SERIES IXC-850 Table of Contents W A T E R P U R I F I C A T I O N S Y S T E M Introduction / System Specifications ....................4 Principles of Reverse Osmosis ....................5 - Reverse Osmosis Process - Semipermeable membrane - Factors affecting membrane service life - Reverse Osmosis System Terms and Definitions...
SERIES IXC-850 Introduction / System Specifications W A T E R P U R I F I C A T I O N S Y S T E M INTRODUCTION SYSTEM SPECIFICATIONS Water is an important part of all process applications. In order to MODEL: ROS-IXC-850 always provide the highest quality of water to the end consumer,...
SERIES IXC-850 Principles of Reverse Osmosis W A T E R P U R I F I C A T I O N S Y S T E M I. Principles of Reverse Osmosis Technology 1. Pressure: Excessive pressure may deform and compress the membrane which can cause decrease water production.
SERIES IXC-850 Principles of Reverse Osmosis / Identifying System Components W A T E R P U R I F I C A T I O N S Y S T E M Feed Water Requirements 2. SYSTEM PRESSURE GAUGE: Glycerin filled pressure gauge (0 -300 psi).
Page 7
SERIES IXC-850 Identifying System Components W A T E R P U R I F I C A T I O N S Y S T E M 10. CONTROL BOX: The Reverse Osmosis system is designed to be automatically operated by an electronic controller. The EC-100 CAUTION! KEEP IN MIND THE RECOVERY (PRODUCT/ controller monitors the operation parameters of the system and REJECTION) SUGGESTED BY YOUR DEALER BASED...
SERIES IXC-850 Pre Installation References W A T E R P U R I F I C A T I O N S Y S T E M III. PRE INSTALLATION REFERENCES ALWAYS FOLLOW SAFETY PROCEDURES WHEN Inlet Feed Water - enters through the pre -filter housing. INSTALLING THE UNIT.
SERIES IXC-850 Programming the EC-100 Controller W A T E R P U R I F I C A T I O N S Y S T E M VI. PROGRAMMING THE EC-100 CONTROLLER The Timer on the screen changes under different cycles of time, at the beginning it shows (minutes: seconds) and later when it reaches one hour changes to (hour: minute).
SERIES IXC-850 Information displayed on screen W A T E R P U R I F I C A T I O N S Y S T E M INFORMATION DISPLAYED ON SCREEN: SETTING PARAMETERS: Timer - Indicates the time the system has P1 - Time Setting adjustment for the duration of the membrane TIMER 1:00...
SERIES IXC-850 Cable connection identification W A T E R P U R I F I C A T I O N S Y S T E M CABLE CONNECTION IDENTIFICATION: TDS SENSOR CALIBRATION (CONTROLLER): - The controller has a basic TDS sensor that gives you a reading Violet: Low level Switch in the raw water tank (SW1) (*) of the quality of your product water that fills your tank.
SERIES IXC-850 Start-Up W A T E R P U R I F I C A T I O N S Y S T E M VII. START-UP WARNING: THE REVERSE OSMOSIS SYSTEM MUST BE FLUSHED THOROUGHLY FOR ONE HOUR BEFORE USING 1.
SERIES IXC-850 Troubleshooting Guides W A T E R P U R I F I C A T I O N S Y S T E M VIII. TROUBLESHOOTING GUIDES SYMPTOM POSSIBLE CAUSE SOLUTION Power switch is off. Place in AUTO position. Check power outlet and make sure system is plugged in.
Page 14
SERIES IXC-850 Troubleshooting Guides W A T E R P U R I F I C A T I O N S Y S T E M SYMPTOM POSSIBLE CAUSE SOLUTION Saturated or dirty membrane. Check, clean, replace if necessary. Check your feed water temperature, check your correction factor NO PRODUCT OR TOO LITTLE The water temperature is very low.
SERIES IXC-850 Reverse Osmosis Pre-Treatment / System Components W A T E R P U R I F I C A T I O N S Y S T E M IX. PRE-TREATMENT REQUIRED FOR Various filtering materials such as: multimedia, silica sand, REVERSE OSMOSIS SYSTEMS.
SERIES IXC-850 Electrical Installation Options W A T E R P U R I F I C A T I O N S Y S T E M ELECTRICAL INSTALLATION OPTIONS OPTION 1: When using atmospheric storage tank Level / Output Switch connection coming from AQT-EC-100 Controller (Green Wires located...
SERIES IXC-850 Liability and Warranty W A T E R P U R I F I C A T I O N S Y S T E M The products described in this document are hereby offered for sale to be established by Hydrofit Quick Connect Fittings, Polaris Scientific by any taxing authority, the Buyer shall promptly indemnify and hold the Seller harmless from and against any such tax, as well as any interest Ultraviolet, Hydron Membranes, Aquatrol, Shok Blok, HydroGuard, Hydronix Water Technology, any of its subsidiaries and its authorized or penalties thereon which may be assessed if the items are held to be taxable.
Page 18
SERIES IXC-850 Notes W A T E R P U R I F I C A T I O N S Y S T E M TRITTON IXC Page 18 of 20 P.O. Box 2235 Chino Hills, CA 91709 •...
Need help?
Do you have a question about the IXC-850 Series and is the answer not in the manual?
Questions and answers