BURK Technology PlusConnect Nautel GV Installation And Operation Manual

Advertisement

Quick Links

PlusConnect™ Nautel GV
PlusConnect™ Nautel NV
PlusConnect™ Nautel NVLT
PlusConnect™ Nautel NX
PlusConnect™ Nautel VS
PlusConnect™ Nautel XR
Installation and Operation Manual Rev. F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PlusConnect Nautel GV and is the answer not in the manual?

Questions and answers

Summary of Contents for BURK Technology PlusConnect Nautel GV

  • Page 1 PlusConnect™ Nautel GV PlusConnect™ Nautel NV PlusConnect™ Nautel NVLT PlusConnect™ Nautel NX PlusConnect™ Nautel VS PlusConnect™ Nautel XR Installation and Operation Manual Rev. F...
  • Page 2: Table Of Contents

    Setting up Labels, Limits and Alarms ......................9 Creating a PlusConnect Custom View in AutoPilot ..................9 Operation ..............................11 Troubleshooting ............................11 Connection Errors ........................... 11 Getting Help ..............................11 Warranty ..............................12 Copyright © 2015 Burk Technology, Inc. Rev. F...
  • Page 3: Introduction

    ARC Plus before adding the PlusConnect to the system. Installation Note Even though you may operate the ARC Plus and PlusConnect on different subnets, Burk Technology strongly recommends installing the PlusConnect on the same LAN as the ARC Plus. In a network failure, an ARC Plus can only continue to monitor and control a PlusConnect on the same LAN.
  • Page 4: Compatibility

    Compatibility Transmitter Compatibility Model Compatible Transmitters PlusConnect Nautel GV Nautel GV3.5, GV5, GV7.5, GV10, GV15, GV20, GV30, GV40, GV60, GV80 PlusConnect Nautel NV Nautel NV Series PlusConnect Nautel NVLT Nautel NVLT Series PlusConnect Nautel NX Nautel NX Series PlusConnect Nautel VS Nautel VS300, VS300HD, VS1, VS1HD, VS2.5, VS2.5HD...
  • Page 5: Front Panel Indicators

    Front Panel Indicators Front panel of the PlusConnect unit Indicator State Description Power LED Power is on Power LED Power is off Link LED On (solid) ARC Plus and transmitter connections are good Link LED Blinking Transmitter connection is down Link LED ARC Plus connection is down Hardware Configuration...
  • Page 6 7. When prompted, enter the default password for the PlusConnect: password. Burk Technology PlusConnect Nautel XX v1.0.0 Password: 8. Telnet will display the main menu. 1. Log Off 2. Help 3. Set IP Address: 192.168.0.100 4. Set Subnet: 255.255.255.0 5. Set Gateway: 192.168.0.1...
  • Page 7: Additional Snmp Parameters

    NOTE: If the Allow another program button is un-selectable, click the Change Settings button first to unlock this. 9. Now click browse and search for the file C:\Program Files(x86)\Burk Technology\Burk Firmware Loader. 10. Select BurkFirmwareLoader and click Open and then click Add...
  • Page 8: Installation

    Run Burk Firmware Loader 11. Click Start >All Programs>Burk Technology>Burk Firmware Loader and launch the program. The dialog below will open. 12. Enter the IP Address, User Name and Password of the PlusConnect unit. Select the PlusConnect firmware file that you previously saved.
  • Page 9: Adding The Plusconnect Unit To The Arc Plus Site

    Adding the PlusConnect Unit to the ARC Plus Site In order for the ARC Plus to recognize the PlusConnect, the PlusConnect must be added to the site. 1. Open AutoLoad Plus and connect to the ARC Plus site to which you are adding the PlusConnect.
  • Page 10: Manually Mapping Plusconnect Parameters

    indicating the number of channel needed for the selected PlusConnect device: You do not need to have additional Integrated Input Units or Integrated Command Relay Units in order to use these channels. 10. Select File>Save to save the settings to the ARC Plus unit. Wait for the progress dialog to complete.
  • Page 11: Setting Up Labels, Limits And Alarms

    (There must be sufficient unused channel capacity.) Mapping additional channels is accomplished in AutoLoad Plus by selecting the Meter Channels, Status Channels or Commands tab, as appropriate. 1. Within any of these tabs, click the button at the right edge of the Source field to change a channel’s assignment from a traditional I/O channel to a Plus‐X channel.
  • Page 12 the default set of channels to the ARC Plus during setup. If you have mapped a custom set of channels, you can still use a Custom View to display them, but the template may not function as intended. To create a custom view with a PlusConnect template: 1.
  • Page 13: Operation

    Operation Once the PlusConnect parameters are mapped to ARC Plus channels using AutoLoad Plus, accessing the transmitter parameters is no different from any other ARC Plus channel. You may view channels using: • The front panel of the ARC Plus •...
  • Page 14: Warranty

    Warranty Burk Technology, Inc. warrants the PlusConnect to be free of defects in materials and workmanship for a period of 24 months from the date of purchase. Equipment will be repaired or replaced at the option of Burk Technology and returned freight prepaid to the customer. Damage due to abuse or improper operation or installation of the equipment or caused by fire or flood or harsh environment is not to be covered by this warranty.

Table of Contents