Caresono PadScan HD 5 Plus User Manual

Caresono PadScan HD 5 Plus User Manual

Bladder scanner
Table of Contents

Advertisement

Quick Links

PadScan HD 5 Plus
Bladder Scanner
User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PadScan HD 5 Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for Caresono PadScan HD 5 Plus

  • Page 1 PadScan HD 5 Plus Bladder Scanner User’s Manual...
  • Page 2 Feldstrasse 39, 4813 Address: Release Date: 2019.9.27 Altmuenster Austria Phone:0043-650 735 2000 Manufacturer: Caresono Technology Co., Ltd Address:4th Floor, N0.11Building, Initiating Zone, Instruments and Meters Industry Base, Near Port Industry Zone, Dandong, Liaoning, China Tel:+86 415 6279782Fax: +86 415 3191279...
  • Page 3: Table Of Contents

    By AC Adapter ................................8 By Battery ................................. 8 POSITIONING THE PROBE AND OBTAINING OPTIMAL IMAGES ................9 PADSCAN HD 5 PLUS SCANNER SCREENS AND BUTTONS ..................11 Login Screen ................................11 Home Screen ................................11 Expert Mode ................................11 Easy Mode ................................
  • Page 4 Cleaning the Probe ..............................35 Probe Maintenance ..............................35 Battery Use and Maintenance ..........................35 Treating and Disposing of Products After Use ......................36 TECHNICAL SPECIFICATIONS AND GENERAL SYSTEM INFORMATION ..............37 Component Specifications* ............................. 37 Operating Conditions............................... 37 Transportation and Storage Conditions ........................37 Transporting the System ............................
  • Page 5: Introduction

     Power supply available by AC adapter and a built-in battery. Intended Use The PadScan HD 5 Plus is used for measuring the urine volume in the bladder noninvasively by projecting ultrasound energy through the lower abdomen of the patient to obtain images of the bladder.
  • Page 6 The PadScan HD 5 Plus Bladder Scanner has been tested and found to comply with the electromagnetic compatibility (EMC) limits for medical devices to IEC 60601-1-2:2014, IEC 60601-1-2-37: 2007 + A1: 2015. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation.
  • Page 7: Cautions And Warnings

     Check and maintain the device regularly.  Do not disassemble or attempt to repair the device and the probe. ONLY CARESONO-trained technicians may service the unit. Equipment Checks 1.
  • Page 8: Maintain Probe Safety

    Warning: Users will assume responsibility of the risks associated with the use of the device after recommended service life. Manufacturer Declarations WARNING! Changes or modifications not expressly approved by CARESONO could void the user’s authority to operate the equipment. Warning: It is strictly prohibited to perform any modifications to the device without prior permission.
  • Page 9: Equipment Unpacking And Installation

    When you receive a PadScan HD5 plus, perform a full visual inspection of the device for any obvious physical damage that may have occurred during shipment, and then check the components and accessories against the packing list. A standard PadScan HD 5 Plus system is included with:  1 main unit ...
  • Page 10: Installation

    USB slot for flash disk probe connection port PadScan HD 5 Plus side connection ports printer paper dispenser PadScan HD 5 Plus back Installation 1. Battery Insertion and Removal: Slide the battery lock downward. Insert the battery into (or remove it from) the battery compartment, and then slide the lock back into the place.
  • Page 11 Secure the main unit by fixing its pendant slides into the slot on the docking station with the thumbs screws. thumbs screws pendant slides positioning column CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 12: Battery Charging And Status

    Power Supply PadScan HD 5 Plus is powered by two interchangeable methods: AC adapter and a built-in battery. By AC Adapter 1. Before each use, inspect the adapter for damage; verify the EPS is in the specified range.
  • Page 13: Positioning The Probe And Obtaining Optimal Images

    In order to correctly measure the volume of the bladder, grasp the probe shown as below: A green guideline visible on screen helps center the bladder. ((You can enable/disable this function from SETUP menu>Display>Central guide line ON/OFF) CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 14 In both Expert and Easy modes, a projection of the bladder in the crosshair is displayed at the right side on the screen. It helps re-aim and re-scan. (You can enable/disable this function from SETUP menu>Display>Projection ON/OFF) Please refer to APPENDIX C: RE-AIMING GUIDE for more information about how to re-aim and re-scan. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 15: Padscan Hd 5 Plus Scanner Screens And Buttons

    PADSCAN HD 5 PLUS SCANNER SCREENS AND BUTTONS Login Screen Operator: Tap to select user ID Password: Tap to type password Keyboard:use for typing Tap when ID and password are complete Home Screen Expert Mode Under this mode, the device is tended to use for locating the bladder through a real-time 2D ultrasound image scanned by a technician.
  • Page 16: Easy Mode

    Easy Mode It is designed to provide the guidance to help find the correct location of the bladder, but not to provide a real-time 2D scanned image. Crosshair Profile of the urine bladder CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 17: Patient Information Screen

    Tap to add Patient ID Tap to add Patient Name Keyboard for typing age Tap to clear content Tap to enter Patient data management Tap to confirm content entered Tap to cancel screen CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 18 Virtual keyboard to enter Patient ID Input patient ID Virtual keyboard Caps lock Confirm the content entered Switch between words and numbers Backspace Virtual keyboard to enter patient Name CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 19 B. On the Patient Information screen, age can be entered at a maximum of 3-digit number; It is required to enter or the following dialog box will appear on the screen; Null: No Age entered CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 20 Null: No name entered NOTE: If you want to go to the Home screen, tap the OK after you are finished entering all information requested. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 21 Review more details about the selected patient Upload through WIFI or USB Rescan or modify the selected patient Clear the scan result Previous page Next page P: Back to the previous screen Tap to enter instructional video CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 22 It takes about 1 seconds to export the scan results for one patient to the USB flash disk. NOTE: Do not remove the USB flash disk while the export is in process. NOTE: If you want to export the patient data through WiFi, ensure that the WiFi network is reliable CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 23 If you want to rescan the patient whose information has been stored, tap Rescan  Tap to clear patient data.  Tap Clear to clear up the selected or all patients’ scan results. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 24 On the Search screen, you may upload or delete patient scans on a batch basis If you enter the ID to be Searched, the display area on the left side will appear all patient data that satisfies your request. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 25  Add the Hospital Name, Department Name and Physician Name from [Tools]->[Option].  Review the ultrasound images of selected patient by click<Previous> and <Next>.  Print the Bladder Scanner Report from [Tools]->[Print]. Patient Data Management interface Report printout CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 26: Setup Screen

    Tap to add the department name. A maximum of 12 letters can be added. Tap to add date and time. Tap to start calibration (see page 24 for more information on how to calibrate) Tap for Language selection. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 27: Service

    NOTE: If you perform the System Recovery, the following settings will get back to defaults: Hospital Name, Department Name, Calibration Value, Exam mode (Expert Mode), Screen off time, Shutdown time, Operator’s name and password, and screen Display options. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 28: Operator

    If it’s turned off, the access is granted for all users without passwords. Operator log in (ON/OFF) User’s Name User’s Password Tap User and the Name Input screen appears. Input the operator’s name in this field. Input the user’s password in this field. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 29: Print

    D. Print to perform the Print settings and pick up one from 6 image groups to print out. (example: Image 1&7, Image 2&8, etc…). Each group contains two cross-sectional images. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 30: Power

    Display settings on Home screen. Tap ON or OFF to enable or disable the features. A: Display the largest volume obtained for the patient on Home screen. Display crosshair of project icon guide on Home screen Display central guide line in Expert mode CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 31: Wifi

    D: Tap to connect the WiFi after the WiFi is settled with account number WiFi signals refreshed area Set up WiFi A: add the WiFi’s account number add the WiFi’s password add the device’s IP address, net_mask, gateway by hand D: add the host’s IP address CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 32: Play

    H. Play to display onboard tutorial about installation, setup, operation and data transmission. Tutorial 1 Installation Tutorial 2 Scan Tutorial 3 Setup Tutorial 4 Data Transmission and Management CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 33: Quick Guide On How To Perform The Padscan Hd 5 Bladder Scanner

    2. Add Patient Information Tap Patient to add patient information. Tap Mode and select the appropriate icon. Tap ID, Age, Name to add corresponding information about the patient. Tap OK when you are finished. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 34: Prepare Patient And Position Probe

    Lift the probe once you hear it sounds ‘beep’ tone. The bladder volume will be displayed on the screen immediately after the scan is Scan analysis in progress Scan analysis complete complete in around 5 seconds. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 35: Re-Aim And Re-Scan

    6. View the scanned images Once the scan is finished, the measurement volume and six groups of sectional images of bladder will be displayed. Tap the LEFT or RIGHT arrows to view the six groups of images. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 36: Save Information

    Tap SAVE to save the exam data and results. 8. Print Tap PRINT to print the scan results. The printout contains the patient’s name,ID code, age, scan mode, scan time, bladder volume, and two ultrasound images. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 37: Calibration

     The calibration can only be done on Dansk Tissue Equivalent Phantom.  The Dansk Phantom should be equipped with the probe holder made by Caresono.  The probe head should be immersed by the water on the phantom surface completely; the probe head should touch the phantom surface.
  • Page 38: Troubleshooting

    3. Check if the power, the plug of the probe and the sockets are connected well. If problems continue, please contact Caresono technical support. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 39: Cleaning And Preventive Maintenance

    CLEANING AND PREVENTIVE MAINTENANCE The PadScan HD 5 Plus is non-immersible. It should be wiped down with a soft, clean cloth dampened with a cleaning solution such as soap and water, or a mild detergent solution, or as per hospital/clinic cleaning instructions.
  • Page 40: Treating And Disposing Of Products After Use

     For end of life product, waste electrical and electronic equipment should be collected separately and returned to the designated local recycling service.  Packaging waste should be collected separately for available national packaging collection and recycling services. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 41: Technical Specifications And General System Information

    Component Specifications*  Probe: 3D mechanical sector  Standard ultrasonic frequency of operation: 2.5MHz  Volume measure range: 0ml - 999ml.  Volume measure accuracy: ±15%, ±15ml (On Caresono tissue equivalent phantom)  Scan time: 7second ≤  Operation methods: touchscreen ...
  • Page 42: System Storage

    X-ray devices, broadcasting stations, or buried cables, etc... may introduce interference signals in the image. It is recommended to correct this by repositioning the PadScan HD 5 Plus, or increasing the separation between the PadScan HD 5 Plus and the interfering equipment.
  • Page 43: Symbols

    Not for general waste. Dispose of in accordance to Class II Electrical Equipment local regulations. Manufacture Date Manufacturer Handle with care Temperature limit Limited layers of storage Upwards Keep dry Keep away from sunlight Reference user's manual CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 44: Appendix A:labeling

    This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 45: Adapter Labeling

    The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Adapter Labeling Package labeling CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 46 CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 47: Appendix B: Acoustic Output Report

    APPENDIX B: ACOUSTIC OUTPUT REPORT CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 48: Appendix C: Re-Aiming Guide

    The following images show how to re-aim. Move the probe to down to the left Move the probe to down to the right Move the probe to up to the left Move the probe to up to the right CARESONO PadScan HD 5 Plus User’s Manual...
  • Page 49 Move the probe to the right Move the probe to the left Move the probe down Move the probe up CARESONO PadScan HD 5 Plus User’s Manual...

Table of Contents