PC0144 Relay
Quick Start Guide
Product Features
1
Power Indicator
RJ45 Ports – Connect PanL Hub, another PanL Device or
2
Terminator
ID Switch – Refer to the ID Switch Configuration section
3
for more details
4
Status indicator - Refer to the PanL Relay LED Status
Indicator section for more details
USB – Reserved for factory use only
5
1W –Reserved for factory use only
6
7
Reset Button
8
DC Input/Solid State Relay (SSR) Control–
Refer to DC Input and SSR Control setup section for more
details
9
Relay Ports (RL1-RL4)-
Refer to Relay(RL1-RL4) setup section for more details
PanL Relay Setup
1.
To securely mount the device on a flat surface, M4 screws and nuts can
be applied at the side of the enclosure. (Not provided in the box)
2.
If connecting multiple PanL Relays to a single PanL Hub port in a daisy
chain configuration, set the ID switch. Refer to the section - ID Switch
Configuration for details.
3.
Connect RJ45 8P8C cable and add a terminator. Refer to the section
PanL Hub Connection for details.
4.
If using Relay (RL1-RL4) option, refer to the section Relay (RL1-
RL4) Setup for details.
5.
If using SSR Control option, refer to SSR Control setup for details.
6.
If using DC INPUT for external input sense, refer to the section DC
Input setup for details.
PanL Hub Connection
The PanL Relay is designed to be connected to a PanL Hub for power and data
via the P1 or P2 RJ45 ports. When a single PanL Relay is connected to a PanL
Hub port, the maximum length of the RJ45 cable shall not exceed 100 meters.
Connect the PanL terminator (provided in the PanL Hub package) to the
unconnected P1 or P2 port.
For multiple PanL Relay connections to a single PanL Hub port, the first
connection to PanL Hub and the subsequent connections in between the PanL
Relay devices must not exceed 50 meters in cable length each. A single PanL
Hub port can support up to 3 PanL Relay. The total combined cable lengths
must not exceed 100 meters. Connect the PanL terminator provided in PanL
Hub box to the last unconnected PanL Relay P1 or P2 port.
PanL Relay
Please visit
http://panlshop.com/warranty
code for warranty registration with the UUID and Product Key
below:
For multiple PanL Relay connections to a single PanL Hub port, the ID switch
at the back of the displays must be configured to be unique. Using a Philip
head screw driver, set a unique number for each display between 0-7 (do
not use 8-9). For example, if connecting 3 PanL Relay to a PanL Hub port,
you may set it as 0, 1, and 2. Relays connected to different PanL Hub ports
can share the same unique number.
The Relay (RL1-RL4) supports both AC and DC Loads and is rated at
AC250V/DC28V/10A max per relay. Below depicts 2 connection options:
DEVICES NORMALLY OFF (NO)
DEVICES NORMALLY ON (NC)
WARNING: ALWAYS SWITCH OFF POWER SUPPLY WHEN WIRING
The 4 DC input channels are designed to take in external DC inputs ranging
from 3.3V to 24V. It can be used as a feedback channel to sense the RL1-
RL4 and SSR activation. Setup connections are illustrated below:
or scan the QR
ID Switch Configuration
Relay (RL1-RL4) Setup
DC Input Setup

Advertisement

loading

Summary of Contents for PANL PC0144

  • Page 1 The PanL Relay is designed to be connected to a PanL Hub for power and data via the P1 or P2 RJ45 ports. When a single PanL Relay is connected to a PanL Hub port, the maximum length of the RJ45 cable shall not exceed 100 meters.
  • Page 2 PanL Relay LED Status Indicator The table below depicts the different status which are represented by different color codes. Once the communication to PanL Hub is successfully established and enters operating mode, LED 1-8 will represent the relay operating and relaxed states. LED 1 to LED 4 corresponds to RL1 to RL4 and LED 5 to LED 8 corresponds to SSR 1 to SSR 4.