Alarm Codes - Air innovations WINE GUARDIAN DS025 Installation, Operation And Maintenance Manual

Ducted split wine cellar cooling systems
Table of Contents

Advertisement

Alarm Codes

High temperature
alarm
Flashing temperature
number
Low temperature
alarm
Flashing temperature
number
High humidity alarm
Flashing humidity
number
Low humidity alarm
Flashing humidity
number
!1 = High Pressure
Switch Fault
!2 = CS (Condensate
Switch Fault)
67
Flashing temperature number along with (!)
symbol will remain on screen until
temperature falls below the High
Temperature Alarm set point (Setting 3).
Flashing temperature number along with (!)
symbol will remain on screen until
temperature rises above the Low
Temperature Alarm set point (Setting 2).
Flashing humidity number along with (!)
symbol will remain on screen until humidity
falls below the High Humidity Alarm
setpoint (Setting 5).
Flashing humidity number along with (!)
symbol will remain on screen until humidity
rises above the Low Humidity Alarm set
point (Setting 4).
THIS ALARM FORCES THE SYSTEM
TO SHUT DOWN
(!1) will remain on screen until the High
Pressure reset switch has been reset.
See the trouble shooting guide page 57 for
"Instructions to Reset High Pressure
Switch".
THIS ALARM FORCES THE SYSTEM
TO SHUT DOWN
(!2) will remain on screen until the CS
(condensate switch) fault is resolved and
reset.