Manual
Platypus Sprinkler Specifications
Sprinkler Assembly and Cleaning Instructions
Flow Control Insert Specifications
System Maintenance
Warranty
Platypus Fire Pty Ltd
makers of the
PLATYPUS
PLATYPUS
PLATYPUS
CONTROLLER
CONTROLLER
CONTROLLER
The Sensible Bushfire Protection System
3
4
5
6
7-10
and

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PFSS25 and is the answer not in the manual?

Questions and answers

Summary of Contents for platypus PFSS25

  • Page 1 Platypus Sprinkler Manual Platypus Sprinkler Specifications Sprinkler Assembly and Cleaning Instructions Flow Control Insert Specifications System Maintenance Warranty 7-10 PLATYPUS PLATYPUS PLATYPUS CONTROLLER CONTROLLER CONTROLLER Platypus Fire Pty Ltd makers of the The Sensible Bushfire Protection System...
  • Page 2 Platypus Fire Pty Ltd makers of the The Sensible Bushfire Protection System Thank you for purchasing the Platypus Sprinkler. As part of our assembly and quality system, each sprinkler has been water tested using an operating pressure of 100kpa while mounted at 35 Please read supplied mounting diagrams and how to information to ensure the sprinkler is installed correctly.
  • Page 3 Platypus Fire Pty Ltd makers of the The Sensible Bushfire Protection System Sprinkler specifications Construction: • Overall height of the sprinkler is 81mm (A) • Width at the widest point is 51mm (B) Sprinkler Head • Weight is 85 grams •...
  • Page 4 Platypus Fire Pty Ltd makers of the The Sensible Bushfire Protection System Sprinkler assembly data and cleaning instructions 1/2” BSP Female thread Flange Retaining lugs Stainless steel inlet Bearing placed Stainless steel Plastic sprinkler shaft over inlet shaft nozzle screws onto...
  • Page 5 Platypus Fire Pty Ltd makers of the The Sensible Bushfire Protection System Flow control insert data sheet Length overall: 17mm Outside diameter: 15mm Flow rate: 5.5lpm to suit 2.5mm nozzle or 9lpm to suit 3.2mm nozzle, not available for 4.0mm...
  • Page 6: System Maintenance

    The Sensible Bushfire Protection System System Maintenance Platypus Fire PL recommends you carry out regular maintenance to ensure reliable operation of your sprinkler system and associated equipment. YEARLY - PRIOR TO BUSHFIRE SEASON • Remove, clean and inspect sprinkler shaft, bearing & heads •...
  • Page 7: Product Warranty

    1.1 In this Warranty the following definitions apply: Date of Purchase has the meaning set out in clause 3.2. Platypus means Platypus Fire Pty Ltd (ACN 159 992 355) of PO Box 466, Trafalgar VIC 3824 Australia. Purchaser means the purchaser of the Platypus Sprinkler.
  • Page 8: Making A Claim

    Term of the Warranty. 3. TERM 3.1 The Warranty is valid for one year from the date of purchase of the Platypus Sprinkler by the Purchaser. 3.2 The Date of Purchase of the Sprinkler is the date recorded on the receipt or invoice provided to the Purchaser at the time of purchase (“Date of Purchase”).
  • Page 9: Repair Or Replacement

    5.2 If a Sprinkler is to be replaced it may be replaced by products of similar design to the Sprinkler. 5.3 Platypus may engage a third party to replace or repair the Sprinkler at its sole discretion. 5.4 Replacement of the Sprinkler does not extend the Term of the Warranty.
  • Page 10: Transfer Of Warranty

    6.2 Platypus is not liable for any loss or damage arising from alterations to third party hardware or software. 6.3 Platypus is not liable for any loss or damage arising from loss of use, loss of profits or revenue. 6.4 Platypus is not liable for any loss resulting from indirect or consequential loss or damage.