  • Page 1 AirSpeed 1050 Installation Guide Part Number: DUG01545 System Release: 16.0 Revision: A Published: June 2019...
  • Page 2 Airspan Networks Inc. reserves the right, without prior notice or liability, to make changes in equipment design or specifications. Information supplied by Airspan Networks Ltd. is believed in good faith to be accurate and reliable, while every care has been taken in preparing these documents.
  • Page 3: Table Of Contents

    DECLARATION OF CONFORMITY............... 7 GPS Compliance....................8 Maximum Output TX Total Power ............. 9 Power Consumption ....................9 Product Variants ....................9 Antenna System ....................10 About This Document ................11 Purpose ........................ 11 DUG01285-SP Airspan Commercial and Internal Use...
  • Page 4 AirSpeed 1050 Installation Guide Intended Audience ....................11 Related Reading ....................11 Customer Care Help Desk ..............12 Airspan Encourages Comments ................12 1 Introduction ..................13 1.1 AirSpeed 1050 ....................13 1.1.1 Deployment ....................13 2 Verifying Prerequisites ................. 15 2.1 Verify the Tools .....................
  • Page 5 Figure 33: Tighten the Strap Clamp ....................32 Figure 34: Align Marks + Click in Place .................... 32 Figure 35: Place Split Rubber Gland ....................32 Figure 36: Gland Size on Edge ......................33 DUG01545 Airspan Commercial and Internal Use...
  • Page 6 Table 1: AirSpeed 1050 ETSI Maximum Output TX Total Power ............9 Table 2: Power Consumption ......................9 Table 3: Variants ..........................9 Table 4. Hardware Requirements - Mounting ................... 15 Table 5: AirSpeed 1050 Components ....................15 DUG01545 Airspan Commercial and Internal Use...
  • Page 7 AirSpeed 1050 Installation Guide Table 6. AirSpeed 1050 Physical Dimensions .................. 17 Table 7. AirSpeed 1050 Environment Compliance ................18 Table 8: Outdoor Power Cable Requirements .................. 25 Table 9: Recommended Gland Size....................29 DUG01545 Airspan Commercial and Internal Use...
  • Page 8: Document Information

    AirSpeed 1050 Installation guide Document Information This document details procedures for installing the Airspan’s AirSpeed 1050 Pico-class LTE eNodeB variant. Document Approvals Department Name Approval date Role Product Management Product Line Manager R&D Digital HW Group Manager Revision History Document owner: Shlomi Tsur, PLM...
  • Page 9: Warnings And Cautions

    Failure to do so may void Airspan's product warranty and may expose the end user or the service provider to legal and financial liabilities. Airspan and its resellers or distributors are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas.
  • Page 10: Général

    Toute enfreinte a ces obligations peut annuler la garantie délivrée par Airspan pour ces produits et peut exposer l’utilisateur final ou le fournisseur de services a des dommages légaux et financiers.
  • Page 11: Securite

    Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations 1990). At the end of any Airspan products life cycle, the customer should consult with Airspan to ensure that the product is disposed of in conformance with the relevant regulatory requirements.
  • Page 12: Attention Aux Voltages Hasardeux

    Airspan equipment is compliant with CE and R&TTE regulations and can be operated in all EU (European Union) locations listed below:...
  • Page 13: Ul Information

    Use the grounding screws on the antenna bracket and the radio and antenna for terminating the ground wires. - The circuit ground must be connected to the same grounding system as the unit. DUG01545 Airspan Commercial and Internal Use...
  • Page 14: Outdoor Cabling

    Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC. Greek: ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Airspan ΔΗΛΩΝΕΙ ΟΤΙ Ο ΕΞΟΠΛΙΣΜΟΣ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ. Français: Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive 1999/5/EC.
  • Page 15: Gps Compliance

     EN 61000-4-6: Conducted Immunity  EN 61000-4-8: Magnetic Field Immunity A GPS is recommended for synchronizing between sectors. Note: An optional GPS Lightning/Surge protector is available from Airspan when installing the GPS Note: antenna in a remote location for lightning prone deployments. DUG01545...
  • Page 16: Maximum Output Tx Total Power

    AirSpeed 1050, 2.3 - 2.4 GHz (B40), Fiber, AirSpeed 1050 B40 Fiber Copper Backhaul, DC + copper BH, DC power AS105-U40-B08A AirSpeed 1050, 2.3 - 2.4 GHz (B40), Fiber, AirSpeed 1050 B40 Fiber Copper Backhaul, AC + copper BH, AC power DUG01545 Airspan Commercial and Internal Use...
  • Page 17: Antenna System

    AirSpeed 1050 Installation Guide Antenna System The AirSpeed 1050 includes embedded antennas: 2x SBA. Each SBA includes two antenna elements which can be switch on/off. Figure 1: AirSpeed 1050 DUG01545 Airspan Commercial and Internal Use...
  • Page 18: About This Document

    This guide is intended for persons who are responsible for installing the AirSpeed 1050 equipment. These persons should have a working knowledge of the equipment. Related Reading The following documents contain related information:  AirSpeed 1050 Product Datasheet  Airspan LTE Commissioning Manual Pending DUG01545 Airspan Commercial and Internal Use...
  • Page 19: Customer Care Help Desk

    Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must Note: have a valid support contract. To register, click here and fill the Registration form.
  • Page 20: Introduction

    AirSpeed 1050 Installation Guide 1 Introduction This section provides a descriptive overview of the Airspan’s AirSpeed 1050 variant(s) and its place in the Airspan product suite. AirSpeed 1050 is a standalone product with fiber and copper backhaul. It includes dual sector access with SBA antenna. The product is aimed for outdoor deployment, on a pole top or side as well as wall mounting.
  • Page 21: Figure 2: Airspeed 1050

    AirSpeed 1050 Installation Guide Figure 2: AirSpeed 1050 The illustration above displays the AirSpeed 1050 unit. Note: DUG01545 Airspan Commercial and Internal Use...
  • Page 22: Verifying Prerequisites

    Sems Hex-Head Bolt M8x20 ISO4017 Mounting KIT with 2 Washers-all A2 (x2) Mounting Kit (Pole) 903-03-350 Long Band  Maxi Clamp, band 14mm (9/16in) wide + quick adjust lock, 63-406mm (1/2- 16in) pole diameter. (x2) DUG01545 Airspan Commercial and Internal Use...
  • Page 23 Power AC - 3 position power(26mm pitch) Octis plug kit - AC 10143762-102LF 300-50-135 Screw Version & metal tie Octis plug kit W/O ETH - without RJ45 connector ,Right (R) 10135742-101LF 300-20-062 RJ45 connector) pitch 26mm DUG01545 Airspan Commercial and Internal Use...
  • Page 24: Physical Description

    Dimensions (H x D) Comment 195 x 430 mm (7.68 x 16.93in.) – including Dimensions bracket The physical dimensions exclude connectors 195 x 300 mm (7.68 x 11.1in.) – without bracket Volume Weight Main Unit 5.3Kg (11.68Lbs.) DUG01545 Airspan Commercial and Internal Use...
  • Page 25: Bottom View

     ETSI EN 300-019-1-2 Transportation Table 7. AirSpeed 1050 Environment Compliance Type Details Operating temperature -40°C to 55°C / -40°F to 131°F Operating humidity 5% - 100% non-condensing Storage temperature -40°C to 70° C / -40°F to 158°F DUG01545 Airspan Commercial and Internal Use...
  • Page 26 AirSpeed 1050 Installation Guide Type Details Rain and dust ingress protection IP66 DUG01545 Airspan Commercial and Internal Use...
  • Page 27: Installation Of Airspeed 1050

    Installation should take into consideration the antenna(s) and Sector(s) direction for maximum Note: coverage. Pole installation should be so the antenna(s) are positioned parallel to the street for maximum Note: coverage. Figure 5: Positioning Overview DUG01545 Airspan Commercial and Internal Use...
  • Page 28: Pole Mount Assembly

    Insert the clamp bands by passing them through the upper slots and the lower slots in the bracket, in two (2) places. When in the required position, tighten the clamp bands with a large screw driver. The mounting bracket is installed and ready for AirSpeed 1050 installation. DUG01545 Airspan Commercial and Internal Use...
  • Page 29: Wall Mount Assembly

    Attach the mounting bracket to the wall using wall plugs (x4) and appropriate screws rated for at least 8-10 Kg per fastener. Wall plugs (x3) and necessary hardware are not supplied by Airspan and are the Note: responsibility of the installer. Recommended 3/8” dia. with appropriate wall plugs according to field conditions.
  • Page 30: Securing The Unit To The Mounting Clamp Bracket

    Figure 7: Assembly on Pole Insert the two (2) Hex-Head (M8x20) bolts in the threaded holes and tighten to a torque of no more than 14 Nm (10 ft-lb) max. Figure 8: AirSpeed 1050 on Pole (Shown Wired) DUG01545 Airspan Commercial and Internal Use...
  • Page 31: Figure 9: Airspeed 1050 On Top Pole - Example (Shown Wired)

    Extension pole and any required hardware for mounting on top of a pole are not included in should be obtained by the installer. Figure 9: AirSpeed 1050 on Top Pole - Example (Shown Wired) AirSpeed 1050 mounted on a wall. Figure 10: AirSpeed 1050 on Wall DUG01545 Airspan Commercial and Internal Use...
  • Page 32: Connect And Manage Cables

    Hazardous voltage! Before working, ensure that the power is removed from the power Danger: connection cables. When the system is powered on, do not touch the power terminals. Airspan recommends the following outdoor Power cable requirements – Cable, 3C, SJOOW, 18AWG, Stranded, Outdoor. Table 8: Outdoor Power Cable Requirements...
  • Page 33: Ac Cable Preparation

    34mm max (1.34 in). Then strip back 8mm± 2 (0.31 in) of the inner core insulation. Figure 12: Stripping Dimensions (AC Cable) Open the housing lock by sliding up then lift the clamp handle. Figure 13: Open Housing Lock DUG01545 Airspan Commercial and Internal Use...
  • Page 34: Figure 14: Seperate Into Sections

    Insert the prepared ends of the cable into the inner part of the connector housing. Verify the wire polarity before securing. Caution: Figure 17: Insert Wire to Housing Verify the wires are in their correct stations. DUG01545 Airspan Commercial and Internal Use...
  • Page 35: Figure 18: Ac Wire Placement

    Insert into outer housing until “click” in place, align marks for proper alignment. Figure 20: Cable Click in Place 10. Place the split rubber gland onto the cable. Figure 21: Place Split Rubber Gland DUG01545 Airspan Commercial and Internal Use...
  • Page 36: Figure 22: Gland Size On Edge

    Gland nut with a 21mm wrench. Caution: Do not over tighten the Gland nut. The Gland nut should be tightened to a torque of no more than 2.5-3.0 Nm (1.84 – 2.21 ft-lb) max. Figure 24: Tighten Gland Nut DUG01545 Airspan Commercial and Internal Use...
  • Page 37: Dc Cable Preparation

    Strip back and remove the outer sheath to a length of 9.0mm± 2 (0.35 in) to expose the inner insulated wires to a length of 13.5mm± 2 (0.53 in). Then strip back 7mm± 2 (0.27 in) of the inner core insulation. Figure 27: Stripping Dimensions (DC Cable) DUG01545 Airspan Commercial and Internal Use...
  • Page 38: Figure 28: Open Housing Lock

    Loosen the strap clamp and feed the prepared end of the source power cable into the inner part of the DC connector housing. Figure 31: Pass DC Cable Thru Secure the prepared ends of the cable into the inner part of the connector housing and tighten the 2 screws. DUG01545 Airspan Commercial and Internal Use...
  • Page 39: Figure 32: Tighten Two (2) Set Screws

    Place the split rubber gland onto the cable. Figure 35: Place Split Rubber Gland For recommended gland size see Table 9: Recommended Gland Size The gland size is written on the edge of the gland. Note: DUG01545 Airspan Commercial and Internal Use...
  • Page 40: Figure 36: Gland Size On Edge

    11. Tighten the gland nut with a 21mm wrench, to a torque of no more than 2-2.5 Nm (1.47 – 1.84 ft-lb) max. Figure 38: Tighten gland Nut After tightening the gland nut, close the lever. Figure 39: Close the Lever DUG01545 Airspan Commercial and Internal Use...
  • Page 41: Fiber Ethernet (Sfp) Cable Preparation

    Diameter of cable is in the 5 to 7mm (0.20-0.28) range. Figure 41: Pre-assembled LC Duplex Cable Open the housing lock by sliding up then lift the clamp handle, Figure 42: Open Housing Lock Separate the housing into its component sections. DUG01545 Airspan Commercial and Internal Use...
  • Page 42: Figure 43: Gland Nut On Cable

    Inner diameter of rubber gland is in the range of 6 to 8mm (0.20-0.31) range. Figure 45: Insert Rubber Gland on Cable Pass the LC Duplex cable thru the housing. Figure 46: Pass Cable thru Housing DUG01545 Airspan Commercial and Internal Use...
  • Page 43: Figure 47: Insert Cable Into Transceiver

    10. Fix the holder into the housing base. A “click” is heard when engaged. Figure 49: Holder into Housing Base 11. Secure the holder into the transceiver, “click” when engaged. Figure 50: Holder into Transceiver DUG01545 Airspan Commercial and Internal Use...
  • Page 44: Figure 51: Lift Lever

    14. Push to insert the tightening cone. Figure 53: Insert Cone 15. Tighten the gland nut with a 21mm wrench, to a torque of no more than 2-2.5 Nm (1.47 – 1.84 ft-lb) max. Figure 54: Tighten Gland Nut DUG01545 Airspan Commercial and Internal Use...
  • Page 45: Copper Ethernet Cable Preparation

    Figure 57: Gland Nut on Cable Insert the “split tightening cone” from the side of the cable. For recommended gland size see Table 9: Recommended Gland Size Figure 58: Insert Tightening Cone on Cable DUG01545 Airspan Commercial and Internal Use...
  • Page 46: Figure 59: Insert Rubber Gland On Cable

    Insert the holder section onto the front of the RJ45. Figure 61: Insert Holder onto RJ45 Fix the holder into the housing base. A “click” is heard when engaged. Figure 62: Holder into Housing Base DUG01545 Airspan Commercial and Internal Use...
  • Page 47: Figure 63: Align Rj45 Into Holder

    10. Push the rubber gland to insert in place then push the tightening cone to insert in place. Figure 65: Insert Gland 11. Tighten the gland nut with a 21mm wrench, to a torque of no more than 2-2.5 Nm (1.47 – 1.84 ft-lb) max. Figure 66: Tighten Gland Nut DUG01545 Airspan Commercial and Internal Use...
  • Page 48: Figure 67: Secure Housing Lock

    12. Close the lever and secure the lock by sliding the secondary lock/button, so that lever can’t be lifted; assembly is now ready for insertion. Figure 67: Secure Housing Lock Figure 68: AC Housing Lock Secured DUG01545 Airspan Commercial and Internal Use...
  • Page 49: A Job Sheet

    Appropriate wrench’s for unit assembly Knife pliers Small side cutters Tweezers (or fine blade long nose pliers) Wire strippers Required Ancillary Equipment Laptop PC for initial configuration cable for temporary connection of the lap top DUG01545 Airspan Commercial and Internal Use...
  • Page 50: B Abbreviations

    File Transfer Protocol Long Term Evolution, marketed as “4G LTE”, is a standard for wireless communication of high-speed data for mobile phones and data terminals National Electric Code User Equipment WEEE Waste Electrical and Electronic Equipment DUG01545 Airspan Commercial and Internal Use...