Do you have a question about the Pack-Vac and is the answer not in the manual?
Questions and answers
Summary of Contents for Haug Pack-Vac
Page 1
Instruction Manual Pack-Vac™ Leak Detector CAUTION Filling the Pack-Vac with water warmer than ambient temperatures may cause thermal expansion of the plastic and the tank may crack. This is not covered under warranty.
Setup The Pack-Vac is very easy to assemble and operate, just attach a compressed air line to the ball valve on the right side of the base 86 P.S.I. (6 bar) minimum. For electric units, plug into appropriate power source.
Page 4 of 12 General test method The most common way to use the Pack-Vac™ is the bubble emission test. Fill unit with enough water to submerge package when expanded. Water level will rise as pack- age is expanded under vacuum.
Gases are much more easily seen than liquid product. Some products can be tested with lid film down using the dry chamber method, looking for product (see page 4). Haug Quality Equipment : 775-455-4249 2530 Wrondel Way www.haugquality.com...
Air cargo holds are typically pressurized to only 9,000 feet (2,743 meters). The Pack-Vac™ can reveal potential weaknesses in the package before shipping. Altitude simulation can be done wet or dry. Vacuum levels can be converted to altitude with chart. Alti- tude reading will be a differential from current altitude.
Close lid and start the vacuum at a very low level. It may be necessary to lower incoming air pressure with the regulator on CA units. Package expansion is slower with the Vac-Pack™ at- tachment in use. Figure 2. Figure 1. Haug Quality Equipment : 775-455-4249 2530 Wrondel Way www.haugquality.com Reno, NV 89502...
"look" of the expanded package more than trying to maintain a certain vacuum level. With some research and training, the Pack-Vac will become an integral part of your quality control program. General test parameters can be set up as follows: ...
Pack-Vac™ Cleaning The Pack-Vac™ tank should be cleaned on a regular basis with mild soap and water to remove mineral deposits before they degrade the clarity of the plastic. Using water with lower mineral content will delay mineral build-up. Commercially available plastic polishers and cleaners by Novus can be used. Availa- ble from www.mcmaster.com...
Page 11
Page 11 of 12 Press the remaining portions of the gasket into the groove. Close the lid. Loosen and retighten hinge screws to set lid height. Haug Quality Equipment : 775-455-4249 2530 Wrondel Way www.haugquality.com Reno, NV 89502 sales@haugquality.com...
Page 12 of 12 Parts List Haug P/N Title Detail Vendor Vendor P/N 114827 Tank & Lid Assy. 110808 110808 Haug 114826 Tank & Lid Assy. 181210 181210 Haug 114828 Tank & Lid Assy. 201413 201413 Haug 114829 Tank & Lid Assy. 242015...