Operating Instructions; Checking For Leaks; Operating Main Burners - Blue Rhino UniFlame GBC850WNG-C Owner's Manual

Blue rhino outdoor natural gas barbecue grill
Table of Contents

Advertisement

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
21
Insert Battery
F
x 1
Installing Natural Gas Line
Installation should be done by a qualified service person.
CAUTION: If young children are in the area, a locking valve should be
considered.
Connect Natural Gas Line
Before connecting, be sure that there is no debris
caught in the head of the natural gas line, head of the
grill natural gas line or in the head of the burner and
burner ports.
Connect grill natural gas line to natural gas line.
Disconnect Natural Gas Line
Before disconnecting make sure the natural gas line valve is "OFF".
Disconnect grill natural gas line from natural gas line.

Operating Instructions

Checking for Leaks

Burner Connections
Burner Connections
1. Make sure the regulator valve and hose connections
are securely fastened to the burner and the gas
line.
If your unit was assembled for you, visually check
the connection between the burner venturi pipe and
orifice. Make sure the burner venturi pipe fits over
the orifice.
WARNING: Failure to inspect this
connection or follow these instructions
could cause a fire or an explosion which
can cause death, serious bodily injury, or
damage to property.
2. Please refer to diagram for proper installation.
(Figure 1 and 2)
3. If the burner pipe does not rest flush to the orifice,
please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part
liquid dishwashing soap with three parts water.
2. Make sure control knobs are "OFF". (Figure 3)
3. Turn "ON" natural gas main valve.
4. Spoon leak check solution at all "X" locations
(Figure 4)
a. If any bubbles appear turn natural gas main valve
"OFF", reconnect and re-test.
b. If you continue to see bubbles after several
attempts, turn natural gas main valve "OFF"
and disconnect natural gas line and contact
1.800.762.1142 for assistance.
c. If no bubbles appear after one minute turn
natural gas main valve "OFF", wipe away solution
and proceed.

Operating Main Burners

First Use
1. Make sure all labels, packaging and protective films
have been removed from the grill.
2. Remove manufacturing oils before cooking on this
grill for the first time, by operating the grill for at
least 15 minutes on "HIGH" with the lid closed. This
will "heat clean" the internal parts and dissipate
odors.
page no.
9
Figure 1
Valve
NG Gas Valve
Soft Pipe
with Orifice
Connection
Burner
venturi
Main Burners
pipe
Figure 2
NG Gas Valve
Burner
with Orifice
venturi pipe
NG Gas
Connection
Valve
Side Burner
Soft Pipe
Connection
Figure 3
Figure 4

Advertisement

Table of Contents
loading

Table of Contents