Do you have a question about the Olymp HairMaster and is the answer not in the manual?
Questions and answers
Summary of Contents for Belvedere Olymp HairMaster
Page 3
_GA_HairMaster_GB.book Seite 29 Donnerstag, 6. September 2012 10:09 10 Device description Schematic representations on the interior ® ® HairMaster , mounted on the support arm system, including: Overview of the HairMaster one horizontally rotatable extension arm and one height-adjustable spring arm. Both support arms are equipped with friction brakes which keep the device stable at the adjusted position.
Page 4
_GA_HairMaster_GB.book Seite 30 Donnerstag, 6. September 2012 10:09 10 Thank you very much ® Thank you very much for purchasing the new HairMaster Please read this instruction manual very carefully, abide by the safety notices and observe all operating and cleaning requirements. This instruction manual is an integral part of the device.
Page 5
_GA_HairMaster_GB.book Seite 31 Donnerstag, 6. September 2012 10:09 10 Notes on this document This instruction manual is intended for qualified personnel familiar with the Target group: Qualified personnel treatment of hair as a result of their professional training (in countries where certification is required based on legal regulations, qualified personnel must have been awarded the related certificate).
_GA_HairMaster_GB.book Seite 32 Donnerstag, 6. September 2012 10:09 10 Contents 1 Your safety is important to us 1.1 Prescribed Use ..................... 33 1.2 Incorrect Use ......................33 1.3 Explanation of the Safety Instructions and Pictograms ........34 1.3.1 Safety Instructions and Pictograms Used in the Instruction Manual... 34 1.3.2 Pictograms Complementing the Safety Instructions........
_GA_HairMaster_GB.book Seite 33 Donnerstag, 6. September 2012 10:09 10 1 Your safety is important to us 1.1 Prescribed Use ® HairMaster is a hairdressing device for the heat treatment and drying of Use as prescribed the hair on the customer's head. •...
_GA_HairMaster_GB.book Seite 34 Donnerstag, 6. September 2012 10:09 10 1 Your safety is important to us 1.3 Explanation of the Safety Instructions and Pictograms 1.3.1 Safety Instructions and Pictograms Used in the Instruction Manual WARNING: Damage to persons Refers to a dangerous situation which, if not avoided, can lead to death or severe injury.
_GA_HairMaster_GB.book Seite 35 Donnerstag, 6. September 2012 10:09 10 1 Your safety is important to us 1.4 Overview of the Safety Instructions Read these safety instructions very carefully before the first use of the device. • These instructions help you to protect yourself and other persons against potential hazards and prevent damage to the device.
Page 10
_GA_HairMaster_GB.book Seite 36 Donnerstag, 6. September 2012 10:09 10 1 Your safety is important to us Shooting up of the spring arm! The spring arm of the wall-mounted version / special Elastic force of the spring arm attachments is under pressure. If the dryer is removed from the spring arm, the spring arm may shoot up and lead to injury.
Page 11
_GA_HairMaster_GB.book Seite 37 Donnerstag, 6. September 2012 10:09 10 1 Your safety is important to us Load-bearing capacity of the wall bracket! The load-bearing capacity of the wall bracket is restricted to Load-bearing capacity of the wall the weight of the device. bracket Do not attach any additional loads to the wall bracket.
_GA_HairMaster_GB.book Seite 38 Donnerstag, 6. September 2012 10:09 10 2 Putting the Device into Operation 2.1 Packaging Materials We recommend keeping the packaging for possible returns during the warranty period. After this time, all packaging materials can be disposed of as prescribed (recycling). 2.2 Scope of Supply Check first whether all device components are present and in good condition.
_GA_HairMaster_GB.book Seite 39 Donnerstag, 6. September 2012 10:09 10 2 Putting the Device into Operation 2.3 Mounting the Device 1. Insert the column tube into the hole in the star base and then push it up against the plastic bearing Shooting up of the telescopic tube! The telescopic tube is under spring...
_GA_HairMaster_GB.book Seite 40 Donnerstag, 6. September 2012 10:09 10 2 Putting the Device into Operation 2.4 Positioning the Device for Hair Treatment When positioning the device for hair treatment, make sure that: • the distance D between the head and the two side arms is equal, •...
_GA_HairMaster_GB.book Seite 41 Donnerstag, 6. September 2012 10:09 10 2 Putting the Device into Operation 2.6 Switching the Device On and Off 1. To switch on the device: Switch the ON/OFF switch to I. 2. The program control runs the start routine; the programs are loaded: –...
_GA_HairMaster_GB.book Seite 42 Donnerstag, 6. September 2012 10:09 10 2 Putting the Device into Operation 2.9 Defining the User Interface Language By default, the user interface of the device shows different languages. Language setting In the D menu, the user can specify the desired EFAULT ETTINGS ANGUAGE...
_GA_HairMaster_GB.book Seite 43 Donnerstag, 6. September 2012 10:09 10 3 Programs and Program Control 3.1 Description of the Programs The program control includes two different types of programs (see overview): • Hair treatment programs: – Quick start, – Waving, – Coloring, –...
_GA_HairMaster_GB.book Seite 44 Donnerstag, 6. September 2012 10:09 10 3 Programs and Program Control effectiveness and healthy hair. 3.1.2 Service programs The service programs serve for device configuration and for the testing of different device functions. The Default Settings menu item provides a list of options for the adjustment of the device to an individual user profile.
_GA_HairMaster_GB.book Seite 45 Donnerstag, 6. September 2012 10:09 10 3 Programs and Program Control 3.1.3 Messages The following two types of messages are shown during operation: • Notes, • Error message or warnings. Notes: ® The program control of the HairMaster displays messages while the hair Notes treatment programs are in progress:...
Page 20
_GA_HairMaster_GB.book Seite 46 Donnerstag, 6. September 2012 10:09 10 3 Programs and Program Control Warnings are shown as combined picture/text information and must be acknowledged in order to be able to continue the hair treatment program. To acknowledge and deactivate the warning: Highlight the OK function key and then press P...
_GA_HairMaster_GB.book Seite 47 Donnerstag, 6. September 2012 10:09 10 3 Programs and Program Control 3.2 Operation of the Programs A hair treatment program is configured for the desired purpose and started afterwards. In the following, the W hair treatment program is AVING presented as an example in order to demonstrate the operation of these programs.
Page 22
_GA_HairMaster_GB.book Seite 48 Donnerstag, 6. September 2012 10:09 10 3 Programs and Program Control To return to the previous configuration menu: Highlight the B function key and then press P to activate it. Progress bar: After the program start, the progress of the program is documented in the progress menu D: •...
_GA_HairMaster_GB.book Seite 49 Donnerstag, 6. September 2012 10:09 10 4 Care and Maintenance 4.1 Cleaning The housing of the device is made of painted plastic; the star base and the Materials of the device column tubes are made of chromium-plated metals. Electric shock! Contact with energized components presents a danger to life from electric shock.
_GA_HairMaster_GB.book Seite 50 Donnerstag, 6. September 2012 10:09 10 4 Care and Maintenance 4.1.2 Cleaning the Rollers and Bearings When the rollers no longer run freely, clean the roller sleeves and also the roller axles if required. To dismount the rollers: 1.
_GA_HairMaster_GB.book Seite 51 Donnerstag, 6. September 2012 10:09 10 4 Care and Maintenance 4.3 Replacing the radiant heater Electric shock! Contact with energized components pre- sents a danger to life from electric shock. Before replacing the radiant heater, disconnect the device from the mains and secure it against unintentional start-up.
Page 26
_GA_HairMaster_GB.book Seite 52 Donnerstag, 6. September 2012 10:09 10 4 Care and Maintenance To dismount the radiant heaters: The radiant heaters are attached to their base by means of spring pressure. Replacing the radiant heater • To dismount a radiant heater, push one side into its base and then remove the opposite contact block from the radiant heater base...
_GA_HairMaster_GB.book Seite 53 Donnerstag, 6. September 2012 10:09 10 5 Accessories The following articles can be ordered separately as accessories or parts subject to wear and tear. Filter kit including 20 filter fleeces Parts subject to wear and tear / tools Base foot roller, one part Roller lever (tool) Cable bracket, stand...
Page 28
_GA_HairMaster_GB.book Seite 54 Donnerstag, 6. September 2012 10:09 10 6 Technical Data The rating plate of your device is attached at the bottom of the device. Rating plate Length of the dryer 660 mm Dimensions Width of the dryer 580 mm Maximum height of the stand (including dryer) approx.
Need help?
Do you have a question about the Olymp HairMaster and is the answer not in the manual?
Questions and answers