  • Page 1 TIC600 Engineering survey installation instruction Zhejiang Uniview Technologies Co., Ltd. All rights reserved Document version V1.0 Release date 2020-03-28...
  • Page 2 Statements ● The contents of this manual will be updated from time to time, and the updated contents will be added to the new version of the manual without notice. ● The manual may contain technical inaccuracies or printing errors Safety precautions ●...
  • Page 3: Table Of Contents

    Catalog 1 Product introduction 2 Site Survey and Commissioning Guide 2.1 Scenario requirements 2.2 Installation requirements 2.3 Temperature measurement and screening system instructions 3 Debugging guidance 3.1 Computer host requirements 3.2 Computer network configuration 3.3 Temperature measurement software installation and device connection 3.4 Software version of equipment 3.5 Client software configuration 3.6 Visible camera software configuration...
  • Page 4: Product Introduction

    Product introduction TIC600 infrared thermal imaging temperature measurement and screening system is composed of human body temperature camera, human body temperature measurement blackbody and temperature measurement and screening software. Its main feature is non-contact temperature measurement, which is suitable for large-scale screening in the scene of train station, airport, bus station, hospital and school with large flow of people, so as to realize temperature anomaly warning.
  • Page 5: Installation Requirements

    2.2 Installation requirements ● Camera: no mandatory requirement, the recommended installation height is between 2-3 meters, with a depression angle is between 0-10 ℃. ● Blackbody: no mandatory requirement, the recommended installation height is between 1.5-2 meters, with a depression angle of 0 ℃ ●...
  • Page 6: Debugging Guidance

    ● The face needs to be focused clearly, so that camera can detect the skin surface such as forehead directly. ● The tested person should walk normally along the guide belt (no more than 2 steps per second), and look up at the camera when passing the detection area; 2.3.2 Screening instructions The core purpose of the temperature measurement and screening system is to screen the target of fever personnel from the normal temperature population, and then check it again through the medical...
  • Page 7: Temperature Measurement Software Installation And Device Connection

    3.3 Temperature measurement software installation and device connection 3.3.1 Software installation First, Click Install package”Inspection System version V X.X.X.X”, Second, Click “Browse” button to select software installation path, as shown in the figure below...
  • Page 8 Click “Next” and “Install” button to install After installation, wait for the system to configure itself, then press any key to continue...
  • Page 9 Uncheck the “Launch AVI Plugins” and “Launch VC Tools”, click “Finish” button to finish installation Finally, you can see “Inspection System” software on the desktop, Run the software as administrator 3.3.2 Device connection After opening the software with the administrator's permission, wait for the device to connect by itself.
  • Page 10: Software Version Of Equipment

    3.4 Software version of equipment Open the client software, enter the "System para” - > Advanced Configuration" interface, check the device software version, and confirm whether it meets the following requirements, If not, it is recommended to refer to the appendix Methods of software installation and upgrade for upgrading The computer client system version needs to be upgraded to V1.0.0.0 or later The version of infrared thermal camera system needs to be upgraded to IR-V3.03-20200328 or...
  • Page 11 A reference person needs to be standing at a distance of 5m from the camera for calibration (standing on the left and right side of the screen in turn). First, move the yellow calibration points on the infrared and visible images to the same position on the lower left corner of the image ((such as knee position).
  • Page 12 3.5.3 Temperature correction Enter “System para”-> “Temperature correction” interface When you need to view the actual body surface temperature of the target (such as the measurement test of the certification company), you need to uncheck "Enable" in Temperature compensation of armpit on body surface configuration interface, and uncheck " Automatic correction"...
  • Page 13 3.5.4 Alarm configuration Enter “System”->Alarm configuration interface. Adjust the alarm threshold according to the actual needs (37.3 ℃ is recommended)。 Confirm that "Enable Alarm" is selected. Click "Apply" to complete the setting. 3.5.5 Alarm record query In the menu bar, you can query the alarm record (the login password is “admin”), you can see the picture record on the left page.
  • Page 14: Visible Camera Software Configuration

    3.6 Visible camera software configuration 3.6.1 Detection area configuration Log in to the visible light device web page, open the “Setup”-“Smart”-“Face” interface, select "Specified Area" in "snapshot Area", but do not put the location of the blackbody into the detection range, as shown in the yellow box above.
  • Page 15: Appendix

    3.7.2 The device has detected high temperature but does not alarm 1. Check whether the alarm threshold is set correctly. Generally, the alarm threshold is set to 37.3 ℃. Check whether the alarm threshold is set too large. 2. No temperature measurement if no face is detected: the face temperature measurement version detects the face first and then measures the temperature, and automatically discards the temperature lower than 30 ℃...
  • Page 16: Equipment Assembly Instructions

    Client Infrared temperature measurement screening software software 4.2 Equipment assembly instructions 4.2.1 Equipment installation Open the tripod packing box and take out the tripod and tripod accessories. Take off the fixed base of tripod, then fix the base on the camera directly, finally install the camera to tripod, as shown in the figure: The installation in blackbody is the same as above...
  • Page 17 The effect of installation is as shown in the figure: The distance between camera and blackbody is about 2-5M. 4.2.2 Line connection Connect the two ends of the output cable to the camera and DC12V power adapter Plug the two ends of the into the output cable and the network port of the computer.
  • Page 18: Methods Of Software Installation And Upgrade

    4.2.3 Schematic diagram after assembly 4.3 Methods of software installation and upgrade 4.3.1 Client upgrade Uninstall the original client software first, and then open the task manager to confirm that no client related programs are running Open a new client software and run it as an administrator.。 4.3.2 Visible camera software upgrade Open IE browser, log in IP of 192.168.1.13, then log in user name of “admin”...
  • Page 19 4.3.3 Infrared thermal camera upgrated...