Summary of Contents for Harman BSS Soundweb London BLU-103
Page 1
Soundweb London BLU-103 Installation Guide 5054331-A...
Page 2
IMPORTANT SAFETY INSTRUCTIONS WARNING FOR YOUR PROTECTION READ THE FOLLOWING: READ THESE INSTRUCTIONS. KEEP THESE INSTRUCTIONS. HEED ALL WARNINGS. FOLLOW ALL INSTRUCTIONS. The symbols shown above are internationally accepted symbols that warn of potential hazards with electrical products. The lightning flash with DO NOT USE THIS APPARATUS NEAR WATER.
Page 3
IMPORTANT SAFETY INSTRUCTIONS ELECTROMAGNETIC COMPATIBILITY DECLARATION OF CONFORMITY This device complies with part 15 of the FCC Rules and the Product Manufacturer’s Name: BSS Audio Specifications noted on the Declaration of Conformity. Operation Manufacturer’s Address: 10653 South River Front Parkway is subject to the following two conditions: Suite 300 •...
Page 4
CONSIGNES DE SÉCURITÉ IMPORTANTES AVERTISSEMENT POUR VOTRE SÉCURITÉ LIRE ATTENTIVEMENT : LIRE CES CONSIGNES. CONSERVER CES CONSIGNES. RESPECTER TOUS LES AVERTISSEMENTS. SUIVRE TOUTES LES CONSIGNES. Les symboles illustrés ci-dessus sont des symboles acceptés NE PAS UTILISER CET APPAREIL PRÈS DE L’EAU. internationalement qui avertissent des dangers potentiels relatifs à...
Page 5
CONSIGNES DE SÉCURITÉ IMPORTANTES DÉCLARATION DE CONFORMITÉ COMPATIBILITÉ ÉLECTROMAGNÉTIQUE Cet appareil est conforme au volet 15 des règles du FCC et aux Nom du fabricant : BSS Audio spécifications techniques évoquées dans la Déclaration de Adresse du fabricant : 10653 South River Front Parkway conformité.
Table of Contents Regulatory Information ����������������������������������������������������������������������������������������������������������� 1 Important User Information ��������������������������������������������������������������������������������������������������� 1 Mechanical Installation ����������������������������������������������������������������������������������������������������������� 1 Front Panel ����������������������������������������������������������������������������������������������������������������������������� 2 Analog Input/Output Channel Monitoring �������������������������������������������������������������������������������������������������������������2 Telephone Input/Output Channel Monitoring ��������������������������������������������������������������������������������������������������������2 Clip ������������������������������������������������������������������������������������������������������������������������������������������������������������������������2 Signal ���������������������������������������������������������������������������������������������������������������������������������������������������������������������2 48V (Input Channels Only) �����������������������������������������������������������������������������������������������������������������������������������2 OH (Telephone Channels Only) ���������������������������������������������������������������������������������������������������������������������������2 Other Indicators ����������������������������������������������������������������������������������������������������������������������������������������������������2 COM (Communications) ����������������������������������������������������������������������������������������������������������������������������������������2 STAT (Status) ����������������������������������������������������������������������������������������������������������������������������������������������������������2...
Regulatory Information An example of this equipment has been tested and found to comply with the following European and international standards for electromagnetic compatibility and electrical safety: Radiated Emissions (EU): EN55022:2010 Immunity (EU): EN55024:2010 Electrical Safety (EU): IEC60065-01 + AMD 2 Electrical Safety (USA): UL60065-03 Product Registration/Warranty...
Front Panel Analog Input/Output Channel Monitoring Telephone Input/Output Channel Monitoring Each input/output channel has the following LED indicators: The Telephone channel has the following LED indicators: Clip Indicates clipping in the analogue domain for each input or output channel� The LED will illuminate at +18�5dB�...
Rear Panel AC Mains AC Mains input to the universal switched-mode power supply, operates over a wide range of AC input voltages from 100V to 240V, 50/60Hz� Locate Pressing the Locate switch on the rear of the unit will illuminate the PWR LED on the front and identify the device within Audio Architect�...
Audio Cable Wiring All audio and GPIO connections to the BLU-103 are via Klippon pluggable terminal block connectors (also known as BL, Phoenix or Combicon)� The BLU-103 includes 3-way female Klippon connectors for individual channels� Audio Input & Output Wiring Convention Soundweb products provide cable shielding ‘back from the destination’...
Control Inputs There are 12 control inputs, also known as ‘General Purpose Inputs’ or ‘GPI’� The control inputs are used to connect contact closures (for control of binary parameters, such as mutes), resistor ladders (for control of multistate parameters, such as source selectors) or potentiometers (for control of continuous parameters, such as volume faders)�...
Logic Outputs There are 6 logic outputs, also known as “General Purpose Outputs” or “GPO”� They are used to control LED’s or relays� The logic output can source 10mA at 5V DC, or sink 60mA up to 50V DC� A high sensitivity relay (such as a reed relay) can be driven by connecting multiple logic outputs in parallel�...
Technical Specifications FRONT PANEL LED INDICATORS Input/Output: Signal Clip, Signal Present, 48V (input only), Off Hook (OH) Other: Control link status and activity for Ethernet and RS-232 connections (COM); Device configuration status (STAT); Error (ERR); Power/Locate (PWR) ANALOGUE INPUTS Connectors: 10 electronically balanced on Phoenix/Combicon removable screw connectors Mic/Line Inputs: Nominal gain 0dB, electronically switchable up to +48dB, in +6dB steps...
Page 14
OPTO (WATCHDOG) OUTPUT Connectors: Phoenix/Combicon connector for failsafe control Opto Output current: 14mA maximum Withstanding voltage: 80V maximum (Off) Series Impedance: 220 Ohms (isolated) CONTROL NETWORK Connectors: RJ45 Ethernet connector Maximum cable length: 100m/300ft on Category 5 or better cable between device and Ethernet switch Maximum number of nodes: BLU link AUDIO NETWORK Connectors:...