........9 Illumination..........24 Operation..............10 Time slots............24 Technical specifications........13 Circuit breaker..........24 Inputs...............13 Calibration...........25 Common............13 System............25 Introduction configuration........19 History..............26 Installation.............20 Product support............29 Configuration............20...
  • Page 16: Introduction Configuration

    DATEQ SPL-D3 Manual Introduction configuration The SPL-D3 is an advanced audio level display that stores the sound level samples for at least twelve months. The sound level samples can be viewed using the configuration software or externally stored through on a USB FAT32 drive. Other important data is also stored like powering up, sanctions or possible tampering.
  • Page 17: Installation

    Always use the latest software and firmware release that can be found at www.dateq.nl. Configuration In this chapter the configuration and system settings for the SPL-D3 are explained. These settings normally are made once on installation. All made settings can be stored in a backup file for later use or restoring the original settings after changing.
  • Page 18: Configuration License

    SPL limiter and settings need to be changed, you need to contact your local distributor or installer. The closest supplier can be found at the Dateq selling points part of the website: www.dateq.nl. An installer license is linked and registered to the installing company and can not be transferred to third parties.
  • Page 19: Live

    DATEQ SPL-D3 manual Installation Live The live view of the software allows to monitor the SPL-D3 current measurements. These displays follow in color of the actual display in green orange and red.
  • Page 20: Display Configuration

    Installation DATEQ SPL-D3 manual Display configuration The manual configuration of sound level parameters. Displays All three displays can be set to different frequency responses, times and colors. Frequency filters: A-weight filter • C weight filter • Unweighted Flat filter (Z) •...
  • Page 21: Microphone

    The time and date are set manually by synchronizing the display time to the connected computer time. Circuit breaker The SRL1 circuit breaker can be linked to SPL-D3 to act as a warning or cut power on overshooting the maximum set dB level. The source of the dB value can be selected to one of the three displays.
  • Page 22: Calibration

    Installation DATEQ SPL-D3 manual Calibration The calibration allows to test all display LED's and to calibrate the used microphone. LED test: Tests all LED's in green, Orange and Red. Microphone: Use a standard approved class 2 calibrator at 94dBA and click on Microphone. The microphone will now be calibrated to the applied reference source and be internally recalculated to mV/pA.
  • Page 23: History

    The SPL-D3 logs all measured values and stores these encrypted into it's internal memory. Attempts to alter measured sound sample data within the SPL-D3 is prevented and will result in a defective unit that can only be restored at the Dateq service desk.
  • Page 24 Installation DATEQ SPL-D3 manual...
  • Page 25 DATEQ SPL-D3 manual Installation...
  • Page 26: Product Support

    Installation DATEQ SPL-D3 manual Product support For questions about the SPL series limiters, accessories or other products contact Dateq at: Dateq Audio Technologies B.V. De Paal 37 Phone: (036) 54 72 222 1351 JG Almere E-mail: info@dateq.nl The Netherlands Internet:...

Table of Contents