    CONTENTS BASIC INFORMATION ABOUT WATER IONIZERS ............................PRODUCT DESCRIPTION ............................INSTALLATION ............................PRODUCT USAGE ............................INSTRUCTIONS ............................MINERAL PORT USE ............................IONIZER CARE ............................HOW TO CHANGE THE FILTER ............................WARNING ............................TROUBLESHOOTING ............................SPECIFICATIONS ............................Miracle Max Plus...
  • Page 4: Basic Information About Water Ionizers

    BASIC INFORMATION ABOUT WATER IONIZERS CONGRATULATIONS ON CHOOSING CHANSON® - THE HIGHEST QUALITY IONIZER BRAND IN THE WORLD! ALL MODELS WE OFFER ARE CUTTING-EDGE PRODUCTS ON THE MARKET. WHEN DEVELOPING CHANSON®, THE GREATEST EMPHASIS WAS PLACED ON ITS SIMPLE MANIPULATION AND INSTALLATION. IT IS SO SIMPLE THAT ANYONE CAN DO IT!
  • Page 5 AFTER THE PROCESS OF ELECTROLYSIS, CALCIUM, MAGNESIUM, SODIUM, POTASSIUM, AND OTHER MINERALS ARE DRAWN BY THE NEGATIVE POLE (ALKALINE) , AND SULPHURIC ACID AND SULPHUR ARE DRAWN BY THE POSITIVE POLE (ACIDIC) . DUE TO AN INCREASE OF HYDROGEN IONS (H+ ) ACIDIC WATER IS PRODUCED.
  • Page 6 WATER IONS UNDER ELECTROLYSIS PROCESS: NEGATIVE POLE: POSITIVE POLE: 2 H2O => 2 H2+ O2 2 H2O => H3O+ + OH- 2 H3O+ + 2E- => H2 + 2 H2O 4 OH- => 2E- + O2 + 2 H2O POSITIVELY CHARGED IONS ARE DRAWN BY THE NEGATIVE POLE TO FORM “REDUCED (ALKALINE) WATER” WHERE AVAILABLE ALKALINE MINERALS FROM SOURCE WATER ARE GATHERED.
  • Page 7 ALKALINE WATER IMPROVES THE TASTE OF FOOD AND IS SUITABLE FOR ALL TYPES OF FOOD PREPARATION AND COOKING; ACIDIC WATER IS SUITABLE FOR USE IN BEAUTY SALONS, TO WASH YOUR FACE AND OTHER ANTIBACTERIAL PURPOSES. BENEFITS OF OUR IONIZERS CHOICE OF PH VALUE FROM 2.4 TO 11.7*; AUTOMATIC DETECTION OF EXCESSIVE WATER FLOW AND TEMPERATURE SENSOR FOR IONIZER PROTECTION;...
  • Page 8 FILTERED ACID WATER ALKALINE WATER WATER pH 2,5- 4 pH 5,5 pH 7,0 pH 8,5 pH 9,0 pH 9,5 pH 11+ x Antibacterial x Plant watering x pH neutral x Optimal for first x Suitable for x Everyday x Fruit and x Sterilization x Beauty use x Medication...
  • Page 9: Product Description

    PRODUCT DESCRIPTION CONSOLE UNIT FRONT VIEW DISPLAY DEVICE FRONT PANEL SIDLE FLOW CONTROL VALVE DEVICE TOUCH CONTROL PANEL IONIZED WATER OUTLET BACK VIEW MINERAL PORT PJ-7000 FILTER PANEL (A1 SILVER) MOUNTING HOLES POWER CORD “Your path to healthy water”...
  • Page 10 BOTTOM VIEW DRAIN FLOW REGULATOR VALVE SOFTWARE UPDATE CONNECTOR FUSE DRAIN WATER OUTLET SOURCE WATER INLET AC SOCKET...
  • Page 11 INSTALLATION ACCESSORY KIT ACCESSORIES PH REAGENT DROPS KIT (PH REAGENT DROPS, FLEXIBLE OUTLET TUBE PH TESTING BOTTLE, COLOUR CHART) PRESSURE REDUCER (Ø 1/4“ QUICK CONNECT) * AC POWER CABLE ACCCESORIES FOR WALLMOUNT MINERAL INSERT BASKET – ONE INSTALLED IN THE DEVICE 100 CM TUBE (Ø...
  • Page 12: Installation

    BASIC INSTALLATION SCHEME AC POWER CABLE SOURCE WATER INLET FROM PRE-FILTRATION DRAIN OUTLET IONIZED WATER OUTLET DEVICE FRONT PANEL PRE-FILTRATTION (PRE-FILTRATION SYSTEM IS OPTIONAL EQUIPMENT AND IS NOT PART OF THE IONIZER PACKAGE ) SOURCE WATER INLET...
  • Page 13 FAUCET DIVERTER INSTALLATION METHOD FAUCET DIVERTER INSTALLATION REMOVE AERARTOR SLIDE 1/4“ TUBE OVER THE BARBED (TIP OF THE FAUCET ). WATER CONNECTION ON THE FAUCET DIVERTER. IT MUST GO IN AT LEAST 12MM. TIGHTEN WITH HOSE CLAMP. MAKE SURE YOU HAVE THE FAUCET USE PLIERS TO MAKE SURE THE DIVERTER WITH THE RUBBER GASKET DIVERTER IS TIGHTENED.
  • Page 14 WATER INLET TUBE CONNECTION FLEXIBLE SPOUT INSTALATION TAKE THE END OF THE TUBE CONNECTED TO THE SCREW THE FLEXIBLE SPOUT FAUCET DIVERTER AND INSERT IT INTO WATER INLET INTO THE ROTATING NECK OF QUICK CONNECT WHICH IS PLACED AT THE BACK OF THE IONIZER PLACED AT THE TOP THE DEVICE (MARKED AS IN AT THE BOTTOM) .
  • Page 15 INSTALLATION METHOD WITH DIRECT CONNECTION TO WATER SUPPLY LINE CONNECTION TO THE WATER SOURCE FIND THE OUTLET OF COLD WATER SUPPLY. TO CONNECT THE DEVICE TO THE COLD WATER PIPE IT IS RECOMMENDED TO USE AN ANGLE VALVE (THE SAME AS FOR CONNECTING DISHWASHER OR WASHING MACHINE) A SHUT-OFF VALVE (CONTACT YOUR DEALER FOR MORE INFORMATION) .
  • Page 16 WATER OUTLET TUBE CONNECTION CONNECT THE 1/4“ TUBE TO THE WATER OUTLET. THE OTHER END INSERT INTO THE ACID WATER OUTLET QUICK CONNECT WHICH IS PLACED AT THE BACK OF THE DEVICE (MARKED AS OUT AT THE BOTTOM) . PUSH THE TUBE AS FAR AS YOU CAN, IT SHOULD GO IN ABOUT 16MM.
  • Page 17: Product Usage

    PRODUCT USAGE TOUCH PANEL DESCRIPTION “Your path to healthy water”...
  • Page 18 POWER (ON/OFF) TURNS THE DEVICE ON AND OFF STRONG ALKALINE WATER (HIGH ALKALINE) IDEAL FOR WASHING FRUIT AND VEGETABLES LEVEL 3 ALKALINE WATER ( ALKALINE 3) IDEAL FOR DAILY DRINKING, STRESS REDUCTION AND REPLENISHMENT OF MINERALS LEVEL 2 ALKALINE WATER (ALKALINE 2) IDEAL FOR DAILY DRINKING, COOKING AND BAKING LEVEL 1 ALKALINE WATER (ALKALINE 1) IDEAL FOR DAILY DRINKING.
  • Page 19 LCD SCREEN Filtered Acidic FEATURES Filtered Acidic Filtered Acidic Filtered Acidic ALKALINE WATER LEVEL INDICATOR LOW WATER FLOW INDICATOR FILTERED WATER INDICATOR IF THIS SYMBOL APPEARS, THE DEVICE IS UNABLE TO FIND A SOURCE OF ACIDIC WATER LEVEL INDICATOR WATER OR THE WATER FLOW IS TOO LOW. FLOW RATE VOLUME ICON FILTER LIFE INDICATOR - COUNTER...
  • Page 20: Instructions

    INSTRUCTIONS PLUG THE POWER CORD INTO THE POWER OUTLET PLUG THE POWER CORD INTO THE POWER OUTLET. YOU´LL NOTICE THAT THE LCD SCREET LIGHTS UP AND CHANGES IN 7 DIFFERENT COLOURS WHILE MAKING A PROMPT SOUND. BY PROMPT SOUND THE DEVICE INDICATES IT IS READY IN STAND-BY MODE WHICH LASTS FOR ABOUT 1 MINUTE. IF NO STEPS ARE TAKEN FOR THE IONIZED WATER TO BE PRODUCED (“POWER”) BUTTON OR NO OTHER ACTION TAKES PLACE, THE DEVICE WILL GO INTO SLEEP MODE.
  • Page 21 DRAINAGE KNOB POINTING TO “MIN” DRAINAGE KNOB POINTING TO “MAX“ MINERAL PORT: THIS WILL ALLOW YOU TO ADD MINERALS TO IMPROVE THE QUALITY OF THE WATER AND TO INCREASE/DECREASE THE MAXIMUM ATTAINABLE PARAMETRES IN THE PROCESS OF WATER IONIZATION. REMOVE THE CAP OF THE MINERAL BASKET PORT TURNING IT COUNTER CLOCKWISE; FILL THE BASKET WITH A MINERAL (CALCIUM, MAGNESIUM, HIMALAYAN ROCK SALT) ;...
  • Page 22 SETTINGS LOCK OPTION SELECT THE DESIRED WATER LEVEL YOU WANT TO LOCK AND PRESS AND HOLD THE BUTTON FOR Filtered Acidic 3 SECONDS. YOU´LL HEAR A VOICE PROMPT INDICATING THAT THE OPTION HAS BEEN ACTIVATED AND YOU´LL SEE THE ICON ON THE SCREEN. TO UNLOCK, PRESS AND HOLD THE BUTTON AGAIN FOR 3 SECONDS AND YOU´LL HEAR A VOICE PROMPT INDICATING THE OPTION HAS BEEN DEACTIVATED.
  • Page 23 PH VALUE ADJUSTMENT PRESS AND HOLD THE BUTTON FOR 5 SECONDS TO ACCESS THE BACK MENU SETTING. PRESS THE Filtered Acidic DESIRED WATER LEVEL TO BE MODIFIED AND THEN PRESS THE “+” OR “-“ TO CHANGE THE PARAMETER. PRESS “ENTER” BUTTON TO SAVE THE SELECTION. REPEAT AT ALL THE WATER LEVELS THAT YOU WANT TO MODIFY.
  • Page 24 FILTER COUNTER RESET PRESS AND HOLD THE BUTTON FOR 5 SECONDS TO ACCESS THE BACK MENU SETTING. PRESS UNTIL YOU SEE A “CLEAN” OPTION ON THE SCREEN. PRESS AND THE BUTTONS AT THE SAME TIME. YOU´LL NOTICE THAT THE FILTER COUNT WILL GO BACK TO 9,000 LITRES AND THE GRIND WILL BE FULL AGAIN.
  • Page 25 BY USING LOW-QUALITY MINERALS YOU CAN DAMAGE THE IONIZER, WHICH CAN LEAD TO LOSS OF WARRANTY. DO NOT USE HIMALAYAN ROCK SALT OR OTHER MINERALS WITH ANY DEVICES EXCEPT WITH CHANSON MIRACLE MAX OR MIRACLE MAX ROYALE DO NOT USE ORDINARY TABLE SALT! IF THE SALT DOES NOT DISSOLVE COMPLETELY DURING THE PROCESS OF WATER PRODUCTION, EMPTY THE MINERAL BASKET IN THE PORT, CLEAN IT SO THERE ARE NO RESIDUES LEFT AND PLACE IT BACK TO THE DEVICE.
  • Page 26: Ionizer Care

    IT IS RECOMMENDED TO PERFORM SERVICE CLEANING EVERY 2 MONTHS TO MAINTAIN YOUR WATER IONIZER AT BEST PERFORMANCE AND TO PREVENT CALCIUM BUILTUP INSIDE ELECTROBATH. PLEASE REFER TO THE INSTRUCTION ON THE CHANSON C-CLEAN KIT WHEN PERFORMING SERVICE CLEAN. CLEANING IS SIMPLE AND WITHOUT ADDITIONAL ACTIONS REMOVE THE SIDE PANEL OF THE CONSOLE UNIT PLACED UNDER THE KITCHEN DESK AND REMOVE „PJ7000“...
  • Page 27 FOR ACTIVATION PRESS AND HOLD „MODE“ BUTTON. WHILE IN THE „CLEAN“ MENU SCREEN, PRESS AND ONCE YOU ARE IN MAIN MENU PRESS „ENTER“ BUTTON HOLD „POWER“ BUTTON FOR 5 SECS. TO ACTIVATE THE TO GO TO THE „CLEAN“ MENU. CITRIC CLEANING PROCESS. SERVICE CLEAN WILL TAKE 35 MINUTES (2.129 SECS.) ONCE SERVICE CLEAN IS FINNISHED REMOVE CLEANING CARTRIDGE AND INSERT „PJ7000“...
  • Page 28: How To Change The Filter

    HOW TO CHANGE THE FILTER LOOKING AT THE IONIZER FROM UNLOCK THE FILTER BY TURNING IT THE FRONT, REMOVE THE LEFT PANEL ANTICLOCKWISE BY SLIDING IT UPWARDS. REMOVE THE FILTER INSERT THE NEW FILTER...
  • Page 29 LOCK THE NEW FILTER BY TURNING IT SLIDE THE PANEL DOWNWARDS ANTICLOCKWISE TO ITS ORIGINAL PLACE DO THE FILTER SERVICE RESET (SEE FILTER COUNT RESET INSTRUCTIONS, P. 24) “Your path to healthy water”...
  • Page 30: Warning

    WARNING IT IS ESSENTIAL TO FOLLOW THE INSTRUCTIONS IT IS IMPORTANT TO MAKE SURE TO CLOSE ALL WATER SUPPLIES AND TO UNPLUG THE IONIZER FROM POWER OUTLET IF YOU WILL NOT BE USING IT FOR AN EXTENDED PERIOD OF TIME. DO NOT PLUG AND UNPLUG THE IONIZER FROM THE POWER OUTLET REPEATEDLY.
  • Page 31 DO NOT PLUG THE IONIZER IF ELECTRICAL SOCKET ON THE IONIZER OR POWER OUTLET ARE LOOSE. THIS WAY YOU WILL AVOID ELECTRICAL DAMAGE OR FIRE. DO NOT TOUCH THE POWER CORD, ELECTRICAL SOCKET OR POWER OUTLET WITH WET HANDS TO AVOID ELECTRICAL SHOCK OR FIRE. DO NOT BEND OR PINCH POWER CORD OR PLACE UNDER HEAVY OBJECTS THAT MIGHT DAMAGE IT.
  • Page 32 IF THERE IS AN UNUSUAL SITUATION LIKE SMOKE OR WATER LEAKAGE FROM THE DEVICE, UNPLUG IT FROM THE POWER AND TURN OFF THE WATER VALVE. DO NOT USE ALKALINE WATER TO SWALLOW MEDICINE. DO NOT DRINK ACIDIC WATER (PH VALUE LOWER THAN 7.0) . DO NOT USE IONIZER FOR UNSUITABLE WATER –...
  • Page 33: Troubleshooting

    TROUBLESHOOTING PROBLEM CAUSE SOLUTION Internal leak from device Find out where the leak is coming from. Contact your dealer for assistance. Remove the tube and check that the shape is round Check fitting and tube to identify where and the cut is straight and not at an angle and Leak from inlet or outlet fitting exactly the leak is coming from.
  • Page 34 Making acid water might produce Bleach smell from acid water hypochlorus acid which is what gives the The smell is harmless to the skin. water its bleachy smell. The ionization process concentrates the This is harmless. You can use the water. calcium in the water.
  • Page 35 This is normal as there will be still water inside the ionizer after being turned off, especially from the dra- Water dripping from drain outlet after Verify if it stops after a few seconds after in. If a long time has passed after using the ionizer turning the ionizer off.
  • Page 36: Specifications

    SPECIFICATIONS ITEM TOP COUNTER WATER IONIZER MODEL MIRACLE MAX PLUS RATED VOLTAGE/FREQUENCY AC 100 – 240V/ 50-60 HZ IONIZER DIMENSIONS 247 × 157 × 335 (WIDTH X DEPTH X HEIGHT IN MM) POWER 175W MAXIMUM WATER PRESSURE 8 – 70 PSI WATER TEMPERATURE 5 –...