KV-XA25M30A/XA29M30A
RM-952
Blue
Neck assy
Red
VM1 board
Note
1. The Red and Blue magnets should be equally far from the
horizontal center line.
2. Do not separate the Red and Blue magnets too far. (Less
than 8 mm)
(2) Dynamic Convergence Adjustment
Preparation:
•
Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
R B
Red
Neck assy
Blue
VM1 board
TLH
R B
YCH
– 26 –
TLV
Rotate TLV-2 VOL (29", 34") on DY
XCV Rotate XCV Adj core on DY
YCH Rotate YCH VOL on DY
TLH
Insert
TLH
Correction Plate to DY Pocket (Left or
Right)
ON DY:
YCH
TLV2
B
R
TLV
R
B
XCV
TLV1
XCV